CoChat

VAP-33 localizes to both an intracellular vesicle population and with occludin at the tight junction

Lapierre, Lynne A., Tuma, Pamela L., Navarre, Jennifer, Goldenring, James R., Anderson, James M. · 1999 · Journal of Cell Science
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Tight junctions create a regulated intercellular seal between epithelial and endothelial cells and also establish polarity between plasma membrane domains within the cell. Tight junctions have also been implicated in many other cellular functions, including cell signaling and growth regulation, but they have yet to be directly implicated in vesicle movement. Occludin is a transmembrane protein located at tight junctions and is known to interact with other tight junction proteins, including ZO-1. To investigate occludin’s role in other cellular functions we performed a yeast two-hybrid screen using the cytoplasmic C terminus of occludin and a human liver cDNA library. From this screen we identified VAP-33 which was initially cloned from Aplysia by its ability to interact with VAMP/synaptobrevin and thus was implicated in vesicle docking/fusion. Extraction characteristics indicated that VAP-33 was an integral membrane protein. Antibodies to the human VAP-33 co-localized with occludin at the tight junction in many tissues and tissue culture cell lines. Subcellular fractionation of liver demonstrated that 83% of VAP-33 co-isolated with occludin and DPPIV in a plasma membrane fraction and 14% fractionated in a vesicular pool. Thus, both immunofluorescence and fractionation data suggest that VAP-33 is present in two distinct pools in the cells. In further support of this conclusion, a GFP-VAP-33 chimera also distributed to two sites within MDCK cells and interestingly shifted occludin’s localization basally. Since VAP-33 has previously been implicated in vesicle docking/fusion, our results suggest that tight junctions may participate in vesicle targeting at the plasma membrane or alternatively VAP-33 may regulate the localization of occludin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1242/jcs.112.21.3723

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Lapierre, L. A., Tuma, P. L., Navarre, J., Goldenring, J. R., & Anderson, J. M.
Venue
Journal of Cell Science
Published
1999-11-01
Volume
112
Issue
21
Pages
3723-3732
ISSN
  • 0021-9533 (ISSN-L)
  • 1477-9137
OpenAlex
W2125159364
Cited by
106
References
2
FWCI
3.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.