Optimizing live-cell fluorescence imaging conditions to minimize phototoxicity
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Fluorescence illumination can cause phototoxicity that negatively affects living samples. This study demonstrates that much of the phototoxicity and photobleaching experienced with live-cell fluorescence imaging occurs as a result of ‘illumination overhead’ (IO). This occurs when a sample is illuminated but fluorescence emission is not being captured by the microscope camera. Several technological advancements have been developed, including fast-switching LED lamps and transistor–transistor logic (TTL) circuits, to diminish phototoxicity caused by IO. These advancements are not standard features on most microscopes and many biologists are unaware of their necessity for live-cell imaging. IO is particularly problematic when imaging rapid processes that require short exposure times. This study presents a workflow to optimize imaging conditions for measuring both slow and dynamic processes while minimizing phototoxicity on any standard microscope. The workflow includes a guide on how to (1) determine the maximum image exposure time for a dynamic process, (2) optimize excitation light intensity and (3) assess cell health with mitochondrial markers. This article has an associated First Person interview with the first author of the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fission and selective fusion govern mitochondrial segregation and elimination by autophagy
Twig, G., Elorza, A., Molina, A. J. A., Mohamed, H., Wikstrom, J. D., Walzer, G., Stiles, L., Haigh, S. E., Katz, S., Las, G., et al. (2008) · The EMBO Journal · doi:10.1038/sj.emboj.7601963 · Cited by 3,082 · cited 1×
“Mitochondria are much less dynamic than lysosomes (Twig et al., 2008).”
BackgroundApplying systems-level spectral imaging and analysis to reveal the organelle interactome
Valm, A. M., Cohen, S., Legant, W. R., Melunis, J., Hershberg, U., Wait, E., Cohen, A. R., Davidson, M. W., Betzig, E., & Lippincott-Schwartz, J. (2017) · Nature · doi:10.1038/nature22369 · Cited by 1,113
Choi, C. K., Vicente-Manzanares, M., Zareno, J., Whitmore, L. A., Mogilner, A., & Horwitz, A. R. (2008) · Nature Cell Biology · doi:10.1038/ncb1763 · Cited by 797
Stepanova, T., Slemmer, J., Hoogenraad, C. C., Lansbergen, G., Dortland, B., De Zeeuw, C. I., Grosveld, F., van Cappellen, G., Akhmanova, A., & Galjart, N. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-07-02655.2003 · Cited by 698
Thorpe, G. W., Fong, C. S., Alic, N., Higgins, V. J., & Dawes, I. W. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0305888101 · Cited by 450
Mammalian end binding proteins control persistent microtubule growth
Komarova, Y., De Groot, C. O., Grigoriev, I., Gouveia, S. M., Munteanu, E. L., Schober, J. M., Honnappa, S., Buey, R. M., Hoogenraad, C. C., Dogterom, M., et al. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200807179 · Cited by 387 · cited 1×
“Importantly, the mean and standard deviation of EB3 speed was found to be identical between raw and filtered data, and in line with previously published results (Komarova et al., 2009; Stepanova et al., 2003).”
ResultBright monomeric near-infrared fluorescent proteins as tags and biosensors for multiscale imaging
Shcherbakova, D. M., Baloban, M., Emelyanov, A. V., Brenowitz, M., Guo, P., & Verkhusha, V. V. (2016) · Nature Communications · doi:10.1038/ncomms12405 · Cited by 312
Cited by
Tutorial: guidance for quantitative confocal microscopy
Jonkman, J., Brown, C. M., Wright, G. D., Anderson, K. I., & North, A. J. (2020) · Nature Protocols · doi:10.1038/s41596-020-0313-9 · Cited by 401
Self-citationQiao, C., Li, D., Liu, Y., Zhang, S., Liu, K., Liu, C., Guo, Y., Jiang, T., Fang, C., Li, N., et al. (2023) · Nature Biotechnology · doi:10.1038/s41587-022-01471-3 · Cited by 214
“Moreover, some cGAS-DNA condensates moved directionally over long ranges (Supplementary Video 11), during which the ER tubules were reshaped to retain the contacts with moving cGAS-DNA condensates (Fig.”
BackgroundInfluentialPresent Application and Perspectives of Organoid Imaging Technology
Fei, K., Zhang, J., Yuan, J., & Xiao, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030121 · Cited by 65
“The effective strategy to reduce photobleaching and phototoxicity is to minimize the excitation light dose [73,74].”
BackgroundLiu, T., Liu, J., Li, D., & Tan, S. (2025) · Nature Communications · doi:10.1038/s41467-025-60093-w · Cited by 35
Ohno, H., Nishimura, T., Kainoh, K., Ohashi, Y., Onodera, N., Kano, M., Sari, L. N., Masuda, M., Tamura, Y., Nishino, T., et al. (2026) · The FEBS Journal · doi:10.1111/febs.70286 · Cited by 2
Ohno, H., Nishimura, T., Kainoh, K., Ohashi, Y., Onodera, N., Kano, M., Sari, L. N., Masuda, M., Tamura, Y., Hayashi, Y., et al. (2024) · doi:10.1101/2024.03.01.582671 · Cited by 2
Metadata
- Authors
- Kiepas, A., Voorand, E., Mubaid, F., Siegel, P. M., & Brown, C. M.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 2020-02-15
- Volume
- 133
- Issue
- 4
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W3000766642
- Cited by
- 98
- References
- 7
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.