A method for deriving displacement data during cyclical movement using an inertial sensor
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
SUMMARY: Biomechanical studies often employ optical motion capture systems for the determination of the position of an object in a room-based coordinate system. This is not ideal for many types of study in locomotion since only a few strides may be collected per `trial', and outdoor experiments are difficult with some systems. Here, we report and evaluate a novel approach that enables the user to determine linear displacements of a proprietary orientation sensor during cyclical movement. This makes experiments outside the constraints of the laboratory possible, for example to measure mechanical energy fluctuations of the centre of mass during over-ground locomotion. Commercial orientation sensors based on inertial sensing are small and lightweight and provide a theoretical framework for determining position from acceleration. In practice,the integration process is difficult to implement because of integration errors, integration constants and the necessity to determine the orientation of the measured accelerations. Here, by working within the constraints of cyclical movements, we report and evaluate a method for determining orientation and relative position using a modified version of a commercial inertial orientation sensor that combines accelerometers, gyroscopes and magnetometers, thus giving a full set of movement parameters (displacement,velocity and acceleration in three dimensions). The 35 g sensor was attached over the spine of a horse exercising on a treadmill. During canter locomotion(9.0 m s-1), the amplitudes of trunk movement in the x(craniocaudal), y (mediolateral) and z (dorsoventral)directions were 99.6, 57.9 and 140.2 mm, respectively. Comparing sensor displacement values with optical motion capture values for individual strides,the sensor had a median error (25th, 75th percentile) in the x, y and z directions of 0.1 (–9.7, +10.8), –3.8(–15.5, +13.7) and –0.1 (–6.3, +7.1) mm, respectively. High-pass filtering of the displacement data effectively separated non-cyclical from cyclical components of the movement and reduced the interquartile ranges of the errors considerably to (–3.6, 6.2),(–4.0, 3.8) and (–4.5, 5.1) for x, y and z displacement, respectively, during canter locomotion. This corresponds to (–3.2, 5.5)%, (–6.7, 6.3)% and (–3.3, 3.7)%of the range of motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cavagna, G. A. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.39.1.174 · Cited by 624 · cited 3×
“an individual performs against the environment that results in changes in the potential energy (Ep) and kinetic energy (Ek) of the centre of mass (CoM), represents a major component of the mechanical work of locomotion (Cavagna, 1975) and is often evaluated as a measure of locomotor efficiency on different surfaces (F…”
BackgroundInfluentialRunning in the real world: adjusting leg stiffness for different surfaces
Ferris, D. P., Louie, M., & Farley, C. T. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0388 · Cited by 594 · cited 2×
“an individual performs against the environment that results in changes in the potential energy (Ep) and kinetic energy (Ek) of the centre of mass (CoM), represents a major component of the mechanical work of locomotion (Cavagna, 1975) and is often evaluated as a measure of locomotor efficiency on different surfaces (F…”
BackgroundA kinematic comparison of overground and treadmill running
NIGG, B. M., DE BOER, R. W., & FISHER, V. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199501000-00018 · Cited by 258 · cited 1×
“Another disadvantage is the differences between treadmill and over-ground locomotion that have been reported for both horses and humans (Elliott and Blanksby, 1976; Nigg et al., 1995).”
BackgroundThe relationship between mechanical work and energy expenditure of locomotion in horses
Minetti, A. E., Ardigò, L. P., Reinach, E., & Saibene, F. (1999) · Journal of Experimental Biology · doi:10.1242/jeb.202.17.2329 · Cited by 228
Accuracy of non-differential GPS for the determination of speed over ground
Witte, T. H., & Wilson, A. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.031 · Cited by 222
Self-citationKinematics of treadmill versus overground locomotion in horses
Buchner, H. H. F., Savelberg, H. H. C. M., Schamhardt, H. C., Merkens, H. W., & Barneveld, A. (1994) · Veterinary Quarterly · doi:10.1080/01652176.1994.9694509 · Cited by 179 · cited 2×
“In the horse, when compared to over-ground locomotion, treadmill locomotion displays several key mechanical differences including reduced vertical trunk displacement and increased stride length (Barrey et al., 1993; Buchner et al., 1994b).”
BackgroundMethodDetermination of peak vertical ground reaction force from duty factor in the horse (Equus caballus)
Witte, T. H., Knill, K., & Wilson, A. M. (2004) · Journal of Experimental Biology · doi:10.1242/jeb.01182 · Cited by 172 · cited 3×
“This system is accurate to within 2·ms (less than an inertial sensor sample) across all speeds and gaits on a hard surface (Witte et al., 2004).”
BackgroundMethodSelf-citationA cinematographic analysis of overground and treadmill running by males and females
Elliott, B. C., & BLANKSBY, B. A. (1976) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197600820-00013 · Cited by 126
A catapult action for rapid limb protraction
Wilson, A. M., Watson, J. C., & Lichtwark, G. A. (2003) · Nature · doi:10.1038/421035a · Cited by 126 · cited 1×
“A good estimate of CoM displacement and velocity can be gained from overall trunk movement since limb movement is out of phase in the majority of bipedal and quadrupedal gaits and changes of potential energy of the limbs are small (data from Wilson et al., 2003).”
BackgroundSelf-citationHedrick, T. L., Usherwood, J. R., & Biewener, A. A. (2004) · Journal of Experimental Biology · doi:10.1242/jeb.00933 · Cited by 118 · cited 1×
“Accelerometer orientation has previously been determined in two ways; by optical motion capture systems (Hedrick et al., 2004), which encounter the inherent problems discussed above, and by angular rate gyroscopes.”
BackgroundStride Characteristics of Overground versus Treadmill Locomotion in the Saddle Horse
Barrey, É., Galloux, P., Valette, J.-P., et al. (1993) · Cells Tissues Organs · doi:10.1159/000147427 · Cited by 106 · cited 1×
“In the horse, when compared to over-ground locomotion, treadmill locomotion displays several key mechanical differences including reduced vertical trunk displacement and increased stride length (Barrey et al., 1993; Buchner et al., 1994b).”
BackgroundTesio, L., Lanzi, D., & Detrembleur, C. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00081-8 · Cited by 73 · cited 2×
“, 1998), in locomotion with prosthetic limbs (Skinner and Effeney, 1985; Tesio et al., 1998) or to justify gait choice (Minetti et al.”
Background
Cited by
WILSON, R. P., WHITE, C. R., QUINTANA, F., HALSEY, L. G., LIEBSCH, N., MARTIN, G. R., & BUTLER, P. J. (2006) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2006.01127.x · Cited by 797
Gleiss, A. C., Wilson, R. P., & Shepard, E. L. C. (2011) · Methods in Ecology and Evolution · doi:10.1111/j.2041-210x.2010.00057.x · Cited by 472
Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107
Metadata
- Authors
- Pfau, T., Witte, T. H., & Wilson, A. M.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 2005-07-01
- Volume
- 208
- Issue
- 13
- Pages
- 2503-2514
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2120087301
- Cited by
- 223
- References
- 12
- FWCI
- 14.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.