Cited by 107Inertial Sensor and NavigationContext-Aware Activity Recognition SystemsSports Dynamics and Biomechanics

Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion

Godwin, Alison, Agnew, Michael, Stevenson, Joan·2009·Journal of Biomechanical Engineering

Abstract

Inertial motion sensors (IMSs) combine three sensors to produce a reportedly stable and accurate orientation estimate in three dimensions. Although accuracy has been reported within the range of 2 deg of error by manufacturers, the sensors are rarely tested in the challenging motion present in human motion. Their accuracy was tested in static, quasistatic, and dynamic situations against gold-standard Vicon camera data. It was found that static and quasistatic rms error was even less than manufacturers' technical specifications. Quasistatic rms error was minimal at 0.3 deg (+/-0.15 deg SD) on the roll axis, 0.29 deg (+/-0.20 deg SD) on the pitch axis, and 0.73 deg (+/-0.81 deg SD) on the yaw axis. The dynamic rms error was between 1.9 deg and 3.5 deg on the main axes of motion but it increased considerably on off-axis during planar pendulum motion. Complex arm motion in the forward reaching plane proved to be a greater challenge for the sensors to track but results are arguably better than previously reported studies considering the large range of motion used.

Integrity signals

Registry

Crossref · 10.1115/1.4000109

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Godwin, A., Agnew, M., & Stevenson, J.
Affiliations
  • Laurentian University (CA)
  • Virginia Tech (US)
  • Queen's University (CA)
Venue
Journal of Biomechanical Engineering
Published
2009-10-16
Volume
131
Issue
11
Pages
114501-114501
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W1986624256
Cited by
107
References
20
Citations by year
2026: 3 · 2025: 6 · 2024: 3 · 2023: 3 · 2022: 7 · 2021: 8 · 2020: 10 · 2019: 11 · 2018: 8 · 2017: 7 · 2016: 11 · 2015: 6 · 2014: 9 · 2013: 6 · 2012: 6
FWCI
5.82
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomechanical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
Workplace Safety and Insurance Board
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
Keywords
inertial motion sensors, orientation accuracy, dynamic motion, human motion tracking
MeSH terms
Humans, Motion, Range of Motion, Articular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review