Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Abstract
Inertial motion sensors (IMSs) combine three sensors to produce a reportedly stable and accurate orientation estimate in three dimensions. Although accuracy has been reported within the range of 2 deg of error by manufacturers, the sensors are rarely tested in the challenging motion present in human motion. Their accuracy was tested in static, quasistatic, and dynamic situations against gold-standard Vicon camera data. It was found that static and quasistatic rms error was even less than manufacturers' technical specifications. Quasistatic rms error was minimal at 0.3 deg (+/-0.15 deg SD) on the roll axis, 0.29 deg (+/-0.20 deg SD) on the pitch axis, and 0.73 deg (+/-0.81 deg SD) on the yaw axis. The dynamic rms error was between 1.9 deg and 3.5 deg on the main axes of motion but it increased considerably on off-axis during planar pendulum motion. Complex arm motion in the forward reaching plane proved to be a greater challenge for the sensors to track but results are arguably better than previously reported studies considering the large range of motion used.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neck RMSE results varied between less than 1° and 9°, showing good joint measurement validity.
“RMSE results varied between less than 1° and 9°, showing good joint measurement validity [33,34,37,40,41].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [34]
Trunk validity was similar across all movement planes and axes.
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [34]
Studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table.
“For example, studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table [32,34].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [34]
Cites
Human movement analysis using stereophotogrammetry
Cappozzo, A., Croce, U. D., Leardini, A., & Chiari, L. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.01.010 · Cited by 840 · see citing works
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · see citing works
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588 · see citing works
Human movement analysis using stereophotogrammetryPart 1: theoretical background
Cappozzo, A., DELLACROCE, U., Leardini, A., & Chiari, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 397 · see citing works
A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package
Zhu, R., & Zhou, Z. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827825 · Cited by 390 · see citing works
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356 · see citing works
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aïssaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 315 · see citing works
Inclination measurement of human movement using a 3-D accelerometer with autocalibration
Luinge, H. J., & Veltink, P. H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.822759 · Cited by 307 · see citing works
Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 282 · see citing works
An inertial and magnetic sensor based technique for joint angle measurement
O’Donovan, K. J., Kamnik, R., O'Keeffe, D. T., & Lyons, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.010 · Cited by 281 · see citing works
Joint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 263 · see citing works
A method for deriving displacement data during cyclical movement using an inertial sensor
Pfau, T., Witte, T. H., & Wilson, A. M. (2005) · Journal of Experimental Biology · doi:10.1242/jeb.01658 · Cited by 223 · see citing works
Use of cardan angles to locate rigid bodies in three-dimensional space
Tupling, S. J., & Pierrynowski, M. R. (1987) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441745 · Cited by 128 · see citing works
Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors
Kemp, B., Janssen, A. J. M. W., & van der Kamp, B. (1998) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(98)00053-8 · Cited by 121 · see citing works
Inertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · see citing works
Estimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103 · see citing works
Dynamic accuracy of inertial measurement units during simple pendulum motion
Brodie, M. A. D., Walmsley, A., & Page, W. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802125526 · Cited by 77 · see citing works
Surface electromyography analysis for variable gait
Roetenberg, D., Buurke, J. H., Veltink, P. H., Forner‐Cordero, A., & Hermens, H. J. (2003) · Gait & Posture · doi:10.1016/s0966-6362(03)00005-5 · Cited by 63 · see citing works
Upper limb motion estimation from inertial measurements
Zhou, H., & Hu, H. (2007) · Research Portal (Queen's University Belfast) · Cited by 40 · see citing works
Shoulder joint moment estimation during manual wheelchair propulsion using inertial motion trackers
Aïssaoui, R., Desroches, G., & Boissy, P. (2008) · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318 · see citing works
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96 · see citing works
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65 · see citing works
- Authors
- Godwin, A., Agnew, M., & Stevenson, J.
- Affiliations
- Laurentian University (CA)
- Virginia Tech (US)
- Queen's University (CA)
- ORCID
- Godwin, Alison
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2009-10-16
- Volume
- 131
- Issue
- 11
- Pages
- 114501-114501
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1986624256
- Cited by
- 107
- References
- 20
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 3 · 2023: 3 · 2022: 7 · 2021: 8 · 2020: 10 · 2019: 11 · 2018: 8 · 2017: 7 · 2016: 11 · 2015: 6 · 2014: 9 · 2013: 6 · 2012: 6
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Workplace Safety and Insurance Board
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- inertial motion sensors, orientation accuracy, dynamic motion, human motion tracking
- MeSH terms
- Humans, Motion, Range of Motion, Articular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review