Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The wear, wear debris and functional biological activity of non-crosslinked and moderately crosslinked ultrahigh molecular weight polyethylene (UHMWPE) acetabular cups have been compared when articulating against smooth and intentionally scratched femoral heads. Volumetric wear rates were determined in a hip joint simulator and the debris was isolated from the lubricant and characterized by the percentage number and volumetric concentration as a function of particle size. The volumetric concentration was integrated with the biological activity function determined from in vitro cell culture studies to predict an index of specific biological activity (SBA). The product of specific biological activity and volumetric wear rate was used to determine the index of functional biological activity (FBA). On smooth femoral heads the crosslinked UHMWPE had a 30 per cent lower wear rate, but it had a greater percentage volume of smaller, more biologically active particles, which resulted in a similar index of FBA compared with the non-crosslinked material. On the scratched femoral heads the volumetric wear rate was three times higher for the moderately crosslinked UHMWPE and two times higher for the non-crosslinked UHMWPE compared with the smooth femoral heads. This resulted in a higher wear rate for the moderately crosslinked material on the scratched femoral heads. All the differences in wear rate were statistically significant. There were only small differences in particle volume concentration distributions, and this resulted in similar indices of FBA which were approximately twice the values of those found on the smooth femoral heads. Both materials showed lower wear and FBA than for previously studied aged and oxidized UHMWPE gamma irradiated in air. However, this study did not reveal any advantage in terms of predicted FBA for moderately crosslinked UHMWPE compared with non-crosslinked UHMWPE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Self-citationUnified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
Muratoglu, O. K., Bragdon, C. R., O’Connor, D., Jasty, M., Harris, W. H., Gul, R. M., & Garry, F. J. M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00039-3 · Cited by 455
Macrophages stimulate bone resorption when they phagocytose particles
Murray, D., & Rushton, N. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246303 · Cited by 402
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352
Green, T. R., Fisher, J., Matthews, J. B., Stone, M. H., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200009)53:5<490::aid-jbm7>3.0.co;2-7 · Cited by 310
Self-citationMatthews, J. B., Besong, A. A., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J., & Ingham, E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<296::aid-jbm8>3.0.co;2-9 · Cited by 212
Self-citationTipper, J. L., Ingham, E., Hailey, J. L., Besong, A. A., Fisher, J., Wroblewski, B. M., & Stone, M. H. (2000) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008901302646 · Cited by 193
Self-citationWear of Gamma-Crosslinked Polyethylene Acetabular Cups Against Roughened Femoral Balls
McKellop, H., Shen, F.-W., DiMaio, W., & Lancaster, J. G. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199912000-00008 · Cited by 184
Ries, M. D., Scott, M. L., & Jani, S. (2001) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200100022-00009 · Cited by 101
Cited by
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Self-citationMediators of the inflammatory response to joint replacement devices
Cobelli, N., Scharf, B., Crisi, G. M., Hardin, J., & Santambrogio, L. (2011) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2011.128 · Cited by 196
Metadata
- Authors
- Endo, M., Tipper, J. L., Barton, D. C., Stone, M. H., Ingham, E., & Fisher, J.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2002-02-01
- Volume
- 216
- Issue
- 2
- Pages
- 111-122
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2134104972
- Cited by
- 190
- References
- 10
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.