Current trends in biocompatibility testing
The DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Biocompatibility remains the central theme for biomaterials applications in medicine. It is generally accepted that this term means not only absence of a cytotoxic effect but also positive effects in the sense of biofunctionality, i.e. promotion of biological processes which further the intended aim of the application of a biomaterial. The national and international standards for testing regimes represent a lowest common denominator for such applications and do not necessarily ensure that optimal function will be achieved. The authors' thesis is that biocompatibility testing has scope for extensive development with respect to biofunctionality. The present paper reviews current trends in the in vitro aspects of biocompatibility testing. As well as a critical appraisal of the recent literature, future trends are also stressed, which the authors regard as essential for a meaningful integration of a modern biological approach into new developments in the material sciences. These include the application of modern techniques of cell and molecular biology, the concepts of tissue remodelling, hybrid organ development and encapsulated cell technology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
O'Reilly, M. (1994) · Cell · doi:10.1016/0092-8674(94)90200-3 · Cited by 3,345
Inhibitors of mammalian G1 cyclin-dependent kinases.
Sherr, C. J., & Roberts, J. M. (1995) · Genes & Development · doi:10.1101/gad.9.10.1149 · Cited by 3,243
Leukocyte-endothelial adhesion molecules
Carlos, T., & Harlan, J. (1994) · Blood · doi:10.1182/blood.v84.7.2068.2068 · Cited by 2,701
Folkman, J., & Shing, Y. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)49853-0 · Cited by 2,654
Gratzner, H. G. (1982) · Science · doi:10.1126/science.7123245 · Cited by 2,628
Ames, B. N., Durston, W. E., Yamasaki, E., & Lee, F. D. (1973) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.70.8.2281 · Cited by 2,276
Interleukin-8 as a macrophage-derived mediator of angiogenesis
Koch, A. E., Polverini, P. J., Kunkel, S. L., Harlow, L. A., DiPietro, L. A., Elner, V. M., Elner, S. G., & Strieter, R. M. (1992) · Science · doi:10.1126/science.1281554 · Cited by 2,135
Sherr, C. J. (1993) · Cell · doi:10.1016/0092-8674(93)90636-5 · Cited by 1,960
Rho-stimulated contractility drives the formation of stress fibers and focal adhesions.
Chrzanowska-Wodnicka, M., & Burridge, K. (1996) · The Journal of cell biology · doi:10.1083/jcb.133.6.1403 · Cited by 1,683
Active and Inactive Protein Kinases: Structural Basis for Regulation
Johnson, L. N., Noble, M. E. M., & Owen, D. J. (1996) · Cell · doi:10.1016/s0092-8674(00)81092-2 · Cited by 1,403
Research works printed but not linked: 6
- Williams D. F. Progress in Biomedical Engineering, Definitions in Biomaterials, Vol. 4, 1987, pp. 54 (Elsevier, Amsterdam).
- Kirkpatrick C. J., Dekker A. Quantitative evaluation of cell interaction with biomaterials in-vitro. Adv. Biomater., 1992, 10, 31–41.
- Kirkpatrick C. J. A critical view of current and proposed methodologies for biocompatibility testing: Cytotoxicity in-vitro. Regulatory Affairs, 1992, 4, 13–32.
- Dekker A., Panfil C., Valdor M., Pennartz G., Richter H., Mittermayer Ch., Kirkpatrick C. J. Quantitative methods for in vitro cytotoxicity testing of biomaterials. Cells and Mater., 1994, 4, 101–112.
- Warocquier-Clérout R., Hachom-Nitcheu G. C., Sigot-Luizard M. F. Reliability of human fresh and frozen gingiva explant culture in assessing dental materials cyto-compatibility. Cells and Mater., 1995, 5, 1–14.
- ISO-10993–4 Biological evaluation of medical devices, Part 4: Selection of tests for interactions with blood, 1992, pp. 3, Subsection 6.1.6 (International Standardization Organization, Geneva).
Cited by
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Wang, Y.-X., Robertson, J. L., Spillman, W. B., & Claus, R. O. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000036909.41843.18 · Cited by 357
“In summary, (i) to achieve minimum interfacial free energy, one might increase the polar surface free energy of polymers for potential medical applications; (ii) induction of balance between the hydrophilicity and the hydrophobicity on the surface is a way to enhance biocompatibility, and wettability is one of the mos…”
BackgroundThe biocompatibility of novel starch-based polymers and composites: in vitro studies
Marques, A. P., Reis, R. L., & Hunt, J. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00272-1 · Cited by 347
Biocompatibility and drug delivery systems
Kohane, D. S., & Langer, R. (2010) · Chem. Sci. · doi:10.1039/c0sc00203h · Cited by 307
Gomes, P. S., & Fernandes, M. H. (2011) · Laboratory Animals · doi:10.1258/la.2010.010085 · Cited by 291
Current strategies towards hemocompatible coatings
Werner, C., Maitz, M. F., & Sperling, C. (2007) · Journal of Materials Chemistry · doi:10.1039/b703416b · Cited by 258
Kao, W. J., Lee, D., Schense, J. C., & Hubbell, J. A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200104)55:1<79::aid-jbm110>3.0.co;2-z · Cited by 134
Gomes, M. E., Reis, R. L., Cunha, A. M., Blitterswijk, C. A., & de Bruijn, J. D. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00377-x · Cited by 191
The biocompatibility of resin-modified glass-ionomer cements for dentistry
Nicholson, J. W., & Czarnecka, B. (2008) · Dental Materials · doi:10.1016/j.dental.2008.04.005 · Cited by 162
Implantable enzyme amperometric biosensors
Kotanen, C. N., Moussy, F. G., Carrara, S., & Guiseppi‐Elie, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.016 · Cited by 185
Pariente, J.-L., Kim, B., & Atala, A. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)65251-2 · Cited by 150
Xu, W., Ding, J., Xiao, C., Li, L., Zhuang, X., & Chen, X. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.03.021 · Cited by 152
A novel injectable bioactive bone cement for spinal surgery: A developmental and preclinical study
Li, Y. W., Leong, J. C. Y., Lu, W. W., Luk, K. D. K., Cheung, K., Chiu, P., & Chow, S. P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<164::aid-jbm21>3.0.co;2-r · Cited by 135
Thrivikraman, G., Madras, G., & Basu, B. (2014) · RSC Advances · doi:10.1039/c3ra44483j · Cited by 141
Bioinspired Ice-Binding Materials for Tissue and Organ Cryopreservation
Liu, Z., Zheng, X., & Wang, J. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c00203 · Cited by 133
Correlating macrophage morphology and cytokine production resulting from biomaterial contact
Lee, H., Stachelek, S. J., Tomczyk, N., Finley, M. J., Composto, R. J., & Eckmann, D. M. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34309 · Cited by 123
Ng, W., An, J., & Chee, K.-C. (2024) · Engineering · doi:10.1016/j.eng.2024.01.028 · Cited by 112
Gomes, M. E., & Reis, R. L. (2004) · International Materials Reviews · doi:10.1179/095066004225021918 · Cited by 120
A review on potential toxicity of dental material and screening their biocompatibility
Shahi, S., Özcan, M., Dizaj, S. M., Sharifi, S., Husain, N. A., Eftekhari, A., & Ahmadian, E. (2019) · Toxicology Mechanisms and Methods · doi:10.1080/15376516.2019.1566424 · Cited by 118
Ultrananocrystalline diamond film as an optimal cell interface for biomedical applications
Bajaj, P., Akin, D., Gupta, A. K., Sherman, D., Shi, B., Auciello, O. H., & Bashir, R. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9090-2 · Cited by 125
“The spreading index, which is a function of average cell area per unit cell number, indicates how well the cells will integrate with the host surface (Kirkpatrick et al. 1998).”
BackgroundBiocompatibility of Fe3O4@Au composite magnetic nanoparticles in vitro and in vivo
Li, Y., Liu, Zhong, Y., Zhang, D.-S., Wang, Wang, An, Y., Lin, Gao, & Zhang (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s24596 · Cited by 115
“10 Therefore, the cytotoxicity assay, hemolysis test, micronucleus (MN) assay, and detection of acute toxicity in mice and beagle dogs were introduced to evaluate the biocompatibility of self-assembled Fe 3 O 4 @Au composite MNPs in this research.”
Altankov, G., Thom, V., Groth, T., Jankova, K., Jönsson, G., & Ulbricht, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<219::aid-jbm28>3.0.co;2-f · Cited by 121
Tissue response and biomaterial integration: the efficacy of in vitro methods
Kirkpatrick, C. J., Krump‐Konvalinkova, V., Unger, R. E., Bittinger, F., Otto, M., & Peters, K. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00019-9 · Cited by 115
Self-citationPelegrino, M. T., Lima, B. D. A., Nascimento, M. H. M., Lombello, C. B., Brocchi, M., & Seabra, A. B. (2018) · Polymers · doi:10.3390/polym10040452 · Cited by 87
“The cytotoxicity effects of CS/PL and GSNO-CS/PL hydrogels were evaluated towards Vero cells by MTT-3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay [45,46].”
MethodYang, M., Ding, J., Zhang, Y., Chang, F., Wang, J., Gao, Z., Zhuang, X., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c5tb02479j · Cited by 85
Härtung, T., Aaberge, I. S., Berthold, S., Carlin, G., Charton, E., Coecke, S., Fennrich, S., Fischer, M. J., Gommer, M., Halder, M., et al. (2001) · Alternatives to Laboratory Animals · doi:10.1177/026119290102900203 · Cited by 88
Gallagher, W. M., Lynch, I., Allen, L. T., Miller, I. S., Penney, S. C., O’Connor, D. P., Pennington, S. R., KEENAN, A. K., & Dawson, K. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.040 · Cited by 82
In Vitro Biocompatibility Studies of Antibacterial Quaternary Polymers
Stratton, T. R., Rickus, J. L., & Youngblood, J. P. (2009) · Biomacromolecules · doi:10.1021/bm9005003 · Cited by 71
Wear characteristic and biocompatibility of some polymer composite acetabular cups
Chowdhury, S. K. R., Mishra, A. R., Pradhan, B., & Saha, D. (2003) · Wear · doi:10.1016/s0043-1648(03)00535-0 · Cited by 70
Mamilos, A., Winter, L., Schmitt, V. H., Barsch, F., Grevenstein, D., Wagner, W. L., Babel, M., Keller, K., Schmitt, C., Gürtler, F., et al. (2023) · Cells · doi:10.3390/cells12020276 · Cited by 82
“In this context, it is generally accepted that the macrophage is a central element of the inflammatory response, which is practically universally involved in the tissue reaction to implanted biomaterials [205].”
Rickert, D., Lendlein, A., Peters, I., Moses, M. A., & Franke, R.-P. (2006) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-005-0950-1 · Cited by 66
Marques, A. P., & Reis, R. L. (2005) · Materials Science and Engineering C · doi:10.1016/j.msec.2005.01.013 · Cited by 71
An in vitro pyrogen safety test for immune-stimulating components on surfaces
Hasiwa, M., Kullmann, K., von Aulock, S., Klein, C. L., & Härtung, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.016 · Cited by 60
Self-citationIn vitro and in vivo (cyto)toxicity assays using PVC and LDPE as model materials
van Tienhoven, E. A. E., Korbee, D., Schipper, L. F., Verharen, H. W., & de Jong, W. H. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30679 · Cited by 63
Stangegaard, M., Petronis, Š., Jørgensen, A. M., Christensen, C. B. V., & Dufva, M. (2006) · Lab on a Chip · doi:10.1039/b603379b · Cited by 57
Indirect cytotoxicity evaluation of pseudowollastonite
Dufrane, D., Delloye, C., McKay, I. J., Aza, P. N. D., Aza, S. D., Schneider, Y., & Anseau, M. R. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1021545302732 · Cited by 55
Endothelial cell cultures as a tool in biomaterial research
Kirkpatrick, C. J., Otto, M., van Kooten, T. G., Krump‐Konvalinkova, V., Kriegsmann, J., & Bittinger, F. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008946615663 · Cited by 50
Self-citationIdris, S. B., Dånmark, S., Finne‐Wistrand, A., Arvidson, K., Albertsson, A., Bolstad, A. I., & Mustafa, K. (2010) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911510381368 · Cited by 48
Stangegaard, M., Wang, Z., Kutter, J. P., Dufva, M., & Wolff, A. (2006) · Molecular BioSystems · doi:10.1039/b608239d · Cited by 43
Aerogel-Based Materials in Bone and Cartilage Tissue Engineering—A Review with Future Implications
Lázár, I., Čelko, L., & Menelaou, M. (2023) · Gels · doi:10.3390/gels9090746 · Cited by 43
“Despite this limitation, such assays present a convenient and economical means of analysis, exempt from the complexities of permissions and ethical considerations, and are extensively reviewed in the literature [73,109,110].”
BackgroundSteele, J. G., Johnson, G., McLean, K. M., Beumer, G. J., & Griesser, H. J. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000615)50:4<475::aid-jbm2>3.0.co;2-g · Cited by 58
Marques, A. P., Cardoso-Cruz, H., Coutinho, O. P., & Reis, R. L. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-3580-7 · Cited by 39
Testing the cytotoxicity of metal alloys used as magnetic prosthetic devices
Hopp, M., Rogaschewski, S., & Groth, T. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1022931915709 · Cited by 37
Pieretti, J. C., Rolim, W. R., Ferreira, F. F., Lombello, C. B., Nascimento, M. H. M., & Seabra, A. B. (2019) · Journal of Cluster Science · doi:10.1007/s10876-019-01670-0 · Cited by 35
Perspectives on:In Vitro Evaluation of Biomedical Polymers
Chiellini, E. (2006) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911506064672 · Cited by 44
In vitro methodologies to evaluate biocompatibility: status quo and perspective
Kirkpatrick, C. J., Peters, K., Hermanns, I., Bittinger, F., Krump‐Konvalinkova, V., Fuchs, S., & Unger, R. E. (2005) · ITBM-RBM · doi:10.1016/j.rbmret.2005.04.008 · Cited by 38
Self-citationToward Fully Automated Personalized Orthopedic Treatments: Innovations and Interdisciplinary Gaps
Luo, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11080817 · Cited by 39
“Material biocompatibility has been recognized as the predominant factor behind the long-term failure of orthopedic treatments [202–204].”
BackgroundAbhilash, M. R., Gangadhar, A., Jagadish, K., Chikkamadaiah, M., & Srikantaswamy, S. (2019) · RSC Advances · doi:10.1039/c9ra04978a · Cited by 30
Physical and chemical processing for a human dura mater substitute
Dufrane, D., Cornu, O., Delloye, C., & Schneider, Y. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00027-3 · Cited by 27
“Major aspects of the cell physiology such as growth, metabolic activity (succinate dehydrogenase activity), membrane integrity (neutral red uptake) and absence of necrosis (lactate dehydrogenase in the culture medium) [29,30,45–50] were investigated, by indirect evaluation, following the contact between cells and extr…”
BackgroundOtto, M., Bittinger, F., Kriegsmann, J., & Kirkpatrick, C. J. (2001) · Pathobiology · doi:10.1159/000048771 · Cited by 27
Self-citationRenò, F., Lombardi, F., & Cannas, M. F. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00128-5 · Cited by 25
“After the prosthesis implantation, a specific leukocytes inflammatory response mediated by activated neutrophils (85–90% of granulocytes) [22] occurs and this phenomenon is considered a key step in the healing process [23].”
BackgroundScandia—A potential biomaterial?
Herath, H. M. T. U., Silvio, L. D., & Evans, J. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-4760-1 · Cited by 23
Effects of titanium-based nanotube films on osteoblast behaviorin vitro
Stan, M., Memet, I., Fratila, C., Krasicka‐Cydzik, E., Roman, I., & Dinischiotu, A. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35148 · Cited by 23
Fibroblast interaction with carboxymethylchitosan-based hydrogels
Janvikul, W., Uppanan, P., Thavornyutikarn, B., Prateepasen, R., & Swasdison, S. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-006-0099-5 · Cited by 19
Wear characteristic and biocompatibility of some hydroxyapatite–collagen composite acetabular cups
Chowdhury, S. K. R., Kulkarni, A. C., Basak, A., & Roy, S. (2007) · Wear · doi:10.1016/j.wear.2007.01.023 · Cited by 19
Epoxy networks for medicine applications: Mechanical properties and in vitro biological properties
García, F. G., Leyva, M. E., de Queiroz, A. A. A., & Higa, O. Z. (2009) · Journal of Applied Polymer Science · doi:10.1002/app.29528 · Cited by 21
Peltroche‐Llacsahuanga, H., Schmidt, S., Schnitzler, N., Lütticken, R., & Haase, G. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00468-9 · Cited by 22
Rezaei, S. M., & Ishak, Z. A. M. (2013) · eXPRESS Polymer Letters · doi:10.3144/expresspolymlett.2014.5 · Cited by 18
“monly accepted that this term means not only a lack of cytotoxic effects, but also positive effects in the sense of biofunctionality [2, 3].”
BackgroundJäger, E., Donato, R. K., Perchacz, M., Jäger, A., Surman, F., Höcherl, A., Konefał, R., Donato, K. Z., Venturini, C. G., Bergamo, V. Z., et al. (2015) · RSC Advances · doi:10.1039/c5ra15858c · Cited by 18
Saltepe, B., Bozkurt, E. U., Hacıosmanoğlu, N., & Şeker, U. Ö. Ş. (2019) · ACS Synthetic Biology · doi:10.1021/acssynbio.9b00291 · Cited by 18
Critical fluid shear stress analysis for cell–polymer adhesion
Rocha, A., Hahn, M. S., & Liang, H. Y. (2009) · Journal of Materials Science · doi:10.1007/s10853-009-4004-8 · Cited by 16
Techniques for Assessing the Properties of Advanced Ceramic Materials
Rahman, M., Haider, J., Akter, T., & Hashmi, M. S. J. (2014) · Elsevier eBooks · doi:10.1016/b978-0-08-096532-1.00124-2 · Cited by 24
Santo, M. C. D., Alaimo, A., Rubio, A. P. D., Matteo, R. D., & Pérez, O. E. (2020) · Biochemistry and Biophysics Reports · doi:10.1016/j.bbrep.2020.100842 · Cited by 21
“Cell adhesion and morphology Another parameters to define the cytotoxicity of a biomaterial are both the cell adhesion and morphology, since they are probably the most valuable aspects of the cellular interaction with a biomaterial [4].”
BackgroundSani, N. S., Malek, N. A. N. N., Jemon, K. B., Kadir, M. R. A., & Hamdan, H. (2016) · Journal of Sol-Gel Science and Technology · doi:10.1007/s10971-016-4266-y · Cited by 15
“Therefore, to assess the biocompatibility effects of materials, human dermal fibroblast cells were used in the viability study [29].”
MethodFiroznezhad, M., Rached, R. A., Fulgheri, F., Aroffu, M., Leyva‐Jiménez, F. J., Cádiz‐Gurrea, M. D. L. L., Meloni, M. C., Corrias, F., Escribano‐Ferrer, E., Peris, J., et al. (2023) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2023.122650 · Cited by 13
In Vitro Biocompatibility of CPP-ACP and Fluoride-containing Desensitizers on Human Gingival Cells
López‐García, S., Gironés, J. G., Pecci-Lloret, M., Pecci-Lloret, M., Rodríguez‐Lozano, F. J., & García‐Bernal, D. (2021) · Operative Dentistry · doi:10.2341/20-245-l · Cited by 14
Polymers with tunable toxicity: A reference scale for cytotoxicity testing of biomaterial surfaces
Knetsch, M. L. W., Olthof, N. C., & Koole, L. H. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31212 · Cited by 14
Wanschitz, F., Nell, A., Patruta, S., Wagner, A., & Ewers, R. (2005) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2005.01150.x · Cited by 12
Probing Toxicity of Biomaterials and Biocompatibility Assessment
Basu, B. (2016) · Indian Institute of Metals series · doi:10.1007/978-981-10-3059-8_9 · Cited by 14
Biocompatibility and Tissue Reaction to Biomaterials
(2012) · Elsevier eBooks · doi:10.1016/b978-0-323-08108-5.10006-4 · Cited by 18
In vitro evaluation of acute cytotoxicity of human chemically treated allografts
Dufrane, D., Cornu, O., Verraes, T., Schecroun, N., Banse, X., Schneider, Y., & Delloye, C. (2001) · doi:10.22203/ecm.v001a06 · Cited by 10
Rais, B., Köster, M., Rahim, M. I., Pils, M. C., Seitz, J., Häuser, H., Wirth, D., & Mueller, P. P. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35758 · Cited by 11
Najman, S. J., Stojanović, S., Živković, J. M., Najdanović, J. G., Radenković, M. B., Vasiljevic, P. J., & Ignjatović, N. L. (2023) · Contemporary Materials · doi:10.7251/comen2301001n · Cited by 9
Preclinical Assessment of Living Therapeutic Materials: State-of-Art and Challenges
Desai, K., Mekontso, J. A., Deshpande, K., & Trujillo, S. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c00247 · Cited by 12
“66 − 69 Examples using ex vivo assays for the assessment of LTMs are summarized in Table 2 and discussed, depending on application.”
Schnieders, J., Gbureck, U., Germershaus, O., Kratz, M., Jones, D. B., & Kissel, T. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201200390 · Cited by 9
The Biocompatibility Study of Fe3O4 Magnetic Nanoparticles Used in Tumor Hyperthermia
Zhang, D., & Du, Y. (2006) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2006.334754 · Cited by 9
“However the biomaterials would directly contact with the tissues and cells when they were sent into the body, so their biocompatibility had to be evaluated before they were applied in clinic[2,3].”
BackgroundCell Viability Assessment of PEDOT Conducting Polymer-Coated Microneedles for Skin Sampling
Mokhtar, S. M. A., Derrick‐Roberts, A. L. K., Evans, D., & Strudwick, X. L. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00416 · Cited by 9
Evaluating Biocompatibility: From Classical Techniques to State-of-the-Art Functional Proteomics
Nuño-Soriano, A., Arias‐Hidalgo, C., Montalvillo, E., Góngora, R., Hernández, Á., Juanes‐Velasco, P., & Fuentes, M. (2025) · Nanomaterials · doi:10.3390/nano15131032 · Cited by 8
“In vitro techniques have proved to be highly valuable for biomaterials evaluation, particularly in toxicology, by assessing cell viability, adhesion, proliferation, and biosynthetic activity [58] and other specific tissue hazards.”
Assessing the biocompatibility of a dental composite product.
Pătroi, D., Gociu, M., Prejmerean, C., Colceriu, L., SILAGHI-DUMITRESCU, L., Moldovan, M., & Naicu, V. (2013) · PubMed · Cited by 10
Compatibility of different polymers for cord blood-derived hematopoietic progenitor cells
Ferreira, M. S. V., Labude, N., Piroth, D. M., Jahnen‐Dechent, W., Knüchel, R., Hieronymus, T., Zenke, M., & Neuß, S. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4483-4 · Cited by 8
ICAM-1 expression in vaginal cells as a potential biomarker for inflammatory response
Youn, H., Hong, K., Yoo, J., & Lee, C. H. (2008) · Biomarkers · doi:10.1080/13547500701843338 · Cited by 8
Starch and its Derived Products: Biotechnological and Biomedical Applications
Kennedy, J. F., Knill, C. J., Liu, L., & Panesar, P. S. (2011) · Royal Society of Chemistry eBooks · doi:10.1039/9781849733519-00130 · Cited by 12
Advanced density-based methods for the characterization of materials, binding events, and kinetics
Doan‐Nguyen, T. P., & Crespy, D. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00232e · Cited by 10
Berezhna, L. G., Ivanov, A. E., Leistner, A., Lehmann, A., Viloria-Cols, M., & Jungvid, H. (2013) · Progress in Biomaterials · doi:10.1186/2194-0517-2-4 · Cited by 7
“However, materials that are supposed to be in contact with human organisms or blood plasma must be biocompatible, in particular, concerning their interaction with clotting and complement systems of the blood (Kirkpatrick et al. 1998).”
BackgroundMaximizing Fibroblast Adhesion on Protein-Coated Surfaces Using Microfluidic Cell Printing
Davidoff, S., Au, D., Gale, B. K., Brooks, B. D., & Brooks, A. (2015) · RSC Advances · doi:10.1039/c5ra18673k · Cited by 5
Rabadán-Ros, R., Aznar‐Cervantes, S. D., Mazón, P., Ros-Tárraga, P., Aza, P. N. D., & Meseguer‐Olmo, L. (2017) · Materials · doi:10.3390/ma10040347 · Cited by 6
“In vitro studies are widely employed as preliminary tests to evaluate the biocompatibility of new materials with potential applications in biomedicine [24].”
BackgroundBiocompatibility ofBletilla striataMicrospheres as a Novel Embolic Agent
Luo, S., Song, S., Zheng, C., Wang, Y., Xia, X., Liang, B., & Feng, G. (2015) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2015/840896 · Cited by 6
“The mixed cell cultivation method in vitro involves the culture of medical materials in vitro with various cells to examine the effect on the growth and proliferation of the cells [18, 19].”
MethodGonzaga, F. D. A., de Miranda, T. T., Magalhães, L. M. D., Dutra, W. O., Gollob, K. J., Souza, P. E. A., & Horta, M. C. R. (2016) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33747 · Cited by 6
Biofunctionality and immunocompatibility of starch-based biomaterials
Marques, A. M. P. (2004) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 7
Butnaru, M., Bredetean, O., Macocinschi, D., Dimitriu, C., Knieling, L., & Harabagiu, V. (2012) · InTech eBooks · doi:10.5772/34653 · Cited by 6
“Some local conditions (extent of surgical injury, body reactivity) or properties of the implanted device can trigger a chronic inflammatory evolution (Kirkpatrick et al., 1998).”
BackgroundBiocompatibility of degradable polymers for tissue engineering
Gurav, N., & Silvio, L. D. (2009) · Elsevier eBooks · doi:10.1533/9781845695477.1.61 · Cited by 8
Cell Type-Specific Adhesion and Migration on Laser-Structured Opaque Surfaces
Schaeske, J., Fadeeva, E., Schlie-Wolter, S., Deiwick, A., Chichkov, B. N., Ingendoh‐Tsakmakidis, A., Stiesch, M., & Winkel, A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21228442 · Cited by 5
“So far, early-stage biocompatibility tests still focus on the cytotoxicity of a surface, which is required during approval process, as well as on the adhesion and the proliferation of cells on innovative implant material [41].”
BackgroundSun, X., Song, K., Wang, S., & Sun, K. (2021) · Journal of Superconductivity and Novel Magnetism · doi:10.1007/s10948-021-05818-w · Cited by 5
Risbud, M. V., & Bhonde, R. R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010305)54:3<436::aid-jbm180>3.0.co;2-8 · Cited by 61
Self-citationBiocompatibility of components of a female controlled drug delivery system
Warrier, B. K., Kostoryz, E. L., & Lee, C. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30111 · Cited by 6
Polystyrene surface coated with vitamin E modulates human granulocyte adhesion and MMP-9 release
Renò, F., Lombardi, F., & Cannas, M. F. (2004) · Biomolecular Engineering · doi:10.1016/j.bioeng.2003.11.001 · Cited by 6
“In fact, after the prosthesis implantation, neutrophil granulocytes adhere along with other leukocytes to polymeric artificial surfaces [2] by the adsorbed plasma protein layer [3,4].”
BackgroundJantová, S., Letašiová, S., Theiszová, M., & Palou, M. T. (2009) · Acta Biologica Hungarica · doi:10.1556/abiol.60.2009.1.9 · Cited by 5
Biocompatibility Study of Mn0.5Zn0.5Fe2O4 Magnetic Nanoparticles
Liu, J., Zhang, J., Wang, L., Li, Y. T., & Zhang, D. S. (2011) · Key engineering materials · doi:10.4028/www.scientific.net/kem.483.552 · Cited by 5
“Cancer cells are more radiosensitive when exposed to elevated temperatures [6] However, the biocompatibility of the magnetic nanoparticles needs to be thoroughly evaluated before the materials can be applied in the following study, because of inevitable contact with the cells and the tissues if used in the body in cli…”
Background
Metadata
- Authors
- Kirkpatrick, C. J., Bittinger, F., Wagner, M., Köhler, H., van Kooten, T. G., Klein, C. L., & Otto, M.
- Affiliations
- Johannes Gutenberg University Mainz (DE)
- Johannes Gutenberg University Institute of Pathology Mainz, Germany
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 1998-02
- Volume
- 212
- Issue
- 2
- Pages
- 75-84
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2156732773
- Cited by
- 145
- References
- 83
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 6 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 3 · 2017: 6 · 2016: 7 · 2015: 6 · 2014: 4 · 2013: 4 · 2012: 9
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- biocompatibility testing, biomaterials, biofunctionality, in vitro evaluation, cytotoxicity, tissue remodeling, molecular and cellular biology
- MeSH terms
- Animals, Biocompatible Materials, Cell Adhesion, Cells, Cultured, Cytological Techniques, Cytotoxicity Tests, Immunologic, Forecasting, Humans, Materials Testing, Rheology, Stress, Mechanical, Medical Laboratory Science, Reproducibility of Results, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.