Abstract
The topics of verification and validation have increasingly been discussed in the field of computational biomechanics, and many recent articles have applied these concepts in an attempt to build credibility for models of complex biological systems. Verification and validation are evolving techniques that, if used improperly, can lead to false conclusions about a system under study. In basic science, these erroneous conclusions may lead to failure of a subsequent hypothesis, but they can have more profound effects if the model is designed to predict patient outcomes. While several authors have reviewed verification and validation as they pertain to traditional solid and fluid mechanics, it is the intent of this paper to present them in the context of computational biomechanics. Specifically, the task of model validation will be discussed, with a focus on current techniques. It is hoped that this review will encourage investigators to engage and adopt the verification and validation process in an effort to increase peer acceptance of computational biomechanics models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Software Engineering Economics
Boehm, B. W. (2001) · Pioneers and Their Contributions to Software Engineering · doi:10.1007/978-3-642-48354-7_5 · Cited by 5,981
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Verification, Validation, and Confirmation of Numerical Models in the Earth Sciences
Oreskes, N., Shrader-Frechette, K., & Belitz, K. (1994) · Science · doi:10.1126/science.263.5147.641 · Cited by 3,010
Monte Carlo Strategies in Scientific Computing
Liu, J. S. (2004) · Springer Series in Statistics · doi:10.1007/978-0-387-76371-2 · Cited by 2,690
Verification and Validation in Computational Science and Engineering
Roache, P. J. (1998) · Cited by 2,157
Variational methods for the solution of problems of equilibrium and vibrations
Courant, R. (1943) · Bulletin of the American Mathematical Society · doi:10.1090/s0002-9904-1943-07818-4 · Cited by 1,711
Stiffness and Deflection Analysis of Complex Structures
TURNER, M. J., CLOUGH, R. W., MARTIN, H. C., & TOPP, L. J. (1956) · Journal of the Aeronautical Sciences · doi:10.2514/8.3664 · Cited by 1,565
Monte Carlo Strategies in Scientific Computing
Hesterberg, T. (2002) · Technometrics · doi:10.1198/tech.2002.s85 · Cited by 1,409
Stern, F., Wilson, R. V., Coleman, H. W., & Paterson, E. G. (2001) · Journal of Fluids Engineering · doi:10.1115/1.1412235 · Cited by 935
(2016) · Systems Engineering for Commercial Aircraft · doi:10.4324/9781315611716-18 · Cited by 804
Verification, validation, and predictive capability in computational engineering and physics
Oberkampf, W. L., Trucano, T. G., & Hirsch, C. (2004) · Applied Mechanics Reviews · doi:10.1115/1.1767847 · Cited by 719
Mechanical validation of whole bone composite tibia models
Cristofolini, L., & Viceconti, M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00186-4 · Cited by 609
A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1470171 · Cited by 493
MacNeil, J. A., & Boyd, S. K. (2008) · Bone · doi:10.1016/j.bone.2008.01.017 · Cited by 440
Verification and validation in computational engineering and science: basic concepts
Babuska, I., & Oden, J. T. (2004) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.03.002 · Cited by 376
Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies
Anderson, A. E., Peters, C. L., Tuttle, B. D., & Weiss, J. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1894148 · Cited by 347
Self-citationExtracting clinically relevant data from finite element simulations
Viceconti, M., Olsen, S., Nolte, L.-P., & Burton, K. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.010 · Cited by 342
Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone
Dalstra, M., Huiskes, R., & van Erning, L. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794181 · Cited by 303
Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Self-citationHaut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00305-6 · Cited by 247
Gardiner, J. C., & Weiss, J. A. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00113-x · Cited by 238
Self-citationVerification, validation and sensitivity studies in computational biomechanics
Anderson, A. E., Ellis, B. J., & Weiss, J. A. (2007) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840601160484 · Cited by 237
Self-citationA Three-Dimensional Viscoelastic Model for Cell Deformation with Experimental Verification
Karcher, H., Lammerding, J., Huang, H., Lee, R. T., Kamm, R. D., & Kaazempur-Mofrad, M. R. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74753-5 · Cited by 207
Three-dimensional finite element modeling of ligaments: Technical aspects
Weiss, J. A., Gardiner, J. C., Ellis, B. J., Lujan, T. J., & Phatak, N. S. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.05.006 · Cited by 161
Self-citationExperimental Validation of a Finite Element Model of a Human Cadaveric Tibia
Gray, H. A., Taddei, F., Zavatsky, A. B., Cristofolini, L., & Gill, H. S. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2913335 · Cited by 151
Viceconti, M., Davinelli, M., Taddei, F., & Cappello, A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.030 · Cited by 151
Steele, B. N., Wan, J., Ku, J. P., Hughes, T. J. R., & Taylor, C. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812201 · Cited by 146
Algorithm for model validation: Theory and applications
Sornette, D., Davis, A. B., Ide, K., Vixie, K. R., Писаренко, В. Ф., & Kamm, J. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611677104 · Cited by 144
Veress, A. I., Gullberg, G. T., & Weiss, J. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073677 · Cited by 115
Self-citationAccurate Navier-Stokes results for the hypersonic flow over a spherical nosetip
Blottner, F. G. (1990) · Journal of Spacecraft and Rockets · doi:10.2514/3.26115 · Cited by 112
Verification, validation, and predictive capability in computational engineering and physics.
Oberkampf, W. L., Hirsch, C. J., & Trucano, T. G. (2003) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/918370 · Cited by 94
A computational framework to predict post-treatment outcome for gait-related disorders
Reinbolt, J. A., Haftka, R. T., Chmielewski, T. L., & Fregly, B. J. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.005 · Cited by 67
Yeni, Y. N., Christopherson, G. T., Dong, X. N., Kim, D., & Fyhrie, D. P. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835346 · Cited by 57
Medial collateral ligament insertion site and contact forces in the ACL-deficient knee
Ellis, B. J., Lujan, T. J., Dalton, M. S., & Weiss, J. A. (2006) · Journal of Orthopaedic Research® · doi:10.1002/jor.20102 · Cited by 56
Self-citationNoninvasive Determination of Ligament Strain with Deformable Image Registration
Phatak, N. S., Sun, Q., Kim, S., Parker, D. L., Sanders, R. K., Veress, A. I., Ellis, B. J., & Weiss, J. A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9287-9 · Cited by 47
Self-citationToward Patient-Specific Myocardial Models of the Heart
Sermesant, M., Peyrat, J., Chinchapatnam, P. P., Billet, F., Mansi, T., Rhode, K., Delingette, H., Razavi, R., & Ayache, N. (2008) · Heart Failure Clinics · doi:10.1016/j.hfc.2008.02.014 · Cited by 45
A new method for the automatic mesh generation of bone segments from CT data
Viceconti, M., Zannoni, C., Testi, D., & Cappello, A. (1999) · Journal of Medical Engineering & Technology · doi:10.1080/030919099294339 · Cited by 31
Analysis of left ventricular behaviour in diastole by means of finite element method.
Vinson, C. A., Gibson, D. G., & Yettram, A. L. (1979) · Heart · doi:10.1136/hrt.41.1.60 · Cited by 23
Cited by
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
Self-citationHicks, J. L., Uchida, T. K., Seth, A., Rajagopal, A., & Delp, S. L. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029304 · Cited by 748
Considerations for reporting finite element analysis studies in biomechanics
Erdemir, A., Guess, T. M., Halloran, J., Tadepalli, S. C., & Morrison, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.038 · Cited by 234
“The procedure may include direct validation (experimentation done by model developer where an output from the experiment directly matches the predicted output from the model), and indirect validation (based on data from literature) (Henninger et al., 2010).”
MethodBurkhart, T. A., Andrews, D. M., & Dunning, C. E. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.03.022 · Cited by 222
“Summary Anderson et al. (2007), Cristofolini et al. (2010) and Erdemir et al. (2012), Henninger et al. (2010) and Jones and Wilcox (2008) present an excellent framework regarding validation and verification of lease cite this article as: Burkhart, T.A., et al., Finite element modelin ith…”
BackgroundMethodInfluentialFinite element modeling of soft tissues: Material models, tissue interaction and challenges
Freutel, M., Schmidt, H., Dürselen, L., Ignatius, A., & Galbusera, F. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.01.006 · Cited by 184
“At best the experiment captures the most critical parameters to provide certainty that the inputs to and results from a simulation model accurately define the intended system (Henninger et al., 2010).”
Background
Metadata
- Authors
- Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2009-12-15
- Volume
- 224
- Issue
- 7
- Pages
- 801-812
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2095712753
- Cited by
- 204
- References
- 38
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.