How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840 · cited 1×
“Orientation of the film on the tibial plateau was recorded by placing registration marks on the film in regions that supported only minimal load (Huberti and Hayes, 1984).”
Baratz, M. E., Fu, F. H., & Mengato, R. (1986) · The American Journal of Sports Medicine · doi:10.1177/036354658601400405 · Cited by 830
The strength of the anterior cruciate ligament in humans and Rhesus monkeys
Noyes, F., & Grood, E. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658080-00006 · Cited by 826 · cited 1×
“Therefore, using the modulus of 111726MPa (Noyes and Grood, 1976), the initial stiffness value for the transverse ligament was approximated to be 200 N/mm.”
Fukubayashi, T., & Kurosawa, H. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990887 · Cited by 813
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci.
Kurosawa, H., Fukubayashi, T., & Nakajima, H. (1980) · PubMed · Cited by 528
Articular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Butler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513 · cited 1×
“D nonlinear relationship was employed: where el is the nonlinear strain level parameter assumed to be 0.03 as in previous studies (Butler et al., 1986; Li et al., 1999; Pandy et al., 1997).”
InfluentialA Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1470171 · Cited by 493 · cited 6×
“This digitizing system attempts to minimize the effects of dehydration of the exposed tissue (Haut et al., 1997).”
InfluentialSelf-citationLoad-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
KUROSAWA, H., FUKUBAYASHI, T., & NAKAJIMA, H. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00039 · Cited by 469
Cited by
Muscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Validation of computational models in biomechanics
Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim649 · Cited by 204
Orsi, A. D., Canavan, P. K., Vaziri, A., Goebel, R., Kapasi, O. A., & Nayeb-Hashemi, H. (2017) · The Knee · doi:10.1016/j.knee.2017.02.010 · Cited by 41
Orsi, A. D., Chakravarthy, S., Canavan, P. K., Peña, E., Goebel, R., Vaziri, A., & Nayeb-Hashemi, H. (2016) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2015.1043626 · Cited by 24
“Bone was modeled as rigid, as it is much stiffer than the soft tissue it interacts with (Fung and Zhang 2003; Haut Donahue et al. 2003; Yang et al. 2010a; Homyk et al. 2012).”
Influential
Metadata
- Authors
- Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 36
- Issue
- 1
- Pages
- 19-34
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2103051705
- Cited by
- 247
- References
- 38
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. https://app.cochat.ai/papers/10.1016/s0021-9290(02)00305-6
- The paper
- Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2003). How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(02)00305-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.