Physicochemical Characterization and Drug Release of Thermosensitive Hydrogels Composed of a Hyaluronic Acid/Pluronic F127 Graft
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pluronic F127 (PF127) is a copolymer which forms thermosensitive hydrogels. Hyaluronic acid (HA) was grafted to PF127 to form a new hydrogel matrix (HP) for delivery of cisplatin and carboplatin. The physicochemical properties and drug delivery of the graft were examined in this study. HP system (20% HP copolymer in water) exhibited a similar sol-gel transition temperature (28.3 degrees C) as PF127 system (20% PF127 copolymer in water) but with a shorter gelling process. A stronger structure was obtained by HP system according to scanning electron microscopic (SEM) images and viscosity kinetics. In vitro release test showed the sustained-release characteristics of hydrogels entrapped with cisplatin and carboplatin. The drug release rate from HP hydrogel was slower than that from PF127 hydrogel. The reduction of drug release by HP system as compared to the control solution was more significant for cisplatin than for carboplatin. Such a thermosensitive hydrogel may be advantageous as an injectable therapeutic formulation for anticancer treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
Cited by
Recent progress in biomedical applications of pluronic (PF127): Pharmaceutical perspectives
Akash, M. S. H., & Rehman, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.04.032 · Cited by 394
Injectable hydrogels for delivering biotherapeutic molecules
Mathew, A. P., Uthaman, S., Cho, K.-H., Cho, C.-S., & Park, I.-K. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.11.113 · Cited by 262
Review of Stimuli-Responsive Polymers in Drug Delivery and Textile Application
CHATTERJEE, S., & Chi-leung HUI, P. (2019) · Molecules · doi:10.3390/molecules24142547 · Cited by 201
“The thermo-responsive hydrogel made of hyaluronic acid grafted PF127 showed in situ gel formation and was applied for delivery of model anti-cancer drugs cisplatin and carboplatin [97].”
MethodChatterjee, S., Hui, P. C.-L., & Kan, C.-W. (2018) · Polymers · doi:10.3390/polym10050480 · Cited by 196
“The drug release rate from HP hydrogel was slower than that from PF127 hydrogel and such thermosensitive hydrogel system was expected to be advantageous as an injectable therapeutic formulation for anticancer treatment [188].”
BackgroundChen, Y.-Y., Wu, H.-C., Sun, J.-S., Dong, G.-C., & Wang, T.-W. (2013) · Langmuir · doi:10.1021/la400268p · Cited by 126
Metadata
- Authors
- Hsu, S.-H., Leu, Y.-L., Hu, J.-W., & Fang, J.-Y.
- Venue
- Chemical and Pharmaceutical Bulletin
- Publisher
- Pharmaceutical Society of Japan
- Published
- 2009
- Volume
- 57
- Issue
- 5
- Pages
- 453-458
- ISSN
- 0009-2363 (ISSN-L)
- 1347-5223
- OpenAlex
- W2055036254
- Cited by
- 68
- References
- 1
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.