Regulation of central blood volume and cardiac filling in endurance athletes: the Frank-Starling mechanism as a determinant of orthostatic tolerance
The DOI matches its Crossref record.
Abstract
LEVINE, B. D. Regulation of central blood volume and cardiac filling in endurance athletes: the Frank-Starling mechanism as a determinant of orthostatic tolerance. Med. Sci. Sports Exerc., Vol. 25, No. 6, pp. 727–732, 1993. Orthostatic intolerance may result from either an abnormally large postural decrease in central blood volume, cardiac filling pressures, and stroke volume, or inadequate neurohumoral responses to orthostasis. Endurance athletes have been reported as having a high incidence of orthostatic intolerance, which has been attributed primarily to abnormalities in baroref ex regulation of heart rate and peripheral resistance. In this review, we present evidence that athletes also have structural changes in the cardiovascular system that although beneficial during exercise, lead to an excessively large decrease in stroke volume during orthostasis and contribute to orthostatic intolerance. A unifying hypothesis based on cardiac mechanics that may explain the divergence of findings in conditions such as bed rest or spaceflight, and short- and long-term endurance training is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, P., Andriesse, G. I., Oey, P. L., Wieneke, G. H., Roelofs, J. M. M., & Akkermans, L. M. A. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00276-7 · Cited by 767
Orthostatic intolerance after spaceflight
Buckey, J. C., Lane, L. D., Levine, B. D., Watenpaugh, D. E., Wright, S. J., Moore, W. E., Gaffney, F. A., & Blomqvist, C. G. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.1.7 · Cited by 596
Self-citationCardiac Atrophy After Bed-Rest Deconditioning: A Nonneural Mechanism for Orthostatic Intolerance
Levine, B. D., Zuckerman, J. H., & Pawelczyk, J. A. (1997) · Circulation · doi:10.1161/01.cir.96.2.517 · Cited by 371
Self-citationCardiac origins of the postural orthostatic tachycardia syndrome
Fu, Q., VanGundy, T. B., Galbreath, M. M., Shibata, S., Jain, M., Hastings, J. L., Bhella, P. S., & Levine, B. D. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.043 · Cited by 329
Self-citationGender differences in autonomic functions associated with blood pressure regulation
Convertino, V. A. (1998) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1998.275.6.r1909 · Cited by 328
Hemodynamics of orthostatic intolerance: implications for gender differences
Fu, Q., Arbab-Zadeh, A., Perhonen, M. A., Zhang, R., Zuckerman, J. H., & Levine, B. D. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00735.2002 · Cited by 219
“The relationship between SV and LV end-diastolic pressure, namely, the Frank-Starling mechanism, is a key determinant governing the magnitude of the decrease in SV during orthostatic stress in humans (27, 29, 41).”
BackgroundSelf-citationLower Body Negative Pressure: Physiological Effects, Applications, and Implementation
Goswami, N., Blaber, A. P., Hinghofer-Szalkay, H., & Convertino, V. A. (2019) · Physiological Reviews · doi:10.1152/physrev.00006.2018 · Cited by 217
Effects of gender and hypovolemia on sympathetic neural responses to orthostatic stress
Fu, Q., Witkowski, S., Okazaki, K., & Levine, B. D. (2005) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00013.2005 · Cited by 187
“Individuals with reduced vascular volumes exhibit subnormal cardiac filling pressure, and the capacity to buffer orthostatic reductions in central blood volume is limited (11, 20, 22, 32).”
BackgroundSelf-citationExercise and the autonomic nervous system
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53491-0.00013-4 · Cited by 185
ECTOR, H., REYBROUCK, T., HEIDBÜCHEL, H., GEWILLIG, M., & VAN DE WERF, F. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01087.x · Cited by 167
Effect of alterations in blood volume on cardiac function during maximal exercise
KRIP, B., GLEDHILL, N., JAMNIK, V., & WARBURTON, D. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199711000-00013 · Cited by 160
Carrick-Ranson, G., Howden, E. J., Brazile, T. L., Levine, B. D., & Reading, S. A. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00798.2022 · Cited by 23
Self-citationEDITORIAL: Why do young women (donors) faint?
Fu, Q., & Levine, B. D. (2010) · Transfusion · doi:10.1111/j.1537-2995.2010.02593.x · Cited by 10
Self-citation
Metadata
- Authors
- LEVINE, B. D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1993-06
- Volume
- 25
- Issue
- 6
- Pages
- 727???732
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1977418225
- Cited by
- 93
- References
- 0
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.