Predicting Energy Expenditure from Accelerometry Counts in Adolescent Girls
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: Calibration of accelerometer counts against oxygen consumption to predict energy expenditure has not been conducted in middle school girls. We concurrently assessed energy expenditure and accelerometer counts during physical activities on adolescent girls to develop an equation to predict energy expenditure. METHODS: Seventy-four girls aged 13-14 yr performed 10 activities while wearing an Actigraph accelerometer and a portable metabolic measurement unit (Cosmed K4b2). The activities were resting, watching television, playing a computer game, sweeping, walking 2.5 and 3.5 mph, performing step aerobics, shooting a basketball, climbing stairs, and running 5 mph. Height and weight were also assessed. Mixed-model regression was used to develop an equation to predict energy expenditure (EE) (kJ.min(-1)) from accelerometer counts. RESULTS: Age (mean [SD] = 14 yr [0.34]) and body-weight-adjusted correlations of accelerometer counts with EE (kJ.min(-1)) for individual activities ranged from -0.14 to 0.59. Higher intensity activities with vertical motion were best correlated. A regression model that explained 85% of the variance of EE was developed: [EE (kJ.min(-1)) = 7.6628 + 0.1462 [(Actigraph counts per minute - 3000)/100] + 0.2371 (body weight in kilograms) - 0.00216 [(Actigraph counts per minute - 3000)/100](2) + 0.004077 [((Actigraph counts per minute - 3000)/100) x (body weight in kilograms)]. The MCCC = 0.85, with a standard error of estimate = 5.61 kJ.min(-1). CONCLUSIONS: We developed a prediction equation for kilojoules per minute of energy expenditure from Actigraph accelerometer counts. This equation may be most useful for predicting energy expenditure in groups of adolescent girls over a period of time that will include activities of broad-ranging intensity, and may be useful to intervention researchers interested in objective measures of physical activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“There have been studies that have calibrated accelerometer counts against oxygen consumption in adults (4) and children (14), but not in middle school aged children, nor toward the goal of predicting daily energy expenditure in middle school aged children.”
BackgroundMaximum Likelihood Approaches to Variance Component Estimation and to Related Problems
Harville, D. A. (1977) · Journal of the American Statistical Association · doi:10.1080/01621459.1977.10480998 · Cited by 2,667 · cited 1×
“Prediction of energy expenditure in kilojoules per minute from accelerometer counts was accomplished with a regression analysis based on the general linear mixed model (5).”
MethodValidity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643 · cited 2×
“(3) reported R2 values for the equation to predict oxygen uptake from accelerometer counts of 0.”
BackgroundCalorimetric Validation of the Caltrac® Accelerometer during Level Walking
Balogun, J. A., Martin, D. A., & Clendenin, M. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.6.501 · Cited by 57
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Calibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Validation and Calibration of an Accelerometer in Preschool Children
Pate, R. R., Almeida, M. J., McIver, K. L., Pfeiffer, K. A., & Dowda, M. (2006) · Obesity · doi:10.1038/oby.2006.234 · Cited by 723
Self-citationMetcalf, B., Henley, W., & Wilkin, T. (2012) · BMJ · doi:10.1136/bmj.e5888 · Cited by 658
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Metadata
- Authors
- SCHMITZ, K. H., TREUTH, M., HANNAN, P., MCMURRAY, R., RING, K. B., CATELLIER, D., & PATE, R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-01
- Volume
- 37
- Issue
- 1
- Pages
- 155-161
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2126813106
- Cited by
- 114
- References
- 5
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.