Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record.

Validation and Calibration of the Actical Accelerometer in Preschool Children

PFEIFFER, KARIN A., MCIVER, KERRY L., DOWDA, MARSHA, ALMEIDA, MARIA J.C.A., PATE, RUSSELL R.·2006·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: Decreased physical activity (PA) is likely a contributor to the rising prevalence of obesity in children. Lack of valid and acceptable measures of PA has been an issue in studies involving young children. The Actical accelerometer is a promising tool for measurement of PA in young children. The purpose of this study was to calibrate and validate the Actical accelerometer for use with 3- to 5-yr-old children. METHODS: Eighteen preschool children wore an Actical accelerometer and a Cosmed portable metabolic system during a period of rest, while performing three structured activities in a laboratory setting (used for calibration), and during 20 min each of unstructured indoor and outdoor activities at their preschool (used for cross-validation). Expired respiratory gases were collected, and oxygen consumption was measured on a breath-by-breath basis. Accelerometer data were collected in 15-s intervals. RESULTS: For the accelerometer calibration, the correlation between VO2 and counts was r = 0.89 across all activities. The calibration equation established was VO2 = counts x 15 s(-1) (0.01437) + 9.73 (R2 = 0.96, SEE = 3.02). The cut-point for moderate activity (20 mL x kg(-1) x min(-1)) was 715 counts x 15 s(-1) (sensitivity 97.2%, specificity 91.7%), and the cut-point for vigorous activity (30 mL x kg(-1) x min(-1)) was 1411 counts x 15 s(-1) (sensitivity 98.2%, specificity 61.1%). For the cross-validation, the intraclass correlation coefficient was R = 0.59 and the Spearman correlation coefficient was R = 0.80 (P < 0.001) between measured and predicted VO2. Percentage of agreement, kappa, and modified kappa for moderate activity were 0.73, 0.40, and 0.46, respectively. For vigorous activity, the same measures were 0.85, 0.26, and 0.71, respectively. CONCLUSION: The Actical accelerometer is a valid tool for measuring PA in young children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000183219.44127.e7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
PFEIFFER, K. A., MCIVER, K. L., DOWDA, M., ALMEIDA, M. J. C. A., & PATE, R. R.
Venue
Medicine & Science in Sports & Exercise
Published
2006-01
Volume
38
Issue
1
Pages
152-157
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2011334287
Cited by
232
References
0
FWCI
3.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation and Calibration of the Actical Accelerometer in Preschool Children. https://app.cochat.ai/papers/10.1249/01.mss.0000183219.44127.e7
The paper
PFEIFFER, K. A., MCIVER, K. L., DOWDA, M., ALMEIDA, M. J. C. A., & PATE, R. R. (2006). Validation and Calibration of the Actical Accelerometer in Preschool Children. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000183219.44127.e7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.