The DOI matches its Crossref record.
Validation and Calibration of the Actical Accelerometer in Preschool Children
Abstract
PURPOSE: Decreased physical activity (PA) is likely a contributor to the rising prevalence of obesity in children. Lack of valid and acceptable measures of PA has been an issue in studies involving young children. The Actical accelerometer is a promising tool for measurement of PA in young children. The purpose of this study was to calibrate and validate the Actical accelerometer for use with 3- to 5-yr-old children. METHODS: Eighteen preschool children wore an Actical accelerometer and a Cosmed portable metabolic system during a period of rest, while performing three structured activities in a laboratory setting (used for calibration), and during 20 min each of unstructured indoor and outdoor activities at their preschool (used for cross-validation). Expired respiratory gases were collected, and oxygen consumption was measured on a breath-by-breath basis. Accelerometer data were collected in 15-s intervals. RESULTS: For the accelerometer calibration, the correlation between VO2 and counts was r = 0.89 across all activities. The calibration equation established was VO2 = counts x 15 s(-1) (0.01437) + 9.73 (R2 = 0.96, SEE = 3.02). The cut-point for moderate activity (20 mL x kg(-1) x min(-1)) was 715 counts x 15 s(-1) (sensitivity 97.2%, specificity 91.7%), and the cut-point for vigorous activity (30 mL x kg(-1) x min(-1)) was 1411 counts x 15 s(-1) (sensitivity 98.2%, specificity 61.1%). For the cross-validation, the intraclass correlation coefficient was R = 0.59 and the Spearman correlation coefficient was R = 0.80 (P < 0.001) between measured and predicted VO2. Percentage of agreement, kappa, and modified kappa for moderate activity were 0.73, 0.40, and 0.46, respectively. For vigorous activity, the same measures were 0.85, 0.26, and 0.71, respectively. CONCLUSION: The Actical accelerometer is a valid tool for measuring PA in young children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Prediction of Energy Expenditure and Physical Activity in Preschoolers
BUTTE, N. F., WONG, W. W., LEE, J. S., ADOLPH, A. L., PUYAU, M. R., & ZAKERI, I. F. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000209 · Cited by 273
Longitudinal analysis of sleep in relation to BMI and body fat in children: the FLAME study
Carter, P. J., Taylor, B. J., Williams, S. M., & Taylor, R. W. (2011) · BMJ · doi:10.1136/bmj.d2712 · Cited by 226
Validity and Reproducibility of Motion Sensors in Youth: A Systematic Update
DE VRIES, S. I., VAN HIRTUM, H. W. J. E. M., BAKKER, I., HOPMAN-ROCK, M., HIRASING, R. A., & VAN MECHELEN, W. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818e5819 · Cited by 201
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
Metadata
- Authors
- PFEIFFER, K. A., MCIVER, K. L., DOWDA, M., ALMEIDA, M. J. C. A., & PATE, R. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2006-01
- Volume
- 38
- Issue
- 1
- Pages
- 152-157
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2011334287
- Cited by
- 232
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation and Calibration of the Actical Accelerometer in Preschool Children. https://app.cochat.ai/papers/10.1249/01.mss.0000183219.44127.e7
- The paper
- PFEIFFER, K. A., MCIVER, K. L., DOWDA, M., ALMEIDA, M. J. C. A., & PATE, R. R. (2006). Validation and Calibration of the Actical Accelerometer in Preschool Children. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000183219.44127.e7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.