CoChat

Oxygen Uptake and Muscle Desaturation Kinetics during Intermittent Cycling

TURNER, ANTHONY P., CATHCART, ANDREW J., PARKER, MATTHEW E., BUTTERWORTH, CHRIS, WILSON, JOHN, WARD, SUSAN A. · 2006 · Medicine & Science in Sports & Exercise
Cited by 53

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate the kinetics of O2 uptake (VO2) and m. vastus lateralis [deoxyhemoglobin] ([Hb]) (near-infrared spectroscopy) for supramaximal intermittent cycling. METHODS: Six males performed a ramp test for determination of VO2peak and lactate threshold. On different days, they completed four intermittent "work:recovery" tests (10 s:20 s, 30 s:60 s, 60 s:120 s, 90 s:180 s) for 30 min or to the tolerable limit; "work" = 120% peak work rate (WRpeak) attained on the ramp, "recovery" = 20 W. RESULTS: Arterialized capillary [lactate] ([L]c) profiles were dependent on duty-cycle length and resembled those for constant-load exercise classically used to assign exercise intensity: 10 s:20 s-no increase (i.e., "moderate", with first-order VO2 kinetics); 30 s:60 s-increased but stable (i.e., "heavy," with first-order VO2 kinetics supplemented by a slow component (VO2 sc) that stabilizes); 60s:120s-progressive increase that was more marked for 90 s:180 s (i.e., "very heavy" or "severe," with first-order VO2 kinetics supplemented by a VO2 sc projecting to VO2peak). VO2 and Delta[Hb] oscillated with WR, the ensemble-averaged single-cycle oscillation amplitudes (peak-to-nadir) for each individual subject increasing with WR duty-cycle duration. In the 30-s:60-s test, with [L]c being elevated, there was also a tendency towards a modest VO2 sc, with an increase in individual VO2 peak values early in the test and VO2 not fully recovering back to baseline in recovery. This was more marked for the 60-s:120-s duty cycle: VO2 failed to recover completely back to baseline, and the peaks of the VO2 oscillations increased significantly with time (F = 30.7, P < 0.001); in some cases, VO2peak was attained and exhaustion rapidly ensued. CONCLUSION: VO2 kinetics in intermittent exercise over a range of duty-cycle durations tended to associate with blood [lactate] profiles, similarly to previous demonstrations for sustained constant-load exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000188450.82733.f0

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
TURNER, A. P., CATHCART, A. J., PARKER, M. E., BUTTERWORTH, C., WILSON, J., & WARD, S. A.
Venue
Medicine & Science in Sports & Exercise
Published
2006-03
Volume
38
Issue
3
Pages
492-503
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2094560783
Cited by
53
References
5
FWCI
6.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.