A 3-min All-Out Test to Determine Peak Oxygen Uptake and the Maximal Steady State
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
PURPOSE: We tested the hypothesis that a 3-min all-out cycling test would provide a measure of peak oxygen uptake (VO2peak) and estimate the maximal steady-state power output. METHODS: Eleven habitually active subjects performed a ramp test, three 3-min all-out tests against a fixed resistance, and two further submaximal tests lasting up to 30 min, 15 W below or above the power output attained in the last 30 s of the 3-min test (the end-test power). RESULTS: The VO2peak measured during the 3-min all-out test (mean +/- SD: 3.78 +/- 0.68 L x min(-1)) was not different from that of the ramp test (3.84 +/- 0.79 L x min(-1); P = 0.75). The end-test power (257 +/- 49 W) was significantly lower than that at the end of the ramp test (368 +/- 73 W) and significantly higher than the power at the gas exchange threshold (169 +/- 55 W; P < 0.001). Nine subjects were able to complete 30 min of exercise at 15 W below the end-test power, and seven of these did so with a steady-state blood [lactate] and VO2 response profile. In contrast, when subjects exercised at 15 W above the end-test power, blood [lactate] and VO2 rose inexorably until exhaustion, which occurred in approximately 13 +/- 7 min. CONCLUSIONS: These data suggest that a 3-min all-out exercise test can be used to establish VO2peak and to estimate the maximal steady state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
THE WORK CAPACITY OF A SYNERGIC MUSCULAR GROUP
MONOD, H., & SCHERRER, J. (1965) · Ergonomics · doi:10.1080/00140136508930810 · Cited by 872
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
POOLE, D. C., WARD, S. A., GARDNER, G. W., & WHIPP, B. J. (1988) · Ergonomics · doi:10.1080/00140138808966766 · Cited by 779
The Slow Component of Oxygen Uptake Kinetics in Humans
GAESSER, G. A., & POOLE, D. C. (1996) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199600240-00004 · Cited by 663
Anaerobic capacity determined by maximal accumulated O2 deficit
Medbo, J. I., Mohn, A. C., Tabata, I., Bahr, R., Vaage, O., & Sejersted, O. M. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.1.50 · Cited by 661
A test to determine parameters of aerobic function during exercise
Whipp, B. J., Davis, J. A., Torres, F., & Wasserman, K. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.1.217 · Cited by 657
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
On-line computer analysis and breath-by-breath graphical display of exercise function tests.
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.1.128 · Cited by 318
The slow component of O2 uptake kinetics during heavy exercise
WHIPP, B. J. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199411000-00005 · Cited by 285
Determination of maximal lactate steady state response in selected sports events
BENEKE, R., & von DUVILLARD, S. P. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199602000-00013 · Cited by 247
Poole, D. C., Ward, S. A., & Whipp, B. J. (1990) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf02388623 · Cited by 236
Maximal lactate steady state, critical power and EMG during cycling
Pringle, J., & Jones, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0703-4 · Cited by 224
The relationship between power and the time to achieve &OV0312;O2max
HILL, D. W., POOLE, D. C., & SMITH, J. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200204000-00023 · Cited by 220
Smith, C. G. M., & Jones, A. M. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100384 · Cited by 186
The validity of the lactate minimum test for determination of the maximal lactate steady state
JONES, A. M., & DOUST, J. H. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199808000-00020 · Cited by 186
Self-citationPhysiological responses during exercise to exhaustion at critical power
Brickley, G., Doust, J. H., & Williams, C. A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0706-1 · Cited by 122
Self-citationA metabolic limit on the ability to make up for lost time in endurance events
Fukuba, Y., & Whipp, B. J. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.853 · Cited by 119
Accumulated oxygen deficit during supramaximal all-out and constant intensity exercise
GASTIN, P. B., COSTILL, D. L., LAWSON, D. L., KRZEMINSKI, K., & McCONELL, G. K. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199502000-00016 · Cited by 112
The Curvature Constant Parameter of the Power-Duration Curve for Varied-Power Exercise
Fukuba, Y., Miura, A., Endo, M. Y., Kan, A., Yanagawa, K., & Whipp, B. J. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079047.84364.70 · Cited by 103
Intensity-dependent tolerance to exercise after attaining V o 2 max in humans
Coats, E. M., Rossiter, H. B., Day, J. R., Miura, A., Fukuba, Y., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01142.2002 · Cited by 93
Oxygen deficits incurred during 45, 60, 75 and 90-s maximal cycling on an air-braked ergometer
Withers, R. T., van der Ploeg, G. E., & Finn, J. P. (1993) · European Journal of Applied Physiology · doi:10.1007/bf00376665 · Cited by 79
Validity of the two-parameter model in estimating the anaerobic work capacity
Dekerle, J., Brickley, G., Hammond, A. J. P., PRINGLE, J. S. M., & Carter, H. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0074-8 · Cited by 53
Gastin, P. B., & Lawson, D. L. (1994) · European Journal of Applied Physiology · doi:10.1007/bf00392039 · Cited by 49
Validity of a Single-Visit Protocol to Estimate the Maximum Lactate Steady State
KILDING, A. E., & JONES, A. M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181691.72432.a1 · Cited by 38
Cited by
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Self-citationAn Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Determination of Critical Power Using a 3-min All-out Cycling Test
VANHATALO, A., DOUST, J. H., & BURNLEY, M. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802dd3e6 · Cited by 356
Self-citationThe maximal metabolic steady state: redefining the ‘gold standard’
Jones, A. M., Burnley, M., Black, M. I., Poole, D. C., & Vanhatalo, A. (2019) · Physiological Reports · doi:10.14814/phy2.14098 · Cited by 298
Self-citationSignificant Molecular and Systemic Adaptations after Repeated Sprint Training in Hypoxia
Faiss, R., Léger, B., Vesin, J.-M., Fournier, P.-E., Eggel, Y., Dériaz, O., & Millet, G. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056522 · Cited by 294
Metadata
- Authors
- BURNLEY, M., DOUST, J. H., & VANHATALO, A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2006-11
- Volume
- 38
- Issue
- 11
- Pages
- 1995-2003
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2056105157
- Cited by
- 258
- References
- 24
- FWCI
- 10.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.