The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Comparing the performance of three generations of ActiGraph accelerometers
Open accessAbstract
ActiGraph accelerometers are a useful tool for objective assessment of physical activity in clinical and epidemiological studies. Several generations of ActiGraph are being used; however, little work has been done to verify that measurements are consistent across generations. This study employed mechanical oscillations to characterize the dynamic response and intermonitor variability of three generations of ActiGraph monitors, from the oldest 7164 ( n = 13), 71256 ( n = 12), to the newest GT1M ( n = 12). The response due to independent radius (22.1–60.4 mm) and frequency (25–250 rpm) changes were measured, as well as intermonitor variability within each generation. The 7164 and 71256 have similar relationships between activity counts and radius ( P = 0.229) but were significantly different from the GT1M ( P < 0.001). The frequency responses were nonlinear in all three generations. Although the response curve shapes were similar, the differences between generations at various frequencies were significant ( P < 0.017), especially in the extremes of the measurement range. Intermonitor variability was markedly reduced in the GT1M compared with the 7164 and 71256. Other measurement differences between generations include decreased peak counts and decreased sensitivity in low-frequency detection in the GT1M. The results of this study revealed an improvement of the intermonitor variability by the GT1M monitor. However, the reduced sensitivity in low-count ranges in the GT1M may not be well suited for monitoring sedentary or light-intensity movements. Furthermore, the algorithms for energy expenditure predictions developed using older 7164 monitors may need to be modified for the GT1M.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631
Self-citationObjectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Healy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2007) · Diabetes Care · doi:10.2337/dc07-0114 · Cited by 627
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Validation of Wearable Monitors for Assessing Sedentary Behavior
KOZEY-KEADLE, S., LIBERTINE, A., LYDEN, K., STAUDENMAYER, J., & FREEDSON, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820ce174 · Cited by 905
Using Accelerometers in Youth Physical Activity Studies: A Review of Methods
Cain, K. L., Sallis, J. F., Conway, T. L., Van Dyck, D., & Calhoon, L. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.3.437 · Cited by 713
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
A step-defined sedentary lifestyle index: <5000 steps/day
Tudor-Locke, C., Craig, C. L., Thyfault, J. P., & Spence, J. C. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0235 · Cited by 384
Metadata
- Authors
- Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2008-10
- Volume
- 105
- Issue
- 4
- Pages
- 1091-1097
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2113128100
- Cited by
- 177
- References
- 6
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing the performance of three generations of ActiGraph accelerometers. https://app.cochat.ai/papers/10.1152/japplphysiol.90641.2008
- The paper
- Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008). Comparing the performance of three generations of ActiGraph accelerometers. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.90641.2008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.