Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study aimed to establish physical activity (PA) intensity cutpoints for a wrist-mounted GENEActiv accelerometer (ACC) in elementary school-age children. A second purpose was to apply cutpoints to a free-living sample and examine the duration of PA based on continuous 1-s epochs. METHODS: Metabolic and ACC data were collected during nine typical activities in 24 children age 6-11 yr. Measured VO2 values were divided by Schofield-estimated resting values to determine METs. ACC data were collected at 75 Hz, band pass filtered, and averaged over each 1-s interval. Receiver operator characteristic curves were used to establish cutpoints at sedentary (≤ 1.5 METs), light (1.6-2.99 METs), moderate (3.0-5.99 METs), and vigorous (≥ 6 METs) activities. These cutpoints were applied to a free-living independent data set to quantify the amount of moderate-vigorous PA (MVPA) and to examine how bout length (1, 2, 3, 5, 10, 15, and 60 s) affected the accumulation of MVPA. RESULTS: Receiver operator characteristic yielded areas under the curve of 0.956, 0.946, and 0.940 for sedentary, moderate, and vigorous intensities, respectively. Cutpoints for sedentary, moderate, and vigorous intensities were 0.190 g, 0.314 g, and 0.998 g, respectively. Intensity classification accuracies ranged from 27.6% (light) to 88.7% (vigorous) when cutpoints were applied to the calibration data. When applied to free-living data (n = 47 children age 6-11 yr), estimated daily MVPA was 308 min and decreased to 14.3 min when only including 1-min periods of continuous MVPA. CONCLUSIONS: Cutpoints that quantify movements associated with moderate-vigorous intensity, when applied to a laboratory protocol, result in large amounts of accumulated MVPA using the 1-s epoch compared to prior studies, highlighting the need for representative calibration activities and free-living validation of cutpoints and epoch length selection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Patterns of habitual activity across weekdays and weekend days in 9–11-year-old children
Rowlands, A. V., Pilgrim, E. L., & Eston, R. G. (2008) · Preventive Medicine · doi:10.1016/j.ypmed.2007.11.004 · Cited by 209
Rowlands, A. V., Pilgrim, E. L., & Eston, R. G. (2009) · Annals of Human Biology · doi:10.1080/03014460902824220 · Cited by 64
Cited by
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Evaluation of raw acceleration sedentary thresholds in children and adults
Hildebrand, M., Hansen, B. H., van Hees, V. T., & Ekelund, U. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12795 · Cited by 425
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Chandler, J. L., Brazendale, K., Beets, M. W., & Mealing, B. A. (2016) · Pediatric Obesity · doi:10.1111/ijpo.12033 · Cited by 275
García‐Hermoso, A., Hormazábal‐Aguayo, I., Fernández‐Vergara, O., González‐Calderón, N., Russell‐Guzmán, J., Vicencio‐Rojas, F., Chacana‐Cañas, C., & Ramírez‐Vélez, R. (2020) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13537 · Cited by 62
Metadata
- Authors
- SCHAEFER, C. A., NIGG, C. R., HILL, J. O., BRINK, L. A., & BROWNING, R. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2014-04
- Volume
- 46
- Issue
- 4
- Pages
- 826-833
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1980446982
- Cited by
- 80
- References
- 8
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth. https://app.cochat.ai/papers/10.1249/mss.0000000000000150
- The paper
- SCHAEFER, C. A., NIGG, C. R., HILL, J. O., BRINK, L. A., & BROWNING, R. C. (2014). Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.