CoChat

Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth

Open access
SCHAEFER, CHRISTINE A., NIGG, CLAUDIO R., HILL, JAMES O., BRINK, LOIS A., BROWNING, RAYMOND C. · 2014 · Medicine & Science in Sports & Exercise
Cited by 80

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: This study aimed to establish physical activity (PA) intensity cutpoints for a wrist-mounted GENEActiv accelerometer (ACC) in elementary school-age children. A second purpose was to apply cutpoints to a free-living sample and examine the duration of PA based on continuous 1-s epochs. METHODS: Metabolic and ACC data were collected during nine typical activities in 24 children age 6-11 yr. Measured VO2 values were divided by Schofield-estimated resting values to determine METs. ACC data were collected at 75 Hz, band pass filtered, and averaged over each 1-s interval. Receiver operator characteristic curves were used to establish cutpoints at sedentary (≤ 1.5 METs), light (1.6-2.99 METs), moderate (3.0-5.99 METs), and vigorous (≥ 6 METs) activities. These cutpoints were applied to a free-living independent data set to quantify the amount of moderate-vigorous PA (MVPA) and to examine how bout length (1, 2, 3, 5, 10, 15, and 60 s) affected the accumulation of MVPA. RESULTS: Receiver operator characteristic yielded areas under the curve of 0.956, 0.946, and 0.940 for sedentary, moderate, and vigorous intensities, respectively. Cutpoints for sedentary, moderate, and vigorous intensities were 0.190 g, 0.314 g, and 0.998 g, respectively. Intensity classification accuracies ranged from 27.6% (light) to 88.7% (vigorous) when cutpoints were applied to the calibration data. When applied to free-living data (n = 47 children age 6-11 yr), estimated daily MVPA was 308 min and decreased to 14.3 min when only including 1-min periods of continuous MVPA. CONCLUSIONS: Cutpoints that quantify movements associated with moderate-vigorous intensity, when applied to a laboratory protocol, result in large amounts of accumulated MVPA using the 1-s epoch compared to prior studies, highlighting the need for representative calibration activities and free-living validation of cutpoints and epoch length selection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000000150

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 80

Metadata

Authors
SCHAEFER, C. A., NIGG, C. R., HILL, J. O., BRINK, L. A., & BROWNING, R. C.
Venue
Medicine & Science in Sports & Exercise
Published
2014-04
Volume
46
Issue
4
Pages
826-833
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1980446982
Cited by
80
References
8
FWCI
2.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth. https://app.cochat.ai/papers/10.1249/mss.0000000000000150
The paper
SCHAEFER, C. A., NIGG, C. R., HILL, J. O., BRINK, L. A., & BROWNING, R. C. (2014). Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.