The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Validity of Consumer-Based Physical Activity Monitors
Abstract
BACKGROUND: Many consumer-based monitors are marketed to provide personal information on the levels of physical activity and daily energy expenditure (EE), but little or no information is available to substantiate their validity. PURPOSE: This study aimed to examine the validity of EE estimates from a variety of consumer-based, physical activity monitors under free-living conditions. METHODS: Sixty (26.4 ± 5.7 yr) healthy males (n = 30) and females (n = 30) wore eight different types of activity monitors simultaneously while completing a 69-min protocol. The monitors included the BodyMedia FIT armband worn on the left arm, the DirectLife monitor around the neck, the Fitbit One, the Fitbit Zip, and the ActiGraph worn on the belt, as well as the Jawbone Up and Basis B1 Band monitor on the wrist. The validity of the EE estimates from each monitor was evaluated relative to criterion values concurrently obtained from a portable metabolic system (i.e., Oxycon Mobile). Differences from criterion measures were expressed as a mean absolute percent error and were evaluated using 95% equivalence testing. RESULTS: For overall group comparisons, the mean absolute percent error values (computed as the average absolute value of the group-level errors) were 9.3%, 10.1%, 10.4%, 12.2%, 12.6%, 12.8%, 13.0%, and 23.5% for the BodyMedia FIT, Fitbit Zip, Fitbit One, Jawbone Up, ActiGraph, DirectLife, NikeFuel Band, and Basis B1 Band, respectively. The results from the equivalence testing showed that the estimates from the BodyMedia FIT, Fitbit Zip, and NikeFuel Band (90% confidence interval = 341.1-359.4) were each within the 10% equivalence zone around the indirect calorimetry estimate. CONCLUSIONS: The indicators of the agreement clearly favored the BodyMedia FIT armband, but promising preliminary findings were also observed with the Fitbit Zip.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, given the pace of technological change, these existing studies have largely been completed on devices that would be considered outdated, such as earlier Fitbit models (One, Zip, Flex, Ultra), Jawbone Up, and the Nike FuelBand.”
From Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices (2017) · cites this paper as [10]
In the citing paper
“Most research has primarily focused on the accuracy of estimates of EE [7-12].”
From Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices (2017) · cites this paper as [10]
In the citing paper
“One previous study [10] found MAPE for Fitbit Zip (10.1%) and Fitbit One (10.4%) to be much lower than the results from this study, where MAPE was between 16.85% and 84.98%.”
From Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices (2017) · cites this paper as [10]
In the citing paper
“For example, while Fitbit models have changed over time, the basic error rate has been similar across studies and devices [8,10].”
From Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices (2017) · cites this paper as [10]
Citations
Cites
Compher, C., Frankenfield, D., Keim, N., & Roth-Yousey, L. (2006) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.02.009 · Cited by 923 · cited 1×
“after a 10-h fast, following previously published guidelines (6).”
MethodValidity of four motion sensors in measuring moderate intensity physical activity
Bassett, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 533
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
Johannsen, D. L., Calabro, M. A., Stewart, J. W., Franke, W. D., Rood, J. C., & Welk, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 433
Self-citationReliability of accelerometry-based activity monitors: a generalizability study.
Welk, G. J., Schaben, J. A., & Morrow, J. R. (2004) · PubMed · Cited by 394
Self-citationStaudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Validity and Reliability issues in Objective Monitoring of Physical Activity
Bassett, D. R. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082783 · Cited by 330
Testing Statistical Hypotheses of Equivalence
Wellek, S. (2002) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420035964 · Cited by 323
Predictive Validity of Three ActiGraph Energy Expenditure Equations for Children
Trost, S. G., Way, R., & Okely, A. D. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000183848.25845.e0 · Cited by 220
A new statistical procedure for testing equivalence in two-group comparative bioavailability trials
Hauck, W. W., & Anderson, S. (1984) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01063612 · Cited by 209
Comparison of Four ActiGraph Accelerometers during Walking and Running
John, D., Tyo, B. M., & Bassett, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181b3af49 · Cited by 183
Cited by
Sorted by citations
Items 201–300 of 401
Kim, Y., & Lochbaum, M. R. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15102268 · Cited by 20
Self-citationKinney, A. Y., Blair, C. K., Guest, D., Ani, J., Harding, E. M., Amorim, F., Boyce, T., Rodman, J., Ford, C. G., Schwartz, M. R., et al. (2019) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2019.100431 · Cited by 21
“Participants are also asked to wear a pedometer and are trained on how to use it to record the number of steps they take each day [97].”
BackgroundValidity of the activPAL and Height-Adjusted Curvilinear Cadence-METs Equations in Healthy Adults
O'Brien, M. W., Johns, J. A., Fowles, J. R., & Kimmerly, D. S. (2020) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1724112 · Cited by 18
“Consistent with previous research of a similar nature (Bai et al., 2018; Lee et al., 2014), the equivalence zone was set at ±10% of the criterionmean value.”
Validation of wearable activity monitors for real-time cadence
Han, H., Kim, H., Sun, W., Malaska, M., & Miller, B. M. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1702281 · Cited by 17
Moller, A. C., Majewski, S., Standish, M. P., Agarwal, P., Podowski, A., Carson, R., Eyesus, B., Shah, A., & Schneider, K. L. (2014) · JMIR Serious Games · doi:10.2196/games.3691 · Cited by 17
“Lee, Kim, and Welk [23] found that the FitBit Zip achieved energy expenditure estimates within 10.1% of criterion values concurrently obtained from a portable metabolic system (ie, Oxycon Mobile).”
MethodInfluentialEvaluation on Step Counting Performance of Wristband Activity Monitors in Daily Living Environment
Wang, L., Liu, T., Wang, Y., Li, Q., Yi, J., & INOUE, Y. (2017) · IEEE Access · doi:10.1109/access.2017.2721098 · Cited by 20
Pope, Z., Zeng, N., Li, X., Liu, W., & Gao, Z. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0037 · Cited by 16
Nazari, G., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A. (2019) · Physiotherapy Canada · doi:10.3138/ptc.2018-25 · Cited by 15
Measuring the validity and reliability of the Apple Watch as a physical activity monitor
Zhang, P., Godin, S., & Owens, M. V. (2019) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.18.08339-1 · Cited by 15
Populating Aging in Rural India: Implication for Agriculture and Smallholder Farmers
Milovanovic, V., & Smutka, Ľ. (2019) · Journal of Population Ageing · doi:10.1007/s12062-019-09246-6 · Cited by 15
Gilgen-Ammann, R., Roos, L., Wyss, T., Veenstra, B., Delves, S. K., Beeler, N., Buller, M. J., & Friedl, K. E. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac19f9 · Cited by 14
Validation of Youth Oriented Activity Trackers: Comprehensive Laboratory- and Field-Based Validation
Sirard, J. R., Masteller, B. R., Freedson, P. S., Mendoza, A., & Hickey, A. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.6360 · Cited by 15
“Several studies have now evaluated validity and reliability of adult activity trackers [4-10], but there is currently no independent research validating the output from youth-oriented activity trackers.”
BackgroundAccuracy of swimming wearable watches for estimating energy expenditure
Lee, M., Lee, H., & Park, S. (2018) · IJASS(International Journal of Applied Sports Sciences) · doi:10.24985/ijass.2018.30.1.80 · Cited by 15
Active and pleasant ageing supported by technology
Cabrita, M. (2017) · doi:10.3990/1.9789036543903 · Cited by 14
Lewis, Z. H., Ottenbacher, K. J., Fisher, S. R., Jennings, K., Brown, A. F., Swartz, M. C., Martínez, E., & Lyons, E. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186800 · Cited by 15
“They provide an adequate estimation of PA [10] and they are proliferating in community-based PA interventions [8].”
BackgroundWestern, M. J., Standage, M., Peacock, O. J., Nightingale, T. E., & Thompson, D. (2021) · JMIR Formative Research · doi:10.2196/26525 · Cited by 18
“0), which has been shown to accurately measure minute-by-minute energy expenditure [37,38].”
BackgroundMea, V. D., Quattrin, O., & Parpinel, M. T. (2016) · Informatics for Health and Social Care · doi:10.1080/17538157.2016.1255214 · Cited by 13
“In addition to accelerometer data, which might eventually come from electronic activity monitors (47,48), other sensible sources of information could be the internal gyroscope of some high-end smartphones, or also the vital sign sensors being introduced in forthcoming smartwatches.”
BackgroundShook, R. P., Yeh, H., Welk, G. J., Davis, A. M., & Ries, D. (2021) · Journal of Nutrition · doi:10.1093/jn/nxab317 · Cited by 13
Self-citationDurability of benefit after transcatheter tricuspid valve intervention: insights from actigraphy
Stocker, T. J., Cohen, D. J., Arnold, S. V., Sommer, S., Braun, D., Stolz, L., Hertell, H., Weckbach, L. T., Wild, M. G., Doldi, P. M., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2467 · Cited by 14
Is Wearable Technology Part of the Future of Orthopedic Health Care?
Zarowin, J., Warnick, E., Mangan, J. J., Nicholson, K. J., Goyal, D. K. C., Galetta, M. S., Fang, T., Schroeder, G. D., Kepler, C. K., & Vaccaro, A. R. (2019) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000000776 · Cited by 14
Validity and Reliability of the Wristband Activity Monitor in Free-living Children Aged 10-17 Years.
Yang, X., Jago, R., Zhang, Q., Wang, Y. Y., Zhang, J., & Zhao, W. H. (2019) · PubMed · doi:10.3967/bes2019.103 · Cited by 14
Sun, X., Wang, Z., Fu, X., Zhao, C., Wang, F., & He, H. (2023) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2023.07.005 · Cited by 12
Tam, W., Alajlani, M., & Abd-Alrazaq, A. A. (2023) · Journal of Medical Internet Research · doi:10.2196/42950 · Cited by 13
“Furthermore, analytic data can remain unreliable, as the observed accuracy of data and errors range between 9.3% and 23.5% [53].”
InfluentialSchneider, C., Ryffel, C. P., Stuetz, L., Rabaglio, M., Suter, T. M., Campbell, K. L., Eser, P., & Wilhelm, M. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1283153 · Cited by 14
Bender, M. S., Santos, G., Villanueva, C., & Arai, S. R. (2016) · JMIR Research Protocols · doi:10.2196/resprot.5836 · Cited by 13
“Therefore, the Fitbit Zip mHealth self-monitoring lifestyle behavior tracker with an associated mHealth app was chosen, based on recommendations from previous studies [28-31].”
It's Not Just About the Product
Becker, M. Y., Matt, C., & Heß, T. (2020) · ACM SIGMIS Database the DATABASE for Advances in Information Systems · doi:10.1145/3380799.3380804 · Cited by 17
Applications of wearable technologies in healthcare: an analytical study
Thakkar, H. K., Chowdhury, S. R., Bhoi, A. K., & Barsocchi, P. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90548-0.00001-2 · Cited by 13
Automatic energy expenditure measurement for health science
Catal, C., & Akbulut, A. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.01.015 · Cited by 13
“BodyMedia which has multiple sensors was recently shown the most accurate EE estimation device in a recent review paper [16].”
MethodDerksen, J. W. G., Beijer, S., Koopman, M., Verkooijen, H. M., van de Poll-Franse, L. V., & May, A. M. (2018) · European Journal of Cancer · doi:10.1016/j.ejca.2018.06.017 · Cited by 13
Støve, M. P., Holm, R. S., Kjaersgaard, A. S., Duncker, K., Jensen, M. R., & Larsen, B. T. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1753836 · Cited by 12
“zone for HR measures between two measures [18].”
BackgroundLifelogging for Organizational Stress Measurement: Theory and Applications
Fischer, T., & Riedl, R. (2018) · SpringerBriefs in information systems · doi:10.1007/978-3-319-98711-8_1 · Cited by 12
Wallace, M., Downing, N. R., Lourens, S. G., Mills, J. A., Kim, J., Long, J. D., Paulsen, J. S., & PREDICT-HD Investigators and Coordinators of the Huntington Study Group (2016) · PLoS Currents · doi:10.1371/currents.hd.cba6ea74972cf8412a73ce52eb018c1e · Cited by 12
Older adults’ satisfaction of wearing consumer-level activity monitors
Farina, N., & Lowry, R. (2017) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668317733258 · Cited by 12
Exploratory study of a virtual community for physical activity
Elloumi, L., van Beijnum, B. V., & Hermens, H. (2018) · Health technology · doi:10.1007/s12553-018-0221-y · Cited by 10
Boddy, L., Noonan, R., Kim, Y., Rowlands, A., Welk, G. J., Knowles, Z., & Fairclough, S. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.03.015 · Cited by 15
Self-citationWearable Device Validity in Determining Step Count During Hiking and Trail Running
Navalta, J. W., Montes, J., Bodell, N. G., Aguilar, C. D., Lujan, A., Guzman, G., Kam, B. K., Manning, J. W., & DeBeliso, M. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0010 · Cited by 12
Espinoza, J., Chen, A., Orozco, J., Deavenport‐Saman, A., & Yin, L. (2017) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2017.06.004 · Cited by 12
“In one study, Fitbits were shown to have mean absolute percent error values (computed as the average absolute value of the group-level errors) of 10%, compared with a research grade portable metabolic system [41].”
Activity trackers are not valid for step count registration when walking with crutches
Ridder, R. D., & Blaiser, C. D. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.009 · Cited by 11
Seo, M.-W., Kim, Y., Jung, H. C., Kim, J., & Lee, J. M. (2020) · Sustainability · doi:10.3390/su12218803 · Cited by 11
Self-citationYamaga, Y., Svensson, T., Chung, U., & Svensson, A. K. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20054315 · Cited by 11
Recruitment and Retention of Asian Americans in Web-Based Physical Activity Promotion Programs
Chee, W., Ji, X., Kim, S., Park, S., Zhang, J., Chee, E., Tsai, H., & Im, E. (2019) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000541 · Cited by 11
WEARABLE ACTIVITY-TRACKING DEVICE FEATURE PREFERENCE AMONGST SOUTH AFRICAN GENERATION Y STUDENTS
Muller, C. (2020) · International Journal of eBusiness and eGovernment Studies · doi:10.34111/ijebeg.202012101 · Cited by 11
The use of wearables in healthcare – challenges and opportunities
Tana, J., Forss, M., & Hellstén, T. (2017) · Theseus (Ammattikorkeakoulujen) · Cited by 11
Wireless Physical Activity Monitor Use Among Adults Living With HIV: A Scoping Review
Dagenais, M., Cheng, D. K.-Y., Salbach, N. M., Brooks, D., & O’Brien, K. K. (2018) · Rehabilitation Oncology · doi:10.1097/01.reo.0000000000000153 · Cited by 9
Quantification of energy expenditure during daily living activities after stroke by multi-sensor
Compagnat, M., Daviet, J., Batcho, C. S., David, R., Salle, J., & Mandigout, S. (2019) · Brain Injury · doi:10.1080/02699052.2019.1641840 · Cited by 10
“We assumed that the maximum acceptable difference for the use of the SWA in clinical practice would be 10%, which is the usually accepted value in studies exploring the validity of such devices (30,31).”
MethodApplication of wearable devices in sports: behavior change and result effect
Yang, Q., Jian, S., Zhang, Z., Ding, S. C., Zai, C., Cui, X. Y., & Li, D. Y. (2021) · International Conference on Health Big Data and Smart Sports (HBDSS) · doi:10.1109/hbdss54392.2021.00035 · Cited by 10
Study-based evaluation of accuracy and usability of wearable devices in manual assembly
Tropschuh, B., Windecker, S., & Reinhart, G. (2022) · Production & Manufacturing Research · doi:10.1080/21693277.2022.2100505 · Cited by 11
“…comparative studies analyzed the data accuracy of, e.g. step counts, sleep duration, or estimated energy expenditure (EEE) recorded by different wearable devices, e.g. Fitbit One and Zip, Jawbone UP, or Nike Fuelband (Case et al., 2015; Ferguson et al., 2015; Lee et al., 2014; Wallen et al., 2016).”
BackgroundAssessment of the MyWellness Key accelerometer in people with type 2 diabetes
McGinley, S. K., Armstrong, M. J., Khandwala, F., Zanuso, S., & Sigal, R. J. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0169 · Cited by 10
Evaluating Low-cost Activity Trackers for Use in Large-scale Data Gathering of Forestry Workers
Bowen, J., Hinze, A., Cunningham, S. J., & Parker, R. (2015) · Australian Conference on Computer-Human Interaction (OzCHI) · doi:10.1145/2838739.2838741 · Cited by 10
Floegel, T. A., Allen, K. D., & Buman, M. P. (2018) · Geriatric Nursing · doi:10.1016/j.gerinurse.2018.10.001 · Cited by 10
Cole, T. S., Jahnke, H. K., Godzik, J., Morgan, C. D., Nakaji, P., & Little, A. S. (2019) · Pituitary · doi:10.1007/s11102-019-00946-y · Cited by 10
Energy Requirement Methodology
DeLany, J. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-802928-2.00004-7 · Cited by 10
Whelan, M., Kingsnorth, A. P., Orme, M. W., Sherar, L. B., & Esliger, D. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-018282 · Cited by 10
“The second article that you mentioned studied the validity of several devices in controlled conditions for a short period (69 minutes)(Lee et al, 2014) .”
BackgroundMethodInfluentialChoi, J. W., & Fukuoka, Y. (2018) · Women & Health · doi:10.1080/03630242.2018.1434588 · Cited by 9
“Buddies received a Fitbit Zip, and the Fitbit app was installed on their mobile phones.”
BackgroundInfluentialOomen, J., Arts, D., Sperling, M., & Vos, S. B. (2018) · Technology in Society · doi:10.1016/j.techsoc.2018.09.001 · Cited by 9
Marutani, Y., Konda, S., Ogasawara, I., Yamasaki, K., Yokoyama, T., Maeshima, E., & Nakata, K. (2022) · Sensors · doi:10.3390/s22072577 · Cited by 10
“The most popular consumer wearable is the watch-type sensor worn on the wrist, which allows the physical and physiological indices of daily living, exercise, and sports activity to be recorded [18,19].”
BackgroundCoşkun, A. (2019) · The Design Journal · doi:10.1080/14606925.2019.1634447 · Cited by 10
“Fitbit One is selected because its accuracy is very high among other commercial products (Lee, Kim, and Welk 2014).”
BackgroundPathare, N. C., Conroy, J. P., Gillard, A., & Hansen, M. (2019) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/cpt.0000000000000115 · Cited by 9
“Comparisons between research-grade accelerometers/multisensor devices and consumer-level activity monitors such as Fitbit devices have shown that Fitbit devices are valid in measuring step counts and energy expenditure.(27,28) Within each activity that was measured in the study, the Fitbit device had the strongest val…”
BackgroundPhysical activity in women of reproductive age in a transitioning rural Polish population
Lee, K. M. N., Rogers, M. P., Galbarczyk, A., Grazyna Jasienska, A., & Clancy, K. B. H. (2019) · American Journal of Human Biology · doi:10.1002/ajhb.23231 · Cited by 9
Soldier safety and performance through wearable devices
Murdock, R. C., & Hagen, J. A. (2018) · Micro- and Nanotechnology Sensors, Systems, and Applications · doi:10.1117/12.2304899 · Cited by 8
Giordanengo, A., Öztürk, P., Hansen, A. H., Årsand, E., Grøttland, A., & Hartvigsen, G. (2018) · JMIR Diabetes · doi:10.2196/10431 · Cited by 10
“…factors lead to these information gaps (1) sensors and wearables used by the patients are not well calibrated, imprecise or even defective [12,13], (2) sensors and wearables are incorrectly operated by the patients [14], (3) patients make errors when registering data manually, and forget to…”
BackgroundMiller, C. K., King, D., Nagaraja, H. N., Fujita, K., Cheavens, J. S., & Focht, B. C. (2023) · Journal of Behavioral Medicine · doi:10.1007/s10865-023-00406-w · Cited by 10
Düking, P., Ruf, L., Altmann, S., Thron, M., Kunz, P., & Sperlich, B. (2024) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2024.351 · Cited by 10
“To provide an indicator of the overall measurement error, mean absolute percent errors (MAPE) were calculated as previously performed (Lee et al., 2014).”
MethodSears, T., Alvalos, E., Lawson, S., McAlister, I. P., Eschbach, L. C., & Bunn, J. A. (2017) · International journal of exercise science · Cited by 8
Heart Rate Alters, But Does Not Improve, Calorie Predictions in Fitbit Activity Monitors
Montoye, A. H. K., Vusich, J., Mitrzyk, J., & Wiersma, M. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0003 · Cited by 8
Wilbur, R. E., Griffin, J. S., Sorensen, M., & Furberg, R. (2018) · JMIR Research Protocols · doi:10.2196/10215 · Cited by 7
“The use of accelerometers and heart rate monitors to record energy expenditure and other measures of physical activity is not new, but improved technology, including media sharing, has rendered the products more reliable, reducing cost and increasing their popularity among consumers [13].”
Enhancing energy balance education through physical education and self-monitoring technology
Chen, S., Zhu, X., Kim, Y., Welk, G. J., & Lanningham‐Foster, L. (2015) · European Physical Education Review · doi:10.1177/1356336x15588901 · Cited by 8
“Although the SWA utilized in this study was expensive (as a research device), affordable consumer-based tools with similar accuracy can be adopted for schools and families to utilize (Lee et al., 2014).”
MethodSelf-citationMotivational Aspects and Critical Issues of a Pedometer Intervention in Adolescents
Suchert, V., Steinvoord, K., Schwarz, J., Isensee, B., & Krieger, C. (2016) · Health Promotion Practice · doi:10.1177/1524839916667273 · Cited by 7
Montoye, A. H. K., & Mitrzyk, J. R. (2018) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2018.1539739 · Cited by 7
Zhang, P., Burns, R. D., Fu, Y., Godin, S., & Byun, W. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16203812 · Cited by 7
Thompson, D., Angel, M. D., Nunes, M. A., Gonzalez, J. T., Betts, J. A., & Peacock, O. J. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70079 · Cited by 6
RETRACTED: Experiment of biological pulse sensor and its application in physical education
Zhong, F. (2020) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2020.103781 · Cited by 6
RetractedZhang, Y., Bornkamp, N., Hivert, M., Oken, E., & James, P. (2024) · JMIR Pediatrics and Parenting · doi:10.2196/59159 · Cited by 6
“Fitbit uses a proprietary algorithm to calculate steps and categorizes activity intensity into 4 levels—very active, moderately active, lightly active, and sedentary, at the minute level [30,31].”
Social isolation is closely linked to a marked reduction in physical activity in male mice
Clemenza, K., Weiss, S., Cheslack‐Postava, K., Kandel, D. B., Kandel, E. R., & Levine, A. A. (2020) · Journal of Neuroscience Research · doi:10.1002/jnr.24777 · Cited by 8
“With the advent of commercially available and scientifically validated activity monitoring devices, such as the Fitbit (Lee et al., 2014; Vooijs et al., 2014), research can advance beyond self-reporting, allowing for more accurate data regarding individual activity levels.”
BackgroundData from Digital Health Devices Informs Ideal Cardiovascular Health
Leopold, J. A., Davis, R. B., & Antman, E. M. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11030189 · Cited by 6
Pinkston, M. M., Busch, A. M., Stein, M. D., Baker, J. V., Caviness, C. M., Herman, D. S., Weisberg, R. B., Abrantes, A. M., & Uebelacker, L. A. (2022) · Contemporary Clinical Trials · doi:10.1016/j.cct.2022.106842 · Cited by 6
Peiris, C. L., Cumming, T. B., Kramer, S. F., Johnson, L. G., Taylor, N. F., & Shields, N. (2016) · Journal of Intellectual & Developmental Disability · doi:10.3109/13668250.2016.1260100 · Cited by 6
Applicability of consumer activity monitor data in marathon events: an exploratory study
Constantinou, V., Felber, A. E., & Chan, J. L. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1366560 · Cited by 5
Heydenreich, J., Schütz, Y., Melzer, K., & Kayser, B. (2019) · Current Issues in Sport Science (CISS) · doi:10.15203/ciss_2019.003 · Cited by 6
MacDonald, M. J., Fawkner, S. G., Niven, A. G., & Rowe, D. A. (2019) · Pediatric Exercise Science · doi:10.1123/pes.2018-0213 · Cited by 6
Adamakis, M. (2020) · Sport Sciences for Health · doi:10.1007/s11332-020-00654-2 · Cited by 7
Sitthipornvorakul, E., Waongenngarm, P., Lohsoonthorn, V., & Janwantanakul, P. (2020) · Work · doi:10.3233/wor-203206 · Cited by 6
Sports medicine: bespoke player management
Stuart, S., Powell, D., Marshall, S. J., Clark, C. C. T., Martini, D. N., Johnston, W., & Godfrey, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00021-1 · Cited by 6
(2019) · CIN Computers Informatics Nursing · doi:10.1097/01.ncn.0000576724.96272.9f · Cited by 6
Salzwedel, A., Rabe, S., Zahn, T., Neuwirth, J., Eichler, S., Haubold, K., Wachholz, A., Reibis, R. K., & Völler, H. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7192 · Cited by 6
“Therefore, validity and reliability of these systems cannot be assumed [17-20].”
Støve, M. P., & Larsen, B. T. (2020) · European Journal of Physiotherapy · doi:10.1080/21679169.2019.1628300 · Cited by 5
Wang, L., Chen, P., Jiang, A., Zhang, F., & Wu, Z. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1539369 · Cited by 6
Karpman, J., Gross, D. P., Manns, P. J., & Tomkins‐Lane, C. (2020) · Work · doi:10.3233/wor-203164 · Cited by 5
“In the past, wearable devices have been used to determine cut points or activity levels on a day-to-day basis [5, 8, 15] or to compare energy expenditure results, [7, 13, 14, 27] but we have not found studies that specifically compared device output and maximal performance.”
An Opinion Regarding Equivalence Testing for Evaluating Measurement Agreement
Adamakis, M. (2019) · Journal of Scientific Research and Reports · doi:10.9734/jsrr/2019/v24i530163 · Cited by 5
“In that initial approach [1], as well as some of the following studies [2-4], equivalence was supported with the use of 90% confidence interval (CI), obtained from a mixed ANOVA.”
MethodKymäläinen, H., Hujala, T., Häggström, C., & Malinen, J. (2023) · International Journal of Forest Engineering · doi:10.1080/14942119.2023.2216113 · Cited by 6
“Accuracy of wearables has shown variation between different devices demonstrating a 9–30 % variation when evaluating accuracy on physical activity, heart rate, and energy consumption (Lee et al. 2014; Yetisen et al. 2018).”
BackgroundValidation Study of Physical Activity and Sedentary Behavior in African-American Men and Women
Hicks, J., Adams-Campbell, L. L., Lu, J., Mills, M. G., & Dash, C. (2023) · Journal of Racial and Ethnic Health Disparities · doi:10.1007/s40615-023-01734-y · Cited by 5
Adamakis, M. (2017) · Journal of Mobile Technology in Medicine · doi:10.7309/jmtm.6.1.4 · Cited by 5
Daily Step Count as a Simple Marker of Disease Severity in Hypertrophic Cardiomyopathy
Sweeting, J., Ingles, J., Ball, K., & Semsarian, C. (2018) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.12.012 · Cited by 5
Edwardson, C. L., Davies, M. J., Khunti, K., Yates, T. E., & Rowlands, A. V. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2017-0001 · Cited by 6
Assessing the Measurement Properties of the Fitbit Zip® Among Adults Living With HIV
Dagenais, M., Salbach, N. M., Brooks, D., & O’Brien, K. K. (2020) · Journal of Physical Activity and Health · doi:10.1123/jpah.2019-0242 · Cited by 5
Identifying ActiGraph non-wear time in pregnant women with overweight or obesity
Leonard, K. S., Pauley, A. M., Hohman, E. E., Guo, P., Rivera, D. E., Savage, J. S., Buman, M. P., & Downs, D. S. (2020) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2020.08.003 · Cited by 5
Díaz-Quesada, G., Puga-González, E., & Galiano, I. M. M. (2021) · JUMP · doi:10.17561/jump.n3.2 · Cited by 5
Elgendi, M., Wu, W., Guan, C., & Menon, C. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1237043 · Cited by 7
“Researchers could follow previous studies (62, 63) that pre-defined an equivalence zone of +10% of the reference mean, and perform a statistical test to determine whether the 90% confidence interval from the estimations falls within the equivalence zone with 95% precision (a 1⁄4 0:05).”
MethodOutputs Available from Objective Monitors
Tudor‐Locke, C. (2016) · Springer series on epidemiology and public health · doi:10.1007/978-3-319-29577-0_3 · Cited by 5
Miller, T. W. (2017) · Internet Journal of Allied Health Sciences and Practice · doi:10.46743/1540-580x/2017.1604 · Cited by 5
“Results: After the 36-week intervention program, results revealed qualitative improvements in the (1) active minutes, (2) steps taken and (3) miles walked by the subject.”
Result
Metadata
- Authors
- LEE, J.-M., KIM, Y., & WELK, G. J.
- Affiliations
- University of Nebraska at Omaha (US)
- Iowa State University (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2014-09
- Volume
- 46
- Issue
- 9
- Pages
- 1840-1848
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2095561638
- Cited by
- 401
- References
- 22
- Citations by year
- 2026: 6 · 2025: 11 · 2024: 10 · 2023: 13 · 2022: 17 · 2021: 19 · 2020: 29 · 2019: 51 · 2018: 68 · 2017: 67 · 2016: 61 · 2015: 39 · 2014: 9
- FWCI
- 39.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, daily energy expenditure, free-living conditions, Fitbit, ActiGraph, indirect calorimetry, equivalence testing
- MeSH terms
- Adult, Basketball, Energy Metabolism, Exercise Test, Female, Humans, Male, Motor Activity, Oxygen Consumption, Running, Walking, Monitoring, Ambulatory, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review