Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accelerometers that provide triaxial measured acceleration data are now available. However, equivalence of output between brands cannot be assumed and testing is necessary to determine whether features of the acceleration signal are interchangeable. PURPOSE: This study aimed to establish the equivalence of output between two brands of monitor in a laboratory and in a free-living environment. METHODS: For part 1, 38 adults performed nine laboratory-based activities while wearing an ActiGraph GT3X+ and GENEActiv (Gravity Estimator of Normal Everyday Activity) at the hip. For part 2, 58 children age 10-12 yr wore a GT3X+ and GENEActiv at the hip for 7 d in a free-living setting. RESULTS: For part 1, the magnitude of time domain features from the GENEActiv was greater than that from the GT3X+. However, frequency domain features compared well, with perfect agreement of the dominant frequency for 97%-100% of participants for most activities. For part 2, mean daily acceleration measured by the two brands was correlated (r = 0.93, P < 0.001, respectively) but the magnitude was approximately 15% lower for the GT3X+ than that for the GENEActiv at the hip. CONCLUSIONS: Frequency domain-based classification algorithms should be transferable between monitors, and it should be possible to apply time domain-based classification algorithms developed for one device to the other by applying an affine conversion on the measured acceleration values. The strong relation between accelerations measured by the two brands suggests that habitual activity level and activity patterns assessed by the GENE and GT3X+ may compare well if analyzed appropriately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · cited 1×
“A key recommendation from the 2009 Objective Measurement of Physical Activity Meeting cosponsored by the National Institutes of Health and American College of Sports Medicine was that monitor data should be collected and saved as raw signals, with data transformation carried out after processing to facilitate comparis…”
MethodPhysical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Self-citationProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124 · cited 2×
“’’ These counts are not comparable between different models of monitor because of differences in processing, filtering, and scaling of the measured acceleration signal (15).”
BackgroundMethod
Cited by
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Self-citationMerikangas, K. R., Swendsen, J., Hickie, I. B., Cui, L., Shou, H., Merikangas, A. K., Zhang, J., Lamers, F., Crainiceanu, C., Volkow, N. D., et al. (2019) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2018.3546 · Cited by 231
Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001435 · Cited by 187
Self-citationComparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.
Scott, J. J., Rowlands, A. V., Cliff, D. P., Morgan, P. J., Plotnikoff, R. C., & Lubans, D. R. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.04.017 · Cited by 120
Self-citationMielke, G. I., de Almeida Mendes, M., Ekelund, U., Rowlands, A. V., Reichert, F. F., & Crochemore‐Silva, I. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14416 · Cited by 26
“Afterwards, participants performed eight activities for 5 min each in the following sequence: (1) sitting in a chair using a computer; (2) standing on the floor using mobile phone; (3) circuit, which included sitting, putting on shoes, standing, moving eight light objects on a desk, texting on a mobile phone and sitti…”
MethodSelf-citation
Metadata
- Authors
- Rowlands, A. V., Fraysse, F., Catt, M., Stiles, V. H., Stanley, R. M., Eston, R. G., & Olds, T. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2015-01
- Volume
- 47
- Issue
- 1
- Pages
- 201-210
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2039665130
- Cited by
- 60
- References
- 3
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors. https://app.cochat.ai/papers/10.1249/mss.0000000000000394
- The paper
- Rowlands, A. V., Fraysse, F., Catt, M., Stiles, V. H., Stanley, R. M., Eston, R. G., & Olds, T. S. (2015). Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.