Criterion Validity of Competing Accelerometry-Based Activity Monitoring Devices
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to examine the comparative and criterion validity of the three activity monitors in relation to a portable metabolic analyzer (Oxycon Mobile (OM)) in adults. METHODS: A total of 52 adults age 18-40 yr each performed a series of 15 activities for 5 min each, with 1-min resting intervals between different activities. Participants completed the trials while wearing the three activity monitors and while being measured with the OM. Estimates of energy expenditure (EE) were obtained from the ActiGraph (one based on the vertical axis and the other from vector magnitude) as well as from the activPAL (AP) and the Core Armband (CA). The EE estimates were converted into MET(RMR) values by standardizing EE values with each person's resting metabolic rate and then temporarily matched to facilitate minute-by-minute comparisons. Equivalence testing and mean absolute percent errors (MAPE) were used to evaluate the agreement. RESULTS: MET(RMR) values from the CA were significantly equivalent to those from the OM for the overall group comparison (90% confidence interval (CI), 3.65 and 3.85 MET(RMR)) and vigorous intensity (90% CI, 8.27 and 10.10 MET(RMR)). The CA had the smallest MAPE for moderate (20.7%) and vigorous (14.5%) intensity, but the AP had smaller MAPE for sedentary activities (27.4%) and light (24.7%) intensity activities. CONCLUSIONS: The CA showed good agreement relative to the OM for the overall group comparison and for moderate and vigorous activities. The AP, in contrast, was the most accurate for sedentary and light activities. The combined use of the CA and AP may yield more accurate estimates of EE than using a single monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873 · cited 1×
“Standing is an activity construct that is distinct from sedentary behavior (3), and a recent cohort study (19) found that higher levels of time spent standing led to reductions in mortality rates.”
BackgroundComparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360 · cited 2×
“However, using this equation has been a well-accepted practice for validation studies (16,37).”
MethodValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703 · cited 1×
“Concerted efforts have been made in recent years to establish best practice guidelines for using objective measurement tools (5,23) and self-report measures (1,36).”
BackgroundValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1×
“Greater detail on equivalence testing is provided in our previous articles using this method (22,39).”
MethodSelf-citationImproving self-reports of active and sedentary behaviors in large epidemiologic studies
Matthews, C. E., Moore, S. C., George, S. M., Sampson, J., & Bowles, H. R. (2012) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e31825b34a0 · Cited by 211 · cited 1×
“Past studies have used the AP as a criterion measure of activity postures when validating other types of accelerometers (27) and selfreport methods (8,24).”
MethodSlootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69 · cited 1×
“studies have been carried out to determine the validity of the ActiGraph for estimating EE (2,32), intensity-specific PA time (13,33), or both (6) for adults and older adults (12).”
Background
Cited by
Lobelo, F., Rohm Young, D., Sallis, R., Garber, M. D., Billinger, S. A., Duperly, J., Hutber, A., Pate, R. R., Thomas, R. J., Widlansky, M. E., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000559 · Cited by 402
A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement
DIXON, P. M., SAINT-MAURICE, P. F., KIM, Y., HIBBING, P., BAI, Y., & WELK, G. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001481 · Cited by 227
Self-citationDuvivier, B. M. F. M., Schaper, N. C., Hesselink, M. K. C., van Kan, L., Stienen, N., Winkens, B., Koster, A., & Savelberg, H. H. C. M. (2017) · Diabetologia · doi:10.1007/s00125-016-4161-7 · Cited by 212
Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001435 · Cited by 187
“We selected ±10% of the mean as our proposed equivalence zone as in previous studies comparing activity monitors (31, 32).”
Metadata
- Authors
- KIM, Y., & WELK, G. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2015-11
- Volume
- 47
- Issue
- 11
- Pages
- 2456-2463
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2086827110
- Cited by
- 41
- References
- 7
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Criterion Validity of Competing Accelerometry-Based Activity Monitoring Devices. https://app.cochat.ai/papers/10.1249/mss.0000000000000691
- The paper
- KIM, Y., & WELK, G. J. (2015). Criterion Validity of Competing Accelerometry-Based Activity Monitoring Devices. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000691
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.