Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter?
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study aimed to determine the agreement between outputs from contemporaneous measures of acceleration from wrist-worn GENEActiv and ActiGraph accelerometers when processed using the GGIR open source package. METHODS: Thirty-four participants wore a GENEActiv and an ActiGraph GT3X+ on their nondominant wrist continuously for 2 d to ensure the capture of one 24-h day and one nocturnal sleep. GENEActiv.bin files and ActiGraph .csv files were analyzed with R-package GGIR version 1.2-0. Key outcome variables were as follows: wear time, average magnitude of dynamic wrist acceleration (Euclidean norm minus one [ENMO]), percentile distribution of accelerations, time spent across acceleration levels in a 40-mg resolution, time in moderate-to-vigorous physical activity (MVPA: total, 10-min bouts), and duration of nocturnal sleep. RESULTS: There was a high agreement between accelerometer brands for all derived outcomes (wear time, MVPA, and sleep; intraclass correlation coefficient [ICC] > 0.96), ENMO (ICC = 0.99), time spent across acceleration levels (ICC > 0.93), and accelerations ≥50th percentile of the distribution (ICC > 0.82). ENMO (mean ± SD, GENEActiv = 29.9 ± 20.7 mg, ActiGraph = 27.8 ± 21.4 mg) and accelerations between the 5th and the 75th percentile of the distribution measured by the GENEActiv were significantly higher than those measured by the ActiGraph. Correspondingly, the number of minutes recorded between 0 and 40 mg was significantly greater for the ActiGraph (745 min cf. 734 min), and the number of minutes recorded between 40 and 80 mg was significantly greater for the GENEActiv (110 min cf. 105 min). CONCLUSION: Derived outcomes (wear time, MVPA, and sleep) were similar between brands. Brands compared well for acceleration magnitudes >50-80 mg but not lower magnitudes indicative of sedentary time. Caution is advised when comparing the magnitude of ENMO between brands, but there was a high consistency between brands for the ranking of individuals for activity and sleep outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
National Sleep Foundation's sleep time duration recommendations: methodology and results summary.
Hirshkowitz, M., Whiton, K., Albert, S. M., Alessi, C., Bruni, O., DonCarlos, L., Hazen, N., Herman, J., Katz, E. S., Kheirandish-Gozal, L., et al. (2015) · Sleep Health · doi:10.1016/j.sleh.2014.12.010 · Cited by 4,404 · cited 2×
“The number of participants who met MVPA guidelines (6, 22) and recently 187 developed sleep guidelines (13) were determined for data from both monitors.”
BackgroundMethodLetter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Healy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-2046 · Cited by 1,465
Adjusting for multiple testing when reporting research results: the Bonferroni vs Holm methods.
Aickin, M., & Gensler, H. (1996) · American Journal of Public Health · doi:10.2105/ajph.86.5.726 · Cited by 1,346
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744 · cited 2×
“Two commercially 54 available research grade wrist-worn accelerometers that are widely used globally are the 55 GENEActiv and the ActiGraph (5, 10, 18, 21).”
BackgroundMethodValidation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Self-citation
Cited by
Migueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
Self-citationAn open resource for transdiagnostic research in pediatric mental health and learning disorders
Alexander, L. M., Escalera, J., Ai, L., Andreotti, C., Febre, K., Mangone, A., Vega-Potler, N., Langer, N., Alexander, A., Kovacs, M., et al. (2017) · Scientific Data · doi:10.1038/sdata.2017.181 · Cited by 651
Estimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001435 · Cited by 187
“On the basis of our previous work comparing GGIR physical activity outputs from the GENEActiv and the ActiGraph (20), we anticipated that the SD of the differences between the log transformed outputs from the two accelerometers would be less than 0.”
InfluentialSelf-citationMüller-Riemenschneider, F., Petrunoff, N., Yao, J., Ng, A., Sia, A., Ramiah, A., Wong, M., Han, J., Tai, B. C., & Uijtdewilligen, L. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-00941-8 · Cited by 99
Metadata
- Authors
- ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-10
- Volume
- 48
- Issue
- 10
- Pages
- 1935-1941
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2381952344
- Cited by
- 137
- References
- 7
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter? https://app.cochat.ai/papers/10.1249/mss.0000000000000978
- The paper
- ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2016). Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter? Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000978
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.