CoChat

Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter?

Open access
ROWLANDS, ALEX V., YATES, TOM, DAVIES, MELANIE, KHUNTI, KAMLESH, EDWARDSON, CHARLOTTE L. · 2016 · Medicine & Science in Sports & Exercise
Cited by 137

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: This study aimed to determine the agreement between outputs from contemporaneous measures of acceleration from wrist-worn GENEActiv and ActiGraph accelerometers when processed using the GGIR open source package. METHODS: Thirty-four participants wore a GENEActiv and an ActiGraph GT3X+ on their nondominant wrist continuously for 2 d to ensure the capture of one 24-h day and one nocturnal sleep. GENEActiv.bin files and ActiGraph .csv files were analyzed with R-package GGIR version 1.2-0. Key outcome variables were as follows: wear time, average magnitude of dynamic wrist acceleration (Euclidean norm minus one [ENMO]), percentile distribution of accelerations, time spent across acceleration levels in a 40-mg resolution, time in moderate-to-vigorous physical activity (MVPA: total, 10-min bouts), and duration of nocturnal sleep. RESULTS: There was a high agreement between accelerometer brands for all derived outcomes (wear time, MVPA, and sleep; intraclass correlation coefficient [ICC] > 0.96), ENMO (ICC = 0.99), time spent across acceleration levels (ICC > 0.93), and accelerations ≥50th percentile of the distribution (ICC > 0.82). ENMO (mean ± SD, GENEActiv = 29.9 ± 20.7 mg, ActiGraph = 27.8 ± 21.4 mg) and accelerations between the 5th and the 75th percentile of the distribution measured by the GENEActiv were significantly higher than those measured by the ActiGraph. Correspondingly, the number of minutes recorded between 0 and 40 mg was significantly greater for the ActiGraph (745 min cf. 734 min), and the number of minutes recorded between 40 and 80 mg was significantly greater for the GENEActiv (110 min cf. 105 min). CONCLUSION: Derived outcomes (wear time, MVPA, and sleep) were similar between brands. Brands compared well for acceleration magnitudes >50-80 mg but not lower magnitudes indicative of sedentary time. Caution is advised when comparing the magnitude of ENMO between brands, but there was a high consistency between brands for the ranking of individuals for activity and sleep outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000000978

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 137

Metadata

Authors
ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L.
Venue
Medicine & Science in Sports & Exercise
Published
2016-10
Volume
48
Issue
10
Pages
1935-1941
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2381952344
Cited by
137
References
7
FWCI
8.67
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter? https://app.cochat.ai/papers/10.1249/mss.0000000000000978
The paper
ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2016). Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter? Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000978

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.