Accuracy of Wristband Activity Monitors during Ambulation and Activities
Abstract
Purpose The main purpose of this study was to examine the accuracy of wristband activity monitors on measuring step counts at prescribed speeds on a treadmill and under short bouts of common daily activities. Methods Thirty healthy young adults wore three wristband activity monitors on both wrists while walking or jogging on a treadmill at different speeds (54, 80, 107, and 134 m·min) and performing six different common daily activities for 5 min each. The monitors included the Fitbit Flex, the Garmin Vivofit, and the Jawbone UP. The common daily activity conditions included two sitting activities (playing a tablet computer game and folding laundry), two walking activities (pushing a stroller, carrying a bag), and two stair climbing activities (down and up). Absolute percentage error (APE) scores were computed to examine the accuracy between actual observed steps and monitor-detected steps. Results Under the treadmill condition, the APE ranged between 1.5% and 9.6%. Accuracy was improved at faster speeds (134 m·min) for all the monitors (APE 33%) when pushing a stroller. Higher APE was observed when worn on the dominant wrist under the common daily activity conditions. Conclusions The wristband activity monitors examined were more accurate for measuring step counts between 80 and 134 m·min as compared with a slower speed. Accuracy under each common daily activity condition ranged widely between monitors and activity, with less error when worn on the nondominant wrist. These r…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wrist step counters do not count steps when the wrist is stationary, such as when pushing a stroller or holding onto treadmill hand rails.
“Wrist step counters do not count steps when the wrist is stationary. For example, they do not record steps taken when pushing a stroller [28], or holding onto treadmill hand rails.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [28]
Wrist-worn step counters record invalid steps when folding laundry or gesturing while talking.
“Furthermore, wrist-worn step counters record invalid steps when folding laundry [28], or gesturing while talking.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [28]
Three wrist devices (Fitbit Flex, Garmin Vivofit, and Jawbone Up) were quite accurate (absolute percent error for steps = 1.5-9.6%) during treadmill walking and running at 54-134 m/min.
“However, a study by Chen et al. [28] reported that three wrist devices (Fitbit flex, Garmin Vivofit, and Jawbone Up) were quite accurate (absolute percent error for steps = 1.5–9.6%) during treadmill walking and running at 54–134 m/min.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [28]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · see citing works
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542 · see citing works
Step Counting: A Review of Measurement Considerations and Health-Related Applications
Bassett, D. R., Toth, L. P., LaMunion, S. R., & Crouter, S. E. (2017) · Sports Medicine · doi:10.1007/s40279-016-0663-1 · Cited by 460 · see citing works
Current State of Commercial Wearable Technology in Physical Activity Monitoring 2015-2017
Bunn, J., Navalta, J. W., Fountaine, C. J., & Reece, J. (2018) · International Journal of Exercise Science · doi:10.70252/njqx2719 · Cited by 194 · see citing works
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001569 · Cited by 154 · see citing works
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116 · see citing works
Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0222569 · Cited by 53 · see citing works
Femiano, R., Werner, C., Wilhelm, M., & Eser, P. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.035 · Cited by 31 · see citing works
“investigated the accuracy of step counts from three commercial wristband monitors (Fitbit Flex, Garmin Vivo fit, Jawbone UP) during walking at different speeds, six different activities including stair climbing and two sitting tasks.[28] Our tested algorithms had comparable accuracies to the above-cited commercial dev…”
BackgroundMethodCongruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T. (2018) · International Journal of Exercise Science · doi:10.70252/ubbt6886 · Cited by 16 · see citing works
“com 581 similar to the current study (2, 5, 10, 13, 18).”
BackgroundClevenger, K. A., Molesky, M. J., Vusich, J., & Montoye, A. H. K. (2019) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2019.1577737 · Cited by 13 · see citing works
- Authors
- CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J.
- Affiliations
- Northwestern University (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-10
- Volume
- 48
- Issue
- 10
- Pages
- 1942-1949
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2364933950
- Cited by
- 90
- References
- 1
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 2 · 2023: 8 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 20 · 2018: 13 · 2017: 6 · 2016: 3
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- step count accuracy, wearable activity trackers, daily activities, stair climbing
- MeSH terms
- Activities of Daily Living, Exercise Test, Female, Humans, Jogging, Male, Wrist, Exercise, Walking, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review