Validity of six consumer-level activity monitors for measuring steps in patients with chronic heart failure
Open accessAbstract
INTRODUCTION: Although numerous activity trackers have been validated in healthy populations, validation is lacking in chronic heart failure patients who normally walk at a slower pace, making it difficult for researchers and clinicians to implement activity monitors during physical activity interventions. METHODS: Six consumer-level activity monitors were validated in a 3-day field study in patients with chronic heart failure and healthy individuals under free living conditions. Furthermore, the same devices were evaluated in a lab-based study during treadmill walking at speeds of 2.4, 3.0, 3.6, and 4.2 km·h-1. Concordance correlation coefficients (CCC) were used to evaluate the agreement between the activity monitors and the criterion, and mean absolute percentage errors (MAPE) were calculated to assess differences between each device and the criterion (MAPE <10% was considered as a threshold for validity). RESULTS: In the field study of healthy individuals, all but one of the activity monitors showed a substantial correlation (CCC ≥0.95) with the criterion device and MAPE <10%. In patients with heart failure, the correlation of only two activity monitors (Garmin vívofit 3 and Withings Go) was classified as at least moderate (CCC ≥0.90) and none of the devices had MAPE <10%. In the lab-based study at speeds 4.2 and 3.6 km·h-1, all activity monitors showed substantial to almost perfect correlations (CCC ≥0.95) with the criterion and MAPE in the range 1%-3%. However, at slower speeds of 3.0 and 2.4 km·h-1, the accuracy of all devices substantially deteriorated: their correlation with the criterion decreased below 90% and their MAPE increased to 4-8% and 10-45%, respectively. CONCLUSIONS: Even though none of the tested activity monitors fall within arbitrary thresholds for validity, most of them perform reasonably well enough to be useful tools that clinicians can use to simply motivate chronic heart failure patients to walk more.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Many validation studies have questioned the accuracy of raw sensor data and software algorithms.
“Many validation studies have questioned the accuracy of raw sensor data and software algorithms92–94.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [93]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 29,639 · see citing works
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O. D., et al. (2021) · PubMed · doi:10.1093/eurheartj/ehab670 · Cited by 19,618 · see citing works
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R. C., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,526 · see citing works
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · see citing works
2011 Compendium of Physical Activities: A Second Update of Codes and MET Values
AINSWORTH, B. E., HASKELL, W. L., HERRMANN, S. D., MECKES, N., BASSETT, D. R., TUDOR-LOCKE, C., GREER, J. L., VEZINA, J., WHITT-GLOVER, M. C., & LEON, A. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821ece12 · Cited by 6,317 · see citing works
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866 · see citing works
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064 · see citing works
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317 · see citing works
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · see citing works
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899 · see citing works
Piepoli, M. F., Conraads, V. M., Corrà, U., Dickstein, K., Francis, D. P., Jaarsma, T., McMurray, J. J. V., Pieske, B. M., Piotrowicz, E., Schmid, J., et al. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr017 · Cited by 748 · see citing works
Exercise-based cardiac rehabilitation for adults with heart failure
Long, L., Mordi, I. R., Bridges, C., Sagar, V. A., Davies, E. J., Coats, A. J. S., Dalal, H. M., Rees, K., Singh, S. J., & Taylor, R. S. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003331.pub5 · Cited by 558 · see citing works
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542 · see citing works
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · see citing works
ActiGraph and Actical Physical Activity Monitors
John, D., & Freedson, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399f5e · Cited by 353 · see citing works
Adherence of Heart Failure Patients to Exercise: Barriers and Possible Solutions
Conraads, V. M., Deaton, C., Piotrowicz, E., Santaularia, N., Tierney, S., Piepoli, M. F., Pieske, B. M., Schmid, J., Dickstein, K., Ponikowski, P. P., et al. (2012) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs048 · Cited by 322 · see citing works
Validity of activity monitors in health and chronic disease: a systematic review
Remoortel, H. V., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno‐Santos, E., Langer, D., Glendenning, G. A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277 · see citing works
Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites
TUDOR-LOCKE, C., BARREIRA, T. V., & SCHUNA, J. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000476 · Cited by 218 · see citing works
Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
Fokkema, T., Kooiman, T. J. M., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001146 · Cited by 212 · see citing works
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001471 · Cited by 205 · see citing works
Lee, J. A., Williams, S. M., Brown, D. D., & Laurson, K. R. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.981848 · Cited by 169 · see citing works
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Paul, S. S., Tiedemann, A., Hassett, L. M., Ramsay, E., Kirkham, C., Chagpar, S., & Sherrington, C. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000013 · Cited by 164 · see citing works
Relation of daily activity levels in patients with chronic heart failure to long-term prognosis
Walsh, J. T., Charlesworth, A., Andrews, R. V., Hawkins, M., & Cowley, A. J. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00141-0 · Cited by 144 · see citing works
Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting
Treacy, D., Hassett, L. M., Schurr, K., Chagpar, S., Paul, S. S., & Sherrington, C. (2017) · Physical Therapy · doi:10.1093/ptj/pzx010 · Cited by 141 · see citing works
Harris, T. J., Kerry, S., Limb, E. S., Victor, C. R., Iliffe, S., USSHER, M. H., Whincup, P. H., Ekelund, U., Fox-Rushby, J. A., Furness, C., et al. (2017) · PLoS Medicine · doi:10.1371/journal.pmed.1002210 · Cited by 132 · see citing works
How valid are wearable physical activity trackers for measuring steps?
An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J. M. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2016.1255261 · Cited by 131 · see citing works
Protocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124 · see citing works
Nolte, K., Herrmann‐Lingen, C., Wachter, R., Gelbrich, G., Düngen, H., Duvinage, A., Hoischen, N., Oehsen, K. V., Schwarz, S., Hasenfuss, G. P., et al. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487314526071 · Cited by 119 · see citing works
Accuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90 · see citing works
Moy, M. L., Janney, A. W., Nguyen, H. Q., Matthess, K. R., Cohen, M., Garshick, E., & Richardson, C. R. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.07.0091 · Cited by 81 · see citing works
John, D., Morton, A. L., ARGUELLO, D. J., Lyden, K. A., & Bassett, D. R. (2018) · Sensors · doi:10.3390/s18041206 · Cited by 74 · see citing works
Thorup, C. B., Andreasen, J. J., Sørensen, E. E., Grønkjær, M., Dinesen, B., & Hansen, J. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-011742 · Cited by 43 · see citing works
Influence of Pedometer Position on Pedometer Accuracy at Various Walking Speeds: A Comparative Study
Ehrler, F., Weber, C., & Lovis, C. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5916 · Cited by 37 · see citing works
Reduced customary activity in chronic heart failure: assessment with a new shoe-mounted pedometer
Hoodless, D. J., Stainer, K., Savic, N., Batin, P. D., Hawkins, M., & Cowley, A. J. (1994) · International Journal of Cardiology · doi:10.1016/0167-5273(94)90088-4 · Cited by 36 · see citing works
Ventilatory Determinants of Self-selected Walking Speed in Chronic Heart Failure
FIGUEIREDO, P., Ribeiro, P. A. B., Bona, R. L., et al. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318277968f · Cited by 32 · see citing works
Gait analysis in chronic heart failure: The calf as a locus of impaired walking capacity
Panizzolo, F. A., Maiorana, A., Naylor, L. H., et al. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.09.015 · Cited by 31 · see citing works
Větrovský, T., Cupka, J., Dudek, M., Kuthanova, B., Vetrovska, K., Čapek, V., & Bunc, V. (2018) · BMC Public Health · doi:10.1186/s12889-018-5520-8 · Cited by 31 · see citing works
Self-citationMethods for Activity Monitor Validation Studies: An Example With the Fitbit Charge
DeShaw, K. J., Ellingson, L. D., Bai, Y., Lansing, J. E., Perez, M., & Welk, G. J. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0017 · Cited by 28 · see citing works
Validity of Garmin Vívofit 1 and Garmin Vívofit 3 for School-Based Physical Activity Monitoring
Šimůnek, A., Dygrýn, J., Jakubec, L., Neuls, F., Frömel, K., & Welk, G. J. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2018-0019 · Cited by 27 · see citing works
Validity of Activity Tracker Step Counts during Walking, Running, and Activities of Daily Living
Toth, L. P., Park, S., Pittman, W. L., Sarisaltik, D., Hibbing, P. R., Morton, A. L., Springer, C. M., Crouter, S. E., & Bassett, D. R. (2018) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000057 · Cited by 25 · see citing works
Pedometer Accuracy in Patients with Chronic Heart Failure
Jehn, M., Schmidt‐Trucksäss, A., Schuster, T., Hanssen, H., Halle, M., & Köhler, F. (2010) · International Journal of Sports Medicine · doi:10.1055/s-0029-1243641 · Cited by 24 · see citing works
Šimůnek, A., Dygrýn, J., Gába, A., Jakubec, L., Stelzer, J., & Chmelík, F. (2016) · Acta Gymnica · doi:10.5507/ag.2016.014 · Cited by 23 · see citing works
Větrovský, T., Širanec, M., Pařenica, J., Gřiva, M., Stastny, J., Přeček, J., Pelouch, R., Bunc, V., Linhart, A., & Bělohlávek, J. (2017) · Journal of Translational Medicine · doi:10.1186/s12967-017-1257-x · Cited by 23 · see citing works
Self-citationBattery optimization in smartphones for remote health monitoring systems to enhance user adherence
Alshurafa, N. I., Eastwood, J., Nyamathi, S., Xu, W., Liu, J. J., & Sarrafzadeh, M. (2014) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/2674396.2674407 · Cited by 18 · see citing works
Shoemaker, M. J., Cartwright, K., Hanson, K., Serba, D., Dickinson, M. G., & Kowalk, A. (2017) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/cpt.0000000000000042 · Cited by 18 · see citing works
Adamakis, M. (2017) · Journal of Mobile Technology in Medicine · doi:10.7309/jmtm.6.1.4 · Cited by 5 · see citing works
Validity of Daily Physical Activity Measurements of Fitbit Charge 2
Figueroa, I. A., Lucio, N. D., Gamez, J. L., et al. (2018) · TopSCHOLAR (Western Kentucky University) · Cited by 3 · see citing works
Daily Dietary Intake and Energy Availability among Division I Collegiate Female Soccer Players
Moore, E. M., Torres-McGehee, T. M., Emerson, D. M., et al. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000476393.44464.59 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
- Authors
- Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J.
- Affiliations
- Charles University (CZ)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2019-09-13
- Volume
- 14
- Issue
- 9
- Pages
- e0222569
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC6743766
- OpenAlex
- W2972777558
- Cited by
- 53
- References
- 48
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 11 · 2022: 9 · 2021: 5 · 2020: 4
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Charles University Grant Agency (GAUK 1302317)
- Czech Health Research Council of the Ministry of Health of the Czech Republic (NV18-09-00146)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, step counting, chronic heart failure, device validation, wearable sensors, physical activity measurement, physical activity interventions
- MeSH terms
- Fitness Trackers, Adult, Aged, Chronic Disease, Exercise Test, Female, Heart Failure, Humans, Male, Reproducibility of Results, Exercise, Walking, Monitoring, Ambulatory, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review