Congruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Open accessAbstract
International Journal of Exercise Science 11(7): 575-584, 2018. To examine activity tracker accuracy for measuring steps, energy expenditure, and heart rate in controlled and free-living conditions. Forty participants performed four, five-minute stages (walking: 53.7 m∙min-1, 80.5 m∙min-1; running: 134.1 m∙min-1, 160.9 m∙min-1) while wearing the Fitbit Charge HR (FB) and the Mio FUSE (MF) activity trackers. Measurements included steps, energy expenditure (kcals), and heart rate (beats∙min-1). In addition to the FB and MF, participants wore the NL-1000 (NL) activity tracker during waking hours of the subsequent day. One way ANOVAs with Tukey’s post hoc analyses were performed to compare mean values for steps, kcals, and mean heart rate between the FB, MF, and criterion measures. Levels of agreement for heart rate with 95% confidence intervals were examined with Bland-Altman plots. Compared to criterion measures, the FB and MF underestimated steps and overestimated kcals at 53.7 m∙min-1 (FB: 12.7% for steps, 89.2% for kcals; MF: 15.8% for steps, 44.9% for kcals, p<.001) and 80.5 m∙min-1 (FB: 9.7% for steps, 69.9% for kcals; MF: 13.4% for steps, 32.0% for kcals, p<.001). During free-living conditions, the MF significantly underestimated steps by 30.0% (p<.05). Increasing exercise intensity is indicative of heightened accuracy for step detection and kcal estimation for the FB and MF, while decreasing heart rate accuracy for the FB. However, the MF performed poorly for estimating total daily activity.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dondzila et al found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.
“Dondzila et al [34] also looked at the Fitbit Charge HR and found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.”
From Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (2018) · cites this paper as [34]
Cites
2011 Compendium of Physical Activities: A Second Update of Codes and MET Values
AINSWORTH, B. E., HASKELL, W. L., HERRMANN, S. D., MECKES, N., BASSETT, D. R., TUDOR-LOCKE, C., GREER, J. L., VEZINA, J., WHITT-GLOVER, M. C., & LEON, A. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821ece12 · Cited by 6,317 · cited 1× · see citing works
“Energy expenditure output from the FB and MF were compared with kcals derived from kcals calculated via MET values of treadmill intensities (1).”
MethodSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 2× · see citing works
“Activity monitors have demonstrated success at facilitating positive physical activity behavior changes in diverse populations by providing self-monitoring, and supporting motivation and timely feedback (8).”
BackgroundLee, I.-M. M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., Katzmarzyk, P. T., & Kahlmeier, S. (2012) · BDJ · doi:10.1038/sj.bdj.2012.909 · Cited by 905 · see citing works
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360 · cited 1× · see citing works
“Numerous studies have explored wrist-worn Fitbit devices during various treadmill speeds (2, 5, 9, 10, 13, 15, 18, 25).”
BackgroundVariable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · cited 1× · see citing works
“An accurate tool to assess exercise heart rate (11), a Polar heart rate monitor (T31, Polar Electro Oy, Kempele, Finland) was worn around the chest of the participant with direct contact to the skin, transmitting data to the FT1 monitor to record heart rate data as a criterion measure during the treadmill protocol.”
MethodAccuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · cited 7× · see citing works
“Furthermore, there is a dearth of research on the Mio devices for any physical activity metric, other than heart rate (4, 20, 24, 28).”
BackgroundResultInfluentialDooley, E. E., Golaszewski, N. M., & Bartholomew, J. B. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7043 · Cited by 242 · cited 3× · see citing works
“ABSTRACT International Journal of Exercise Science 11(7): 575-584, 2018.”
BackgroundResultReliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
Fokkema, T., Kooiman, T. J. M., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001146 · Cited by 212 · cited 5× · see citing works
“com 581 similar to the current study (2, 5, 10, 13, 18).”
BackgroundResultInfluentialValidity of Consumer-Based Physical Activity Monitors for Specific Activity Types
Nelson, M. B., Kaminsky, L. A., Dickin, D. C., & Montoye, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 206 · see citing works
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202 · cited 1× · see citing works
“It is interesting to note the trend for waist-worn Fitbit devices in underestimating kcals (19, 23), with reference to wrist-worn Fitbit devices.”
BackgroundValidity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Paul, S. S., Tiedemann, A., Hassett, L. M., Ramsay, E., Kirkham, C., Chagpar, S., & Sherrington, C. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000013 · Cited by 164 · cited 1× · see citing works
“Older adults, however, were the target population in one study (9), who commonly demonstrate different gait patterns that influence activity tracker accuracy (21).”
BackgroundSushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152 · cited 6× · see citing works
“Interestingly, two studies (9, 25) reported MAPE >20% for walking speeds.”
BackgroundInfluentialEvaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148 · cited 4× · see citing works
“No studies exist comparing the FB to the MF (to the authors’ knowledge), yet the MF performed on par with previous research on Mio devices (4, 20), and better than the Mio Alpha in the studies concurrently compared to the FB (24, 28).”
BackgroundMethodResultInfluentialÉvaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142 · cited 1× · see citing works
“Mean absolute percent errors (MAPE) not exceeding 10%, in relation to manually tallied steps, has been identified as a threshold for acceptable agreement (26).”
BackgroundReid, R. E. R., Insogna, J. A., Carver, T. E., Comptour, A. M., Bewski, N. A., Sciortino, C. D., & Andersen, R. E. (2016) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.10.015 · Cited by 133 · cited 1× · see citing works
“7% to 47% (3, 6, 14, 22, 25, 27), influenced by the intensity and volume of activities engaged in.”
BackgroundHow valid are wearable physical activity trackers for measuring steps?
An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J. M. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2016.1255261 · Cited by 131 · cited 4× · see citing works
“There is limited research examining Fitbit devices in both free living and laboratory conditions (13, 18, 25).”
BackgroundInfluentialChu, A. H. Y., Ng, S. H.-X., Paknezhad, M., Gauterin, A., Koh, D. S. Q., Brown, M. S., & Müller‐Riemenschneider, F. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172535 · Cited by 121 · cited 1× · see citing works
“7% to 47% (3, 6, 14, 22, 25, 27), influenced by the intensity and volume of activities engaged in.”
BackgroundValidation of the Fitbit Wireless Activity Tracker for Prediction of Energy Expenditure
Sasaki, J. E., Hickey, A., Mavilia, M. G., Tedesco, J., John, D., Keadle, S. K., & Freedson, P. S. (2014) · Journal of Physical Activity and Health · doi:10.1123/jpah.2012-0495 · Cited by 116 · cited 1× · see citing works
“It is interesting to note the trend for waist-worn Fitbit devices in underestimating kcals (19, 23), with reference to wrist-worn Fitbit devices.”
BackgroundFloegel, T. A., Flórez-Pregonero, A., Hekler, E. B., & Buman, M. P. (2016) · The Journals of Gerontology Series A · doi:10.1093/gerona/glw098 · Cited by 108 · cited 3× · see citing works
“Interestingly, two studies (9, 25) reported MAPE >20% for walking speeds.”
BackgroundDominick, G. M., Winfree, K. N., Pohlig, R. T., & Papas, M. A. (2016) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6281 · Cited by 102 · cited 1× · see citing works
“7% to 47% (3, 6, 14, 22, 25, 27), influenced by the intensity and volume of activities engaged in.”
BackgroundAccuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90 · cited 3× · see citing works
“com 581 similar to the current study (2, 5, 10, 13, 18).”
BackgroundValidity of Commercial Activity Trackers in Children With Congenital Heart Disease
Voss, C., Gardner, R. F., Dean, P. H., & Harris, K. C. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.11.024 · Cited by 61 · cited 2× · see citing works
“One study utilizing the Charge HR (27) showed a 28% overestimation of steps, however the sample population was children with congenital heart disease, which likely influenced activity with smaller gait patterns, and thus, accuracy.”
BackgroundMethodEvaluation of accuracy and reliability of PulseOn optical heart rate monitoring device
Delgado-Gonzalo, R., Parák, J., Tarniceriu, A., Renevey, P., Bertschi, M., & Korhonen, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318391 · Cited by 55 · see citing works
Convergent Validity of 3 Low Cost Motion Sensors With the ActiGraph Accelerometer
McClain, J. J., Hart, T. L., Getz, R. S., & Tudor‐Locke, C. (2010) · Journal of Physical Activity and Health · doi:10.1123/jpah.7.5.662 · Cited by 31 · cited 2× · see citing works
“8% fewer minutes in moderate-vigorous physical activity, compared to Actigraph accelerometry (17).”
MethodResultHazell, T. J., Ellery, C. V. L., Cohen, T. R., Vanstone, C. A., Rodd, C. J., & Weiler, H. A. (2016) · Pediatric Research · doi:10.1038/pr.2016.133 · Cited by 2 · cited 1× · see citing works
“This device has demonstrated acceptable validity in controlled (12) and free-living conditions (17), with the NL reporting <4.”
Method
Flagged first, then by citations
3 of the 28 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
“[20,21,29,32,34,36,38,45,53,64-82] Wrist Discontinued 2015 Charge HR Fitbit”
BackgroundHeart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
“parallel to the blood vessel to measure the time difference as the blood pulse moves across the sensors to estimate external noise or MA [69].”
BackgroundReddy, R. K., Pooni, R., Zaharieva, D. P., Senf, B., El Youssef, J., Dassau, E., Doyle III, F. J., Clements, M. A., Rickels, M. R., Patton, S. R., et al. (2018) · JMIR mHealth and uHealth · doi:10.2196/10338 · Cited by 157 · see citing works
“Dondzila et al [34] also looked at the Fitbit Charge HR and found that with aerobic exercise under laboratory conditions, the Fitbit Charge HR underestimated the HR compared with a Polar chest strap, with higher error at slower speeds.”
Concurrent heart rate validity of wearable technology devices during trail running
Navalta, J. W., Montes, J., Bodell, N. G., Salatto, R. W., Manning, J. W., & DeBeliso, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238569 · Cited by 62 · see citing works
“Unfortunately, heart rate validity was not reported for the free living time frame [20].”
BackgroundMethodValidation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59 · see citing works
“Similarly, biases were systematically greater in arm-driven sports, though they remained under 1 bpm and negative, implying that the OH1 measures a (very slightly) lower HR than the criterion (▶table 1), as noted by others [14, 19, 21, 34] or not [16, 35].”
BackgroundJia, Y., Wang, W., Wen, D., Liang, L., Gao, L., & Lei, J. (2018) · PeerJ · doi:10.7717/peerj.5350 · Cited by 47 · see citing works
“found the wearable devices are only reliable in measuring the number of steps and distance, which can be used as health assessment indicators (Dondzila et al., 2018; Rozanski et al., 2018; Wen et al., 2017; Xie et al., 2018).”
MethodNavalta, J. W., Davis, D. W., Malek, E. M., Carrier, B., Bodell, N. G., Manning, J. W., Cowley, J. C., Funk, M. D., Lawrence, M. M., & DeBeliso, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-38329-w · Cited by 43 · see citing works
Ibrahim, N. S., Rampal, S., Lee, W. L., Pek, E. W., & Suhaimi, A. (2023) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-023-00693-z · Cited by 16 · see citing works
“Other studies have supported that HR measurement was accurate and reliable at low-and moderate-intensity exercise [67, 68] and vigorous-intensity exercise [25].”
Montes, J., Tandy, R. D., Young, J., Lee, S., & Navalta, J. W. (2019) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.7n.2p.30 · Cited by 10 · see citing works
Goodison, S. E., Barnum, J. D., Vermeer, M., Woods, D., Sitar, S. I., Shelton, S. R., & Jackson, B. A. (2020) · RAND Corporation eBooks · doi:10.7249/rra108-7 · Cited by 3 · see citing works
“The accuracy of wrist-worn fitness trackers has generally been found to be low, with some features, such as step count, showing higher validity than others, such as distance, energy expenditure, total sleep time, sleep efficiency, and heart rate (Dondzila et al., 2018; Evenson, Goto, and Furberg, 2015; Evenson and Spa…”
BackgroundHeart Rate Equivalency of the Fitbit Charge HR During Continuous Aerobic Exercise
Stock, J. M., Pohlig, R. T., Botieri, M. J., Edwards, D. G., & Dominick, G. M. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0009 · Cited by 1 · see citing works
Colonna, G., Hoye, J., de Laat, B., Stanley, G., Ibrahimy, A., Tinaz, S., & Morris, E. D. (2023) · JMIR Biomedical Engineering · doi:10.2196/51515 · Cited by 1 · see citing works
“In previous studies, Fitbit overestimated time spent on moderate to vigorous activity in clinical populations with functional limitations, compared to the criterion devices [26].”
BackgroundMassaroni, C., Silvestri, S., & Schena, E. (2024) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot61288.2024.10584238 · Cited by 1 · see citing works
Ubiquitous Assessment of the Recovery of Cancer Patients Using Consumer-Level Activity Trackers
Moreno, S., Damas, M., Rojas, I., Amezcua, V., Gutiérrez-Pastor, P., & Baños, O. (2018) · International Conference on Ubiquitous Computing and Ambient Intelligence (UCAmI) · doi:10.3390/proceedings2191204 · Cited by 1 · see citing works
“Regarding other measures of Fitbit such as heart rate, there is clear agreement in its low reliability and high sensitivity to artifacts and sensor displacement, so this data should be interpreted carefully [11,17,24].”
BackgroundSchipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2025) · doi:10.2196/preprints.87324 · Cited by 1 · see citing works
Schipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2026) · JMIR mhealth and uhealth · doi:10.2196/87324 · Cited by 1 · see citing works
- Authors
- Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T.
- ORCID
- Parker, Tonya
- Venue
- International Journal of Exercise Science
- Published
- 2018
- Volume
- 11
- Issue
- 7
- Pages
- 575-584
- ISSN
- 1939-795X (ISSN-L)
- OpenAlex
- W2787184052
- Cited by
- 16
- References
- 28
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2020: 3 · 2019: 3 · 2018: 4
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nd
- Locations
- International journal of exercise science (publishedVersion, cc-by-nd)
- TopSCHOLAR (Western Kentucky University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, measurement accuracy, step counting, energy expenditure estimation, heart rate monitoring, walking and running, free-living conditions, exercise intensity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review