Cited by 16Physical Activity and HealthContext-Aware Activity Recognition SystemsMobile Health and mHealth Applications

Congruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions

Open access
Dondzila, Christopher J., Lewis, Colleen, Lopez, Justin R., Parker, Tonya·2018·International Journal of Exercise Science

Abstract

International Journal of Exercise Science 11(7): 575-584, 2018. To examine activity tracker accuracy for measuring steps, energy expenditure, and heart rate in controlled and free-living conditions. Forty participants performed four, five-minute stages (walking: 53.7 m∙min-1, 80.5 m∙min-1; running: 134.1 m∙min-1, 160.9 m∙min-1) while wearing the Fitbit Charge HR (FB) and the Mio FUSE (MF) activity trackers. Measurements included steps, energy expenditure (kcals), and heart rate (beats∙min-1). In addition to the FB and MF, participants wore the NL-1000 (NL) activity tracker during waking hours of the subsequent day. One way ANOVAs with Tukey’s post hoc analyses were performed to compare mean values for steps, kcals, and mean heart rate between the FB, MF, and criterion measures. Levels of agreement for heart rate with 95% confidence intervals were examined with Bland-Altman plots. Compared to criterion measures, the FB and MF underestimated steps and overestimated kcals at 53.7 m∙min-1 (FB: 12.7% for steps, 89.2% for kcals; MF: 15.8% for steps, 44.9% for kcals, p<.001) and 80.5 m∙min-1 (FB: 9.7% for steps, 69.9% for kcals; MF: 13.4% for steps, 32.0% for kcals, p<.001). During free-living conditions, the MF significantly underestimated steps by 30.0% (p<.05). Increasing exercise intensity is indicative of heightened accuracy for step detection and kcal estimation for the FB and MF, while decreasing heart rate accuracy for the FB. However, the MF performed poorly for estimating total daily activity.

Integrity signals

Registry

Crossref · 10.70252/ubbt6886

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

3 of the 28 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T.
Venue
International Journal of Exercise Science
Published
2018
Volume
11
Issue
7
Pages
575-584
ISSN
1939-795X (ISSN-L)
OpenAlex
W2787184052
Cited by
16
References
28
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2020: 3 · 2019: 3 · 2018: 4
FWCI
1.73
Type
journal article
Language
en
Open access
Licence
cc-by-nd
Locations
  • International journal of exercise science (publishedVersion, cc-by-nd)
  • TopSCHOLAR (Western Kentucky University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
wearable activity trackers, measurement accuracy, step counting, energy expenditure estimation, heart rate monitoring, walking and running, free-living conditions, exercise intensity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review