Muscle Near-Infrared Spectroscopy Signals versus Venous Blood Hemoglobin Oxygen Saturation in Skeletal Muscle
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Purpose The study aimed to examine the relationship between near-infrared spectroscopy (NIRS) signals and venous hemoglobin oxygen saturation (O2Hb%) and venous oxygen concentration (CvO2). Methods Gastrocnemius muscles (GS) in six dogs were surgically isolated and pump perfused. NIRS signals were recorded, and venous blood samples were collected at constant flow rates (control flow, high flow, and low flow) at rest as well as during electrically stimulated tetanic muscle contractions at rates of one contraction per 2 s (1/2 s) and two contractions per 3 s (2/3 s). Similar data were also collected at three different inspired O2 percentages (12%, 21%, and 100%) with constant blood flow. Results Complete data from five animals were analyzed; all data from one animal were deleted because of erratic oxy-NIRS signals. Venous O2Hb% ranged from 7.6% to 97.5% across the various experimental conditions. After the NIRS signals were normalized to the physiological range, a high linear correlation was seen between the deoxygenated heme signal (HHbMb%) and the venous O2Hb% (R = 0.92 ± 0.05), between the oxygenated heme signal (HbMbO2%) and the venous O2Hb% (R = 0.92 ± 0.03), between the HHbMb% and the CvO2 (R = 0.89 ± 0.06), and between the HbMbO2% and the CvO2 (R = 0.90 ± 0.05). The overall relationships between HHbMb%, HbMbO2%, and venous O2Hb% as well as between HHbMb%, HbMbO2%, and CvO2 were also linear and highly correlated with R values ranging from 0.81 to 0.90. Conclusion In this…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Invasive experiments, such as isolated hindlimb experiments with animal subjects13,14 or venous blood draw in humans performing exercise protocols,15 show good results.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [14]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Density and composition of mammalian muscle
Méndez, J., & Keys, A. (1960) · Metabolism · Cited by 802
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
Cited by
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
Okushima, D., Poole, D. C., Barstow, T. J., Rossiter, H. B., Kondo, N., Bowen, T. S., Amano, T., & Koga, S. (2016) · Physiological Reports · doi:10.14814/phy2.13065 · Cited by 58
“…from direct measurements during muscle contractions suggest that deoxy [Hb+Mb] is an index of regional fractional O2 extraction in the face of presiding blood flow (i.e., microvascular O2 partial pressure (Koga et al. 2012)) and femoral venous O2 saturation (Vogiatzis et al. 2015; Sun et al. 2016).”
BackgroundMulti‐vital on‐skin optoelectronic biosensor for assessing regional tissue hemodynamics
Xin, M., Yu, T., Jiang, Y., Tao, R., Li, J., Ran, F., Zhu, T., Huang, J., Zhang, J., Zhang, J., et al. (2022) · SmartMat · doi:10.1002/smm2.1157 · Cited by 32
“Monitoring the oxygen consumption process of human muscle tissue is key to starting the clinical PAD monitoring and diagnosis experiment.(40) The device can accurately judge the time at which the muscle lactate threshold is reached, which could be of great significance to the field of sports medicine and health rehabi…”
BackgroundGojda, J., Waldauf, P., Hrušková, N., Blahutová, B., Krajčová, A., Urban, T., Tůma, P., Řasová, K., & Duška, F. (2019) · PLoS ONE · doi:10.1371/journal.pone.0200228 · Cited by 31
Tucker, W. J., Rosenberry, R., Trojacek, D., Chamseddine, H. H., Arena-Marshall, C. A., Zhu, Y., Wang, J., Kellawan, J. M., Haykowsky, M. J., Tian, F., et al. (2019) · The Journal of Physiology · doi:10.1113/jp277580 · Cited by 29
“…1995; DeLorey et al. 2003, 2004; Grassi et al. 2003; Ferreira et al. 2005; Broxterman et al. 2014, 2015; Koga et al. 2014; Grassi & Quaresima, 2016; Sun et al. 2016; Barstow, 2019) – introduces exciting new possibilities for understanding the determinants of muscle oxygen utilization at the…”
BackgroundMethodResultInfluential
Metadata
- Authors
- SUN, Y., FERGUSON, B. S., ROGATZKI, M. J., MCDONALD, J. R., & GLADDEN, L. B.
- Affiliations
- University of Wisconsin–Platteville (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2016-10
- Volume
- 48
- Issue
- 10
- Pages
- 2013-2020
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2415320943
- Semantic Scholar
- 3450eb002540a0acfb4c3e4947e8295c1c13d9c2
- Cited by
- 16
- References
- 31
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 5 · 2022: 2 · 2021: 1 · 2019: 4 · 2016: 1
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- near-infrared spectroscopy, skeletal muscle oxygenation, gastrocnemius, muscle blood flow, fraction of inspired oxygen, tetanic contraction, canine model
- MeSH terms
- Animals, Dogs, Myoglobin, Oxygen, Oxyhemoglobins, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.