Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE: Accelerometers are increasingly being used to assess physical activity in large-scale surveys. Establishing whether key physical activity outcomes can be considered equivalent between three widely used accelerometer brands would be a significant step toward capitalizing on the increasing availability of accelerometry data for epidemiological research. METHODS: Twenty participants wore a GENEActiv, an Axivity AX3, and an ActiGraph GT9X on their nondominant wrist and were observed for 2 h in a simulated living space. Participants undertook a series of seated and upright light/active behaviors at their own pace. All accelerometer data were processed identically using open-source software (GGIR) to generate physical activity outcomes (including average dynamic acceleration (ACC) and time within intensity cut points). Data were analyzed using pairwise 95% equivalence tests (±10% equivalence zone), intraclass correlation coefficients (ICC) and limits of agreement. RESULTS: The GENEActiv and Axivity could be considered equivalent for ACC (ICC = 0.95, 95% confidence interval (CI), 0.87-0.98), but ACC measured by the ActiGraph was approximately 10% lower (GENEActiv/ActiGraph: ICC = 0.86; 95% CI, 0.56-0.95; Axivity/ActiGraph: ICC = 0.82; 95% CI, 0.50-0.94). For time spent within intensity cut points, all three accelerometers could be considered equivalent to each other for more than 85% of outcomes (ICC ≥0.69, lower 95% CI ≥0.36), with the GENEActiv and Axivity equivalent for 100% of outcomes (ICC ≥0.95, lower 95% CI ≥0.86). CONCLUSIONS: GENEActiv and Axivity data processed in GGIR are largely equivalent. If GENEActiv or Axivity is compared with the ActiGraph, time spent within intensity cut points has good agreement. These findings can be used to inform selection of appropriate outcomes if outputs from these accelerometer brands are compared.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [49]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250 · cited 2×
“[6,9,21–24]), but a notable exception is UK Biobank, where the Axivity was worn on the dominant wrist (4).”
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043 · cited 2×
“MVPA was calculated using an acceleration cut-point of 100 mg (13).”
BackgroundMethodEvolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968 · cited 1×
“Earlier accelerometers processed data into counts using proprietary algorithms (10); this complicated the interpretation and comparison of data from studies using different devices (11).”
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926 · cited 1×
“To facilitate transparent processing of these raw data, the generation and use of open-source resources is encouraged (16,17).”
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676 · cited 1×
“This included autocalibration using local gravity as a reference (19), detection of sustained abnormally high values, calculation of the average magnitude of dynamic acceleration (i.”
Mons, U., Muezzinler, A., Gellert, C., Schottker, B., Abnet, C. C., Bobak, M., de Groot, L., Freedman, N. D., Jansen, E., Kee, F., et al. (2015) · BMJ · doi:10.1136/bmj.h1551 · Cited by 526 · cited 1×
“smoking, overweight) for cardiovascular events, cardiovascular disease and mortality that have informed clinical and public health practice (1, 2).”
Evaluation of raw acceleration sedentary thresholds in children and adults
Hildebrand, M., Hansen, B. H., van Hees, V. T., & Ekelund, U. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12795 · Cited by 425 · cited 3×
“The inability to differentiate between postures using magnitude of acceleration alone has been previously reported (14,15) with use of further features from the acceleration signal recommended for classification of posture (e.”
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1×
“We selected ±10% of the mean as our proposed equivalence zone as in previous studies comparing activity monitors (31, 32).”
MethodWear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Self-citationChen, Y., Copeland, W. K., Vedanthan, R., Grant, E., Lee, J. E., Gu, D., Gupta, P. C., Ramadas, K., Inoue, M., Tsugane, S., et al. (2013) · BMJ · doi:10.1136/bmj.f5446 · Cited by 299
Utilization and Harmonization of Adult Accelerometry Data: Review and Expert Consensus
WIJNDAELE, K., WESTGATE, K., STEPHENS, S. K., BLAIR, S. N., BULL, F. C., CHASTIN, S. F. M., DUNSTAN, D. W., EKELUND, U., ESLIGER, D. W., FREEDSON, P. S., et al. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000661 · Cited by 297 · cited 1×
“Earlier accelerometers processed data into counts using proprietary algorithms (10); this complicated the interpretation and comparison of data from studies using different devices (11).”
Self-citationvan Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L., Pomeroy, J., Wareham, N. J., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022922 · Cited by 289 · cited 2×
“Critically, the GGIR accelerometer processing package used in this study (17, 18, 19) can be easily applied to large datasets and is available open-source, as is the function we created to convert Axivity raw files to a format that can be analysed in GGIR.”
da Silva, I. C., van Hees, V. T., Ramires, V. V., Knuth, A. G., Bielemann, R. M., Ekelund, U., Brage, S., & Hallal, P. C. (2014) · International Journal of Epidemiology · doi:10.1093/ije/dyu203 · Cited by 243 · cited 3×
“This elicited an average acceleration across the total period similar to the daily average acceleration observed in free-living individuals (6), strengthening the ecological validity of the results.”
Bakrania, K., Yates, T., Rowlands, A. V., Esliger, D. W., Bunnewell, S., Sanders, J., Davies, M., Khunti, K., & Edwardson, C. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0164045 · Cited by 165
Self-citationMenai, M., van Hees, V. T., Elbaz, A., Kivimaki, M., Singh-Manoux, A., & Sabia, S. (2017) · Scientific Reports · doi:10.1038/srep45772 · Cited by 159 · cited 1×
“The Pelotas Birth Cohort (6), the Melbourne Child Health Checkpoint (7), the Cork Children_s Lifestyle Study (8), and the British Whitehall II study (9) used the GENEActiv in approximately 10,000, 4000, 1000, and 3750 participants, respectively.”
Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts
Brønd, J. C., & Arvidsson, D. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00628.2015 · Cited by 146 · cited 1×
“These consistent differences we, and others, have observed may relate to technical differences between the brands (12, 20, 36); specifically it appears there is some onboard processing of the raw acceleration signal of the ActiGraph device, but details of this are proprietary (36, 37).”
BackgroundRaw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter?
ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000978 · Cited by 137 · cited 8×
“On the basis of our previous work comparing GGIR physical activity outputs from the GENEActiv and the ActiGraph (20), we anticipated that the SD of the differences between the log transformed outputs from the two accelerometers would be less than 0.”
InfluentialSelf-citationAssessing Sedentary Behavior with the GENEActiv: Introducing the Sedentary Sphere
ROWLANDS, A. V., OLDS, T. S., HILLSDON, M., PULSFORD, R., HURST, T. L., ESTON, R. G., GOMERSALL, S. R., JOHNSTON, K., & LANGFORD, J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000224 · Cited by 117
Self-citationPerformance of activity classification algorithms in free-living older adults
SASAKI, J. E., HICKEY, A. M., STAUDENMAYER, J. W., JOHN, D., KENT, J. A., & FREEDSON, P. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000844 · Cited by 112
Healthy obesity and objective physical activity
Bell, J. A., Hamer, M., van Hees, V. T., Singh-Manoux, A., Kivimäki, M., & Sabia, S. (2015) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.110924 · Cited by 90
Ramires, V. V., Wehrmeister, F. C., Wendt, A. T., Galliano, L. M., Ekelund, U., Brage, S., & Crochemore‐Silva, I. (2017) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0465-3 · Cited by 80
Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors
John, D., Sasaki, J. E., STAUDENMAYER, J. W., Mavilia, M. G., & Freedson, P. S. (2013) · Sensors · doi:10.3390/s131114754 · Cited by 77
Swerdlow, A. J., Jones, M. E., Schoemaker, M. J., Hemming, J., Thomas, D., Williamson, J., & Ashworth, A. (2011) · British Journal of Cancer · doi:10.1038/bjc.2011.337 · Cited by 76 · cited 1×
“For example, UK Biobank, a large-scale prospective epidemiological resource containing baseline phenotypic and genotypic data on 500,000 participants, has recently used the Axivity wrist-worn accelerometer in over 100,000 participants (4) and the Breakthrough Generation Study (5) has used the Axivity on 4,800 women to…”
Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors
Rowlands, A. V., Fraysse, F., Catt, M., Stiles, V. H., Stanley, R. M., Eston, R. G., & Olds, T. S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000394 · Cited by 60
Self-citationHorta, B. L., Schaan, B. D., Bielemann, R. M., Vianna, C. Á., Gigante, D. P., Barros, F. C., Ekelund, U., & Hallal, P. C. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.09.005 · Cited by 59
Challenges and Opportunities for Harmonizing Research Methodology: Raw Accelerometry
van Hees, V., Thaler-Kall, K., Wolf, K.-H., Brønd, J., Bonomi, A., Schulze, M., Vigl, M., Morseth, B., Hopstock, L. A., Gorzelniak, L., et al. (2016) · Methods of Information in Medicine · doi:10.3414/me15-05-0013 · Cited by 58 · cited 3×
“It is important to consider the accelerometer, processing, and analysis together when establishing whether outcomes can be considered equivalent or not, because each of these steps can affect the final outcome variable (16).”
Criterion Validity of Competing Accelerometry-Based Activity Monitoring Devices
KIM, Y., & WELK, G. J. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000691 · Cited by 41 · cited 1×
“We selected ±10% of the mean as our proposed equivalence zone as in previous studies comparing activity monitors (31, 32).”
Use of Accelerometry to Classify Activity Beneficial to Bone in Premenopausal Women
STILES, V. H., GRIEW, P. J., & ROWLANDS, A. V. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829ba765 · Cited by 36 · cited 2×
“In our previous studies comparing output from the GENEActiv and the ActiGraph, differences in output were consistent whether the monitors were taped together (12,28) or worn adjacent on the wrist (20).”
Self-citationMoving Forward with Backward Compatibility: Translating Wrist Accelerometer Data
ROWLANDS, A. V., CLIFF, D. P., FAIRCLOUGH, S. J., BODDY, L. M., OLDS, T. S., PARFITT, G., NOONAN, R. J., DOWNS, S. J., KNOWLES, Z. R., & BEETS, M. W. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001015 · Cited by 36
Self-citationLi, X., Kearney, P. M., Keane, E., Harrington, J. M., & Fitzgerald, T. (2017) · Journal of Epidemiology & Community Health · doi:10.1136/jech-2016-207691 · Cited by 30 · cited 2×
“The Pelotas Birth Cohort (6), the Melbourne Child Health Checkpoint (7), the Cork Children‟s Lifestyle Study (8), and the British Whitehall II study (9) used the GENEActiv in approximately 10,000, 4,000, 1,000 and 3,750 participants, respectively.”
Background(9394701), M. W., (9852083), S. C., (13690837), E. Y., (7401437), F. M., (13071603), L. G., (13309263), D. B., & (6285992), S. D. (2025) · Figshare · Cited by 13
Cited by
Migueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
“Further, GGIR is continually updated to include innovations developed by the software team and/or users expediting the application of novel analytics in research (Rowlands, Edwardson, et al., 2018; Rowlands, Mirkes, et al., 2018; van Hees et al., 2014, 2015, 2018).”
MethodSelf-citationEstimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
GWAS identifies 14 loci for device-measured physical activity and sleep duration
Doherty, A., Smith-Byrne, K., Ferreira, T., Holmes, M. V., Holmes, C., Pulit, S. L., & Lindgren, C. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07743-4 · Cited by 408
Ancillao, A., Tedesco, S., Barton, J., & O’Flynn, B. (2018) · Sensors · doi:10.3390/s18082564 · Cited by 243
Ramakrishnan, R., Doherty, A., Smith-Byrne, K., Rahimi, K., Bennett, D., Woodward, M., Walmsley, R., & Dwyer, T. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003487 · Cited by 183
Metadata
- Authors
- ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L.
- Affiliations
- University of Leicester (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-02
- Volume
- 50
- Issue
- 2
- Pages
- 257-265
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2763127012
- Semantic Scholar
- c578c1bec7d8dd5a50d0118464d02d7a7a63d3eb
- Cited by
- 187
- References
- 34
- Citations by year
- 2026: 16 · 2025: 17 · 2024: 25 · 2023: 15 · 2022: 26 · 2021: 32 · 2020: 27 · 2019: 15 · 2018: 13
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- green
- journals.lww.com
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Leicester Research Archive (University of Leicester) (acceptedVersion, other-oa)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Figshare (submittedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute for Health and Care Research
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- accelerometer, physical activity measurement, GENEActiv, ActiGraph GT9X, wrist-worn accelerometry, equivalence testing, limits of agreement
- MeSH terms
- Acceleration, Adolescent, Adult, Female, Humans, Male, Software, Exercise, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.