Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE: Accelerometers are increasingly being used to assess physical activity in large-scale surveys. Establishing whether key physical activity outcomes can be considered equivalent between three widely used accelerometer brands would be a significant step toward capitalizing on the increasing availability of accelerometry data for epidemiological research. METHODS: Twenty participants wore a GENEActiv, an Axivity AX3, and an ActiGraph GT9X on their nondominant wrist and were observed for 2 h in a simulated living space. Participants undertook a series of seated and upright light/active behaviors at their own pace. All accelerometer data were processed identically using open-source software (GGIR) to generate physical activity outcomes (including average dynamic acceleration (ACC) and time within intensity cut points). Data were analyzed using pairwise 95% equivalence tests (±10% equivalence zone), intraclass correlation coefficients (ICC) and limits of agreement. RESULTS: The GENEActiv and Axivity could be considered equivalent for ACC (ICC = 0.95, 95% confidence interval (CI), 0.87-0.98), but ACC measured by the ActiGraph was approximately 10% lower (GENEActiv/ActiGraph: ICC = 0.86; 95% CI, 0.56-0.95; Axivity/ActiGraph: ICC = 0.82; 95% CI, 0.50-0.94). For time spent within intensity cut points, all three accelerometers could be considered equivalent to each other for more than 85% of outcomes (ICC ≥0.69, lower 95% CI ≥0.36), with the GENEActiv and Axivity equivalent for 100% of outcomes (ICC ≥0.95, lower 95% CI ≥0.86). CONCLUSIONS: GENEActiv and Axivity data processed in GGIR are largely equivalent. If GENEActiv or Axivity is compared with the ActiGraph, time spent within intensity cut points has good agreement. These findings can be used to inform selection of appropriate outcomes if outputs from these accelerometer brands are compared.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [49]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250 · cited 2×
“[6,9,21–24]), but a notable exception is UK Biobank, where the Axivity was worn on the dominant wrist (4).”
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043 · cited 2×
“MVPA was calculated using an acceleration cut-point of 100 mg (13).”
BackgroundMethodEvolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968 · cited 1×
“Earlier accelerometers processed data into counts using proprietary algorithms (10); this complicated the interpretation and comparison of data from studies using different devices (11).”
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926 · cited 1×
“To facilitate transparent processing of these raw data, the generation and use of open-source resources is encouraged (16,17).”
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676 · cited 1×
“This included autocalibration using local gravity as a reference (19), detection of sustained abnormally high values, calculation of the average magnitude of dynamic acceleration (i.”
Mons, U., Muezzinler, A., Gellert, C., Schottker, B., Abnet, C. C., Bobak, M., de Groot, L., Freedman, N. D., Jansen, E., Kee, F., et al. (2015) · BMJ · doi:10.1136/bmj.h1551 · Cited by 526 · cited 1×
“smoking, overweight) for cardiovascular events, cardiovascular disease and mortality that have informed clinical and public health practice (1, 2).”
Evaluation of raw acceleration sedentary thresholds in children and adults
Hildebrand, M., Hansen, B. H., van Hees, V. T., & Ekelund, U. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12795 · Cited by 425 · cited 3×
“The inability to differentiate between postures using magnitude of acceleration alone has been previously reported (14,15) with use of further features from the acceleration signal recommended for classification of posture (e.”
Cited by
Items 101–195 of 195
Validation of physical activity levels from shank-placed Axivity AX6 accelerometers in older adults
Gafoor, F., Ruder, M. C., & Kobsar, D. (2024) · PLoS ONE · doi:10.1371/journal.pone.0290912 · Cited by 6
Measuring 24‐h use of time in people with a diabetes‐related foot ulcer: A feasibility study
Murphy, A., Graham, K., Olds, T., Loughry, C., Fraysse, F., Dumuid, D., Stanford, T., & Matricciani, L. (2024) · Journal of Foot and Ankle Research · doi:10.1002/jfa2.12045 · Cited by 7
“Concurrent validity has been demonstrated for measures of PA, sleep and sedentary time against other devices, with intraclass correlation coefficient values ranging from 0.82 to 0.95 across multiple time ‐ use domains [38].”
InfluentialSchütz, N., Saner, H. E., Botros, A., Buluschek, P., Urwyler, P., Müri, R. M., & Nef, T. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2020.566595 · Cited by 7
“with the widely used and validated (30) Axivity AX3 (Axivity”
MethodFenton, S. A. M., O’Brien, C. M., Kitas, G. D., Duda, J. L., Zanten, J. V., & Metsios, G. S. (2022) · Rheumatology Advances in Practice · doi:10.1093/rap/rkac097 · Cited by 6
Buchan, D. S., & Baker, J. S. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20032293 · Cited by 7
Comparing Five Generations of ActiGraph Devices Using an Orbital Shaker
LaMunion, S. R., NGUYEN, J., Brychta, R. J., Troiano, R. P., Friedl, K. E., & Chen, K. Y. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003652 · Cited by 5
“Thus, deploying devices of a single generation is often desirable because differences between device generations (1 – 6) and manufacturers (7 – 10) have been identified.”
Assessment of physical activity patterns in patients with rheumatoid arthritis using the UK Biobank
Hamy, V., Creagh, A. P., & Garcia‐Gancedo, L. (2025) · PLoS ONE · doi:10.1371/journal.pone.0319908 · Cited by 5
Twenty‐four‐hour physical behaviour profiles across type 2 diabetes mellitus subtypes
Henson, J. J., Tziannou, A., Rowlands, A. V., Edwardson, C. L., Hall, A. P., Davies, M. J., & Yates, T. E. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15437 · Cited by 6
Self-citationBoddy, L. M., Noonan, R. J., Rowlands, A. V., Hurter, L., Knowles, Z. R., & Fairclough, S. J. (2019) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2019.02.001 · Cited by 6
Self-citationRuiz, M. F., Hoang, L. C., & Muttoni, A. (2022) · Hormigón y Acero · doi:10.33586/hya.2022.3086 · Cited by 7
Wilson, S. L., Crosley‐Lyons, R., Junk, J., Hasanaj, K., Larouche, M. L., Hollingshead, K. E., Gu, H., Whisner, C. M., Sears, D. D., & Buman, M. P. (2023) · JMIR Research Protocols · doi:10.2196/45133 · Cited by 5
Innovations in Skeleton-Based Movement Recognition Bridging AI and Human Kinetics
Singh, K., Visuwasam, L. M. M., Rajasekaran, G. R., Regin, R., Rajest, S. S., & Shynu, T. (2024) · Advances in computational intelligence and robotics book series · doi:10.4018/979-8-3693-1355-8.ch008 · Cited by 5
Vyhlídal, T., Dygrýn, J., Hrubá, J., & Chmelík, F. (2023) · Scientific Reports · doi:10.1038/s41598-023-34689-5 · Cited by 4
Sarvestan, J., Baker, K. F., & Din, S. D. (2024) · Bioengineering · doi:10.3390/bioengineering12010018 · Cited by 4
Rockette‐Wagner, B., & Aggarwal, R. (2024) · Rheumatology · doi:10.1093/rheumatology/keae004 · Cited by 5
Clevenger, K. A., McKee, K. L., Elwood, R. E., Pfeiffer, K. A., & Montoye, A. H. K. (2025) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2025.2473904 · Cited by 4
“For example, mean acceleration represents average activity intensity across the wear period and has been shown to be comparable across device brands (Buchan, 2022; Rowlands et al., 2017).”
Elhakeem, A., Gregson, C. L., Tobias, J. H., & Lawlor, D. A. (2020) · Annals of Human Biology · doi:10.1080/03014460.2019.1707284 · Cited by 4
“The Axivity AX3 accelerometers were shown to have equivalent acceleration profiles to Actigraph devices when worn at the same locations (Rowlands et al. 2018).”
MethodCoyle-Asbil, H. J., Habegger, J., Oliver, M. L., & Vallis, L. A. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3150972 · Cited by 4
Tommasini, F., Marques-Vidal, P. M., Kayser, B., Tasheva, P., Paraschiv-Ionescu, A., & Méan, M. (2022) · Swiss Medical Weekly · doi:10.57187/smw.2022.40012 · Cited by 4
Vindiš, J., Pelclová, J., Jašková, P., & Hron, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-09645-0 · Cited by 4
“Intensity-specific behaviors (SB, LPA, MVPA) were categorized using the GGIR package 18 in R software (version 4.4.0), applying Fraysse’s cut points for the Euclidian Norm Minus One metric 19,20 .”
InfluentialHayes, G., Dowd, K., MacDonncha, C., & Donnely, A. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2021-0023 · Cited by 4
Habitual Physical Activity of People with or at Risk of Diabetes-Related Foot Complications
Perrin, B., Diacogiorgis, D., Sullivan, C. J., Gerrard, J. M., Skinner, I., Skinner, T. C., Nawaratne, R., Alahakoon, D., & Kingsley, M. (2023) · Sensors · doi:10.3390/s23135822 · Cited by 3
“01 g (10 mg), if they had fewer than 3 days of valid wear (defined as >16 h per day), or if wear data were not present for each 15 min period of the 24 h cycle [26,27].”
BackgroundSuorsa, K., Lindstedt, M., Rasmussen, C. L., Leskinen, T., Pasanen, J., Rovio, S., Heinonen, O. J., Viikari, J. S. A., Rönnemaa, T., Niinikoski, H., et al. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14751 · Cited by 3
Clevenger, K. A., McNarry, M. A., Mackintosh, K. A., Pfeiffer, K. A., Nelson, B. A., Bock, J. M., Imboden, M. T., Kaminsky, L. A., & Montoye, A. H. K. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0013 · Cited by 3
McDevitt, B., Connolly, J., Duddy, D., Doherty, R., & Condell, J. V. (2022) · Irish Signals and Systems Conference · doi:10.1109/issc55427.2022.9826199 · Cited by 4
Shivgulam, M. E., & O'Brien, M. W. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0021 · Cited by 4
Santos, I. S., Echevarria, P., Tovo‐Rodrigues, L., Matijasevich, A., Domingues, M. R., & Hallal, P. C. (2024) · Sleep Medicine X · doi:10.1016/j.sleepx.2024.100105 · Cited by 3
“Comparisons between the raw data of the two devices are available elsewhere [20,21].”
BackgroundVideo-Recorded Direct Observation: A Step Forward for Physical Activity Measurement
Keadle, S. K. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001586 · Cited by 3
“In recent years, measurement scientists have made great progress by obtaining and processing output in acceleration units (mg), which makes output across devices comparable (5).”
BackgroundStewart, M. T., Nezich, T., Lee, J. M., Hasson, R. E., & Colabianchi, N. (2021) · JMIR mhealth and uhealth · doi:10.2196/17581 · Cited by 3
“Data were analyzed using a 10-minute bout metric in which at least 80% of the bout needed to be at or above the MVPA threshold.”
BackgroundMethodInfluentialMiddle Aged Women and their Physical Activity Leisure Selves
Elliott, A., Turner, A. N., & Volante, M. (2025) · International Journal of the Sociology of Leisure · doi:10.1007/s41978-025-00180-w · Cited by 2
“Studies that employ objective methods such as using accelerometers to measure participation (Rowlands et al., 2018) might be missing a key facet.”
Confortin, S. C., Rocha, P. R. H., da Silva, B. G. C., Menezes, A. M. B., Horta, B. L., Gonçalves, H., Bettiol, H., Barbieri, M. A., Saraiva, M. D. C. P., Alves, M. T. S. S. D. B. E., et al. (2022) · Revista Brasileira de Epidemiologia · doi:10.1590/1980-549720220024 · Cited by 3
Paediatric cancer survivors: lean mass attenuates negative impact of watching television on bone
Mármol-Pérez, A., Ubago‐Guisado, E., Llorente‐Cantarero, F. J., Cadenas‐Sánchez, C., Rodríguez-Solana, A., Gil-Cosano, J. J., Pascual-Gázquez, J. F., Ruiz, J. R., & Gracia‐Marco, L. (2024) · Pediatric Research · doi:10.1038/s41390-024-03714-2 · Cited by 2
Chu, M., Hu, C., Zhu, L., Lyu, J., Wang, F., & Tao, X. (2025) · BMC Nephrology · doi:10.1186/s12882-025-04100-8 · Cited by 2
Torres-Carballo, M., Galmes-Panades, A. M., Arias-Fernández, M., Huguet-Torres, A., Abbate, M., Fresneda, S., Sánchez-Rodríguez, C., Yáñez, A. M., & Bennasar‐Veny, M. (2025) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2025.1579962 · Cited by 2
Výzkum orientovaný na pohybovou aktivitu: metodologické ukotvení
Cuberek, R. (2019) · doi:10.5507/ftk.19.24455976 · Cited by 4
Development and Calibration of a PATCH Device for Monitoring Children’s Heart Rate and Acceleration
Armstrong, B., Weaver, R. G., McAninch, J., Smith, M. T., Parker, H., Lane, A. D., Wang, Y., PATE, R. R., Rahman, M., Matolak, D. W., et al. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003404 · Cited by 2
“For acceleration, based on previous research and best practice (23,46), bounds were set at 10% of the mean value of the Actiheart.”
BackgroundMethodInfluentialStrehli, I., Burns, R. D., Bai, Y., Ziegenfuss, D. H., Block, M. E., & Brusseau, T. A. (2022) · Research Square · doi:10.21203/rs.3.rs-1522812/v1 · Cited by 2
Putris, J., Okuyan, A. A., Balkanas, M., Söylemezoğlu, A. E., Serdengeçti, N., Kadak, T., Tarakçıoğlu, M. C., & Töreyin, H. (2023) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi58575.2023.10313419 · Cited by 1
“The equivalence and agreement between the two watches in measuring acceleration is demonstrated in [15], with an intraclass correlation coefficient of 0.95 (95% confidence interval: 0.87-0.98).”
BackgroundInfluentialBrailey, G., Metcalf, B. S., Price, L., Cumming, S. P., Rowlands, A. V., Olds, T., Simm, P. J., Wake, M. A., & Stiles, V. H. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12122 · Cited by 1
“…assessing free ‐ living, bone ‐ relevant PA and use open ‐ source software that permits the transparent and reproducible analysis of raw accelerometry data (Migueles et al., 2019), which will enhance the ability to quantify dose ‐ response associations in the future (Rowlands et al., 2018).”
BackgroundSelf-citationVechia, T. G. D., Flores, T. R., Menezes, A. M. B., Wehrmeister, F. C., Gonçalves, H., & da Silva, B. G. C. (2025) · Ciência & Saúde Coletiva · doi:10.1590/1413-81232025309.00132024 · Cited by 2
Duhamahoro, J., Hibbing, P. R., Lamoureux, N. R., Berg, E. J., & Welk, G. J. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2025-0024 · Cited by 1
Hasanaj, K., Leonard, K. S., Sears, D. D., Yu, F., Petrov, M. E. R., Keadle, S. K., & Buman, M. P. (2026) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-026-00096-0 · Cited by 1
“Data files were excluded if the post-calibration error was > 0.01 g (10 mg), fewer than 1 day of valid wear [48, 52], or wear data were not present for each 15-min period of the 24-h cycle.”
InfluentialEffects of Axivity 3.0-based management model on pregnant women with gestational diabetes mellitus
Cai, F., Wu, Y., Liu, B., & Xu, M. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1722822 · Cited by 1
Li, R., Lei, F., Liu, B., Lin, L., Huang, X., Zhang, X., Liu, W., Sun, T., Cao, Y., Wu, Q., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.043217 · Cited by 1
Lošťák, J., Gába, A., Dygrýn, J., BALÁŽ, Ľ., Štefelová, N., & Gallo, J. (2022) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2022/001 · Cited by 1
Application of Accelerometer to Monitor Students’ Exercise Load in 50 m Round Trip
Li, H., & Xu, M. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/3142677 · Cited by 1
“Obviously, when the information gain entropy get larger, this means that using this attribute as the splitting attribute can distinguish different samples well [25].”
BackgroundRetractedSalway, R., Augustin, N. H., & Armstrong, M. E. G. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20146401 · Cited by 1
“The curve was highest between 3 and 100 mg (approximately sedentary to light intensity PA [32]), indicating an area of higher risk, and lowest above 250 mg (approximately MVPA [26]), indicating an area of lower risk.”
BackgroundMaylor, B. D., Rowlands, A. V., Daley, A., Sanders, J. P., Yates, T., & Edwardson, C. L. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0056 · Cited by 2
Self-citationKinuthia, S. K., Stratton, G., Wachira, L.-J. M., Okoth, V., Owino, G., Ochola, S., Kiplamai, F., Onywera, V. O., & Swindell, N. J. (2025) · PLoS ONE · doi:10.1371/journal.pone.0329173 · Cited by 1
A Novel Mixed Methods Approach to Assess Children’s Sedentary Behaviors
Hurter, L., Cooper-Ryan, A. M., Knowles, Z. R., Porcellato, L. A., Fairclough, S. J., & Boddy, L. M. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0040 · Cited by 1
Measuring the relationship between sleep, physical activity and cognitionPreprint
Swirski, M., Shaikh, N., Chinner, A., Gaaikema, E., & Coulthard, E. J. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/599092 · Cited by 1
Galmes-Panades, A. M., Konieczna, J., Varela-Mato, V., Abete, I., Babió, N., Fiol, M., Fernández, J. A. D. P., Casas, R. M., Olbeyra, R. P., Ruiz‐Canela, M., et al. (2020) · Research Square · doi:10.21203/rs.3.rs-44115/v1 · Cited by 1
Spanish Costaleros’ Physical Activity and Their Quality of Life
Ubago-Jiménez, J. L., Ortega, F. Z., Puertas-Molero, P., & González-Valero, G. (2020) · Sensors · doi:10.3390/s20195641
Sedentary time across the transition to retirement and after an activity tracker intervention
Suorsa, K. (2021) · UTUPub (University of Turku) · Cited by 1
Coyle-Asbil, H. J. (2021) · The Atrium (University of Guelph) · Cited by 1
Physical education pedagogies and physical activity in primary school children
Crotti, M. (2021) · Liverpool John Moores University
Weather variation in objectively measured physical activity: results of four Brazilian cohortsPreprint
Martins, R. C., Blumenberg, C., Wendt, A. T., Müller, W. D. A., Santos, I. S., Matijasevich, A., Domingues, M. R., Bertoldi, A. D., Gonçalves, H., Wehrmeister, F. C., et al. (2023) · medRxiv · doi:10.1101/2023.03.02.23285008
“1 According to Rowlands et al. (2018),(34) there is a good agreement between raw data 2 from both devices if worn in the non-dominant wrist (intraclass correlation coefficient 3 = 0.86; 95%CI: 0.56 – 0.95).”
BackgroundInfluentialSOARES, A. C., Pancoti, B. M., & de Oliveira, A. J. (2022) · journal of physical education · doi:10.4025/jphyseduc.v33i1.3344 · Cited by 1
Vindiš, J., Pelclová, J., Škvařilová, M., Aiglová, R., Nohelová, D., Flašík, J., Keprt, P., & Táborský, M. (2023) · Cor et Vasa · doi:10.33678/cor.2023.038
Sayyah, M., Clemes, S. A., Maylor, B. D., Edwardson, C. L., Sherry, A. P., Ruettger, K. B., Chen, Y., Varela-Mato, V., Guest, A. J., King, J. A., et al. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0027
Self-citationStewart, M. (2023) · Deep Blue (University of Michigan) · doi:10.7302/8478 · Cited by 1
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047105
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047099
Cornu, Q. L., Chen, M., van Hees, V. T., Léger, D., Fayossé, A., Yerramalla, M. S., & Sabia, S. (2024) · Figshare · doi:10.6084/m9.figshare.26552227
Galmes-Panades, A. M., Konieczna, J., Varela-Mato, V., Abete, I., Babió, N., Fiol, M., Antonio de Paz, J., Casas, R., Olbeyra, R. P., Ruiz‐Canela, M., et al. (2021) · Figshare · doi:10.6084/m9.figshare.13524902
Suorsa, K., Leskinen, T., Pasanen, J., Pulakka, A., Myllyntausta, S., Pentti, J., Chastin, S., Vahtera, J., & Stenholm, S. (2022) · Figshare · doi:10.6084/m9.figshare.21130087
Yerramalla, M. S., McGregor, D. E., van Hees, V. T., Fayossé, A., Dugravot, A., Tabák, Á. G., Chen, M., Chastin, S. F. M., & Sabia, S. (2021) · Figshare · doi:10.6084/m9.figshare.14955977
Yerramalla, M. S., McGregor, D. E., van Hees, V. T., Fayossé, A., Dugravot, A., Tabák, Á. G., Chen, M., Chastin, S. F. M., & Sabia, S. (2021) · Figshare · doi:10.6084/m9.figshare.14955980
Yerramalla, M. S., McGregor, D. E., van Hees, V. T., Fayossé, A., Dugravot, A., Tabák, Á. G., Chen, M., Chastin, S. F. M., & Sabia, S. (2021) · Figshare · doi:10.6084/m9.figshare.14955983
Suorsa, K., Leskinen, T., Pasanen, J., Pulakka, A., Myllyntausta, S., Pentti, J., Chastin, S., Vahtera, J., & Stenholm, S. (2022) · Figshare · doi:10.6084/m9.figshare.21130086
Schwendinger, F., Wagner, J., Infanger, D., Schmidt-Trucksäss, A., & Knaier, R. (2021) · Figshare · doi:10.6084/m9.figshare.17010147
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047108
Galmes-Panades, A. M., Konieczna, J., Varela-Mato, V., Abete, I., Babió, N., Fiol, M., Antonio de Paz, J., Casas, R., Olbeyra, R. P., Ruiz‐Canela, M., et al. (2021) · Figshare · doi:10.6084/m9.figshare.13524905
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047102
Suorsa, K., Leskinen, T., Pasanen, J., Pulakka, A., Myllyntausta, S., Pentti, J., Chastin, S., Vahtera, J., & Stenholm, S. (2022) · Figshare · doi:10.6084/m9.figshare.21130088
Armitage, L. C., Chi, Y., Santos, M., Lawson, B. K., Areia, C., Velardo, C., Watkinson, P., Tarassenko, L., Costa, M. L., & Farmer, A. J. (2020) · Figshare · doi:10.6084/m9.figshare.12361232
Rodríguez-Solana, A. (2024) · Institutional Repository of the University of Granada (University of Granada)
Rameshk, H. (2019) · NVA (Nasjonalt vitenarkiv)
Hayes, G. (2021) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/7046
Mâsse, L. C., González, O. D.-J., Sauve, K., Tugault-Lafleur, C. N., LeMare, L., & Naylor, P. (2026) · BMC Public Health · doi:10.1186/s12889-025-26112-7
“Acceleration values and cut-points from this device have been shown to be equivalent to those of the Axivity AX3 device used in this study [43].”
Vylder, F. D., Cardon, G., Compernolle, S., Goossens, L., Maenhout, L., & Dyck, D. V. (2026) · Appetite · doi:10.1016/j.appet.2026.108458 · Cited by 1
O’Rourke, B. (2021) · TSpace (University of Toronto)
Rodríguez-Solana, A., Gracia‐Marco, L., Migueles, J. H., Mármol-Pérez, A., Cadenas‐Sánchez, C., Gil-Cosano, J. J., Llorente‐Cantarero, F. J., & Ubago‐Guisado, E. (2026) · Heliyon · doi:10.1016/j.heliyon.2026.e44602
Objective functional assessment in orthopedics: The emerging role of wearable technologies
Wu, J. A., Kutzer, K. M., Shenoy, D. A., Yanez, G., Zirbes, C. F., Shah, S. N., Jing, C., Choudhury, A., Song, J., Mai, E., et al. (2026) · World Journal of Orthopedics · doi:10.5312/wjo.v17.i3.114693
Duhamahoro, J., Weaver, R. G., Finnegan, O., Zhong, Z., Nelakuditi, S., Berg, E. J., & Welk, G. J. (2026) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2026.2649842
Medina, Y. N., de León, S. C., Barreiro-Bautista, M., Dávila‐Batista, V., Fabelo, H. A., Pavlovic, S., Delgado, Y. G., Jiménez, J. E., López-López, S., Wägner, A. M., et al. (2026) · Journal of Nutrition and Metabolism · doi:10.1155/jnme/1016106
Alexiuk, J. (2026) · Mspace (University of Manitoba)
Health-related quality of life in young pediatric cancer survivors: The role of sarcopenia
Mármol-Pérez, A., Ubago‐Guisado, E., Cadenas‐Sánchez, C., Rodríguez-Solana, A., Llorente‐Cantarero, F. J., Pascual-Gázquez, J. F., Moreira‐Gonçalves, D., Mota, J., Ness, K. K., Ruiz, J. R., et al. (2026) · Supportive Care in Cancer · doi:10.1007/s00520-026-10888-4
“We considered a day valid when: 1) the accelerometer registered at least 23 h/day and 2) survivors wore the accelerometers at least 16 h/day since in this study the accelerometers were worn at both day and night [19].”
Nafría, M., Chaplin, A., Prohens, L., Morey, M., Estelrich, A., Romaguera, D., & Sesé, A. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1764935
Goldney, J., Rowlands, A. V., Hamza, M., Hall, A. P., Misra, S., Wilmot, E. G., Edwardson, C. L., Khunti, K., Yates, T. E., Daynes, E., et al. (2026) · Metabologia · doi:10.1007/s44357-026-00007-5
“GENEActiv and Axivity AX3 devices are considered largely equivalent regarding estimating physical activity, with high correlation between measured outcomes [18].”
Self-citationTan, T. C., Zheng, J., Chen, T., Liu, Y., Luo, Y., Yang, Y., & Huang, T. (2026) · PeerJ · doi:10.7717/peerj.21490
“The Axivity AX3 has demonstrated excellent agreement with other research-grade wrist-worn accelerometers for average acceleration (ICC = 0.95, 95% CI [0.87–0.98]) ( Rowlands et al., 2018 ).”
InfluentialActivity Metrics from the ActiGraph GT9X Link and ActiGraph LEAP Using an Open-Source R Package
Suarez, J. R., Banarjee, C., Lafontant, K., Xie, R., & Thiamwong, L. (2026) · Research in Health and Medicine · doi:10.53520/rhm2026.104225
Harkin, A. E., Cawley, M., Morrow, E., Kurti, S. P., & Hargens, T. A. (2026) · Journal of American College Health · doi:10.1080/07448481.2026.2741615
Rådman, L., Zetterlund, J., Wågert, P. V. H., & Henriksson, A. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-125120
Metadata
- Authors
- ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L.
- Affiliations
- University of Leicester (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-02
- Volume
- 50
- Issue
- 2
- Pages
- 257-265
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2763127012
- Semantic Scholar
- c578c1bec7d8dd5a50d0118464d02d7a7a63d3eb
- Cited by
- 187
- References
- 34
- Citations by year
- 2026: 16 · 2025: 17 · 2024: 25 · 2023: 15 · 2022: 26 · 2021: 32 · 2020: 27 · 2019: 15 · 2018: 13
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- green
- journals.lww.com
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Leicester Research Archive (University of Leicester) (acceptedVersion, other-oa)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Figshare (submittedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute for Health and Care Research
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- accelerometer, physical activity measurement, GENEActiv, ActiGraph GT9X, wrist-worn accelerometry, equivalence testing, limits of agreement
- MeSH terms
- Acceleration, Adolescent, Adult, Female, Humans, Male, Software, Exercise, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.