Gait Speed and Step-Count Monitor Accuracy in Community-Dwelling Older Adults
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Accurate assessment of physical activity (PA) is necessary to identify the sedentary older individual who is in need of activity intervention. Activity monitors are quite popular, although it has been suggested that they are less accurate at slow gait speeds. PURPOSE: To examine the accuracy of the three activity monitors in older individuals who walk at various gait speeds. METHODS: Participants were 34 community-dwelling older men and women (mean age 79.2) who were asked to simultaneously wear three activity monitors: the Yamax DigiWalker (DW) pedometer (hip), the Actigraph (AG) accelerometer (hip), and the StepWatch activity monitor (SAM) (ankle). Monitor accuracy was evaluated against observed steps taken during a 100-step walking test. Percent error of the monitors was calculated as [(monitor steps - observed steps)/observed steps] x 100. Participants were categorized into three groups (< 0.80, 0.80-1.0, > 1.0 m x s(-1)) according to gait speed, which was determined by a timed 4-m walk. RESULTS: Overall, the DW and AG failed to detect 16% and 7% of observed steps, respectively, and the SAM overestimated by 5.5%. When stratified by gait speed, all three monitors faired well at the gait speeds > 1.0 m x s(-1). For gait speeds between 0.80 and 1.0 m x s(-1), the SAM overestimated steps by 6.6%, and the AG and DW underestimated steps by 5.7% and 12.7%, respectively. However, at gait speeds < 0.80 m x s(-1), the AG and DW performed poorly, underestimating steps by 19.1% and 31.2%, whereas the SAM performed better, having overestimated steps by 6.5%. CONCLUSIONS: All three objective activity monitors performed well at moderate and higher walking speeds, but at decreased gait speeds, the SAM seemed to be the most accurate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical performance measures in the clinical setting
Studenski, S., Perera, S., Wallace, D., Chandler, J. M., Duncan, P. W., Rooney, E., Fox, M., & Guralnik, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51104.x · Cited by 1,218
Cesari, M., Kritchevsky, S. B., Penninx, B. W. H. J., Nicklas, B. J., Simonsick, E. M., Newman, A. B., Tylavsky, F. A., Brach, J. S., Satterfield, S., Bauer, D. C., et al. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53501.x · Cited by 1,192
Self-citationValidity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
BLAIR, S. N., & BRODNEY, S. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199911001-00025 · Cited by 704 · cited 1×
“R egular physical activity levels can prolong health by offsetting the development of chronic disease and conditions, which can, in turn, preserve the quality of life in older individuals (5,6).”
BackgroundAccuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360 · cited 3×
“Unfortunately, activity monitors may not be accurate when assessing physical activity levels in individuals who walk slowly (19,20) and/or have gait deviations, both of which are common problems in older adults.”
BackgroundMethodSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295 · cited 1×
“A BMI of 32 kgIm was chosen because previous research has suggested that higher levels of BMI may influence the accuracy of activity monitors worn on the hip (9,32,34).”
MethodMeasurement of daily walking distance-questionnaire versus pedometer
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200005000-00021 · Cited by 260
Foster, R. C., Lanningham-Foster, L. M., Manohar, C., McCrady, S. K., Nysse, L. J., Kaufman, K. R., Padgett, D. J., & Levine, J. A. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2005.07.006 · Cited by 187 · cited 1×
“(13) also have examined the accuracy of the SAM, Accusplit pedometer, and the Omron piezoelectric pedometer in a younger population under controlled conditions.”
Method
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“The StepWatch showed better step counting at slow treadmill walking speed [77], but overestimated the steps during a 24 hour monitoring [78].”
MethodStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“The majority of articles compared activity monitor determined energy expenditure with DLW [73, 77, 80, 96, 105, 274, 275, 277, 278, 280, 281, 285, 292, 293, 295, 296, 300, 303–305, 311, 313, 317, 323], while activity monitor determined steps [119, 271, 283, 287, 289, 298, 299, 306, 307, 314, 315, 318], distance travel…”
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Evenson, K., Buchner, D., & Morland, K. (2011) · Preventing Chronic Disease · doi:10.5888/pcd9.110109 · Cited by 267
Metadata
- Authors
- STORTI, K. L., PETTEE, K. K., BRACH, J. S., TALKOWSKI, J. B., RICHARDSON, C. R., & KRISKA, A. M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2008-01
- Volume
- 40
- Issue
- 1
- Pages
- 59-64
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2042502570
- Cited by
- 155
- References
- 9
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.