Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
Abstract
PURPOSE: The purpose of this study was to examine the effects of BMI, waist circumference, and pedometer tilt on the accuracy of a spring-levered pedometer (Yamax Digiwalker SW-200 (SW)) and a piezo-electric pedometer (New Lifestyles NL-2000 (NL)) during treadmill walking and over a 24-h period in overweight and obese adults. METHODS: Forty participants (40 +/- 13.0 yr, 32.6 +/- 4.8 kg.m) walked on a treadmill at various speeds (54, 67, 80, 94, and 107 m.min) for 3-min stages. Simultaneously, an investigator determined actual steps by a hand counter. For all walking trials the SW and NL were positioned on the right and left waistband, respectively. Height, weight, pedometer tilt angle and circumference measures of the hip and waist were also measured. Thirty-six participants wore the pedometers for a 24-h period in the same position as during the treadmill walking trials. RESULTS: : In general, the SW became less accurate with increasing BMI, increasing waist circumference, and greater pedometer tilt, whereas the NL was not affected by these variables. The SW error scores were significantly correlated with the absolute pedometer tilt angle at all walking speeds (P < 0.05), but the NL error scores were not. On average the NL recorded 1030 +/- 1414 (16.5 +/- 22.7%) more steps that the SW during the 24-h trial. CONCLUSION: In overweight and obese individuals, a piezo-electric pedometer (NL) is more accurate than a spring-levered pedometer (SW), especially at slower walking speeds. In addition, it appears that pedometer tilt; more so than waist circumference and BMI, was the most important factor influencing the accuracy of the SW. The NL accuracy was not affected by pedometer tilt, waist circumference, or BMI.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The main sources of error for waist-worn spring-levered pedometers are slow walking speeds and obesity, both causing underestimation of steps.
“The main sources of error for this class of devices are slow walking speeds and obesity, which both result in underestimation of steps.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [18]
Spring-levered pedometers have diminished accuracy in obese individuals because tilting away from the vertical axis diminishes sensitivity, causing undercounting.
“Spring-levered pedometers have diminished accuracy in obese individuals. According to Crouter et al. [18], this is because when they are tilted away from the vertical axis their sensitivity is diminished, causing them to undercount steps.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [18]
The New Lifestyles NL-2000 and Omron HJ-720 are not impacted by obesity or tilt angle.
“Two such devices (New Lifestyles NL-2000 and Omron HJ-720) are not impacted by obesity or tilt angle [18, 19].”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [18]
Waist-worn accelerometer-based step counters are generally more accurate than spring-levered pedometers.
“Waist-worn accelerometer-based step counters are generally more accurate than spring-levered pedometers.”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [18]
Good step counters can record steps within ±3% during walking at 80.4 m/min (3 mph).
“Good step counters can record steps within this range during walking at 80.4 m/min, or 3 mph [12, 18, 24, 38, 39].”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [18]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
Anthropometric Standardization Reference Manual
Lohman, T. J., Roache, A. F., & Martorell, R. (1992) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199208000-00020 · Cited by 2,764 · see citing works
(1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.17.1855 · Cited by 936 · see citing works
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899 · see citing works
Self-citationPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., Crouter, S. E., & Bassett, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752 · see citing works
Self-citationAccuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., Crouter, S. E., Lukajic, O., & Bassett, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 634 · see citing works
Self-citationAccuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine &amp Science in Sports &amp Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552 · see citing works
Self-citationSelection of anthropometric indicators for classification of abdominal fatness— a critical review
Molarius, A., & Seidell, J. C. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800660 · Cited by 398 · see citing works
Comparison of pedometer and accelerometer measures of free-living physical activity
Tudor-Locke, C. E., Ainsworth, B. E., Thompson, R. W., & Matthews, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 387 · see citing works
Commercially available pedometers: considerations for accurate step counting
Melanson, E. L., Knoll, J. R., Bell, M. L., Donahoo, W. T., Hill, J. O., Nysse, L. J., Lanningham‐Foster, L., Peters, J. C., & Levine, J. A. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2004.01.032 · Cited by 280 · see citing works
Motion Sensor Accuracy under Controlled and Free-Living Conditions
Masurier, G. C. L., Lee, S. M., & Tudor-Locke, C. E. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229 · see citing works
Step activity monitor: Increased accuracy in quantifying ambulatory activity
Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P. (1999) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100170512 · Cited by 182 · see citing works
Relationship between Accumulated Walking and Body Composition in Middle-Aged Women
Thompson, D. L., Rakow, J., & Perdue, S. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126787.14165.b3 · Cited by 162 · see citing works
Comparisons of four methods of estimating physical activity in adult women
Leenders, N., Sherman, W. M., & Nagaraja, H. N. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200007000-00021 · Cited by 161 · see citing works
Effects of Body Mass Index on the Accuracy of an Electronic Pedometer
Swartz, A. M., Bassett, D. R., Jr., Moore, J. B., Thompson, D. L., & Strath, S. J. (2003) · International Journal of Sports Medicine · doi:10.1055/s-2003-43272 · Cited by 124 · see citing works
Amount and Bouts of Physical Activity in a Sample of African-American Women
Whitt, M. C., Kumanyika, S., & Bellamy, S. L. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000093618.60631.c3 · Cited by 43 · see citing works
ACCURACY OF PEDOMETERS IN ADULTS STRATIFIED BY BODY MASS INDEX CATEGORY
Elsenbaumer, K., & Tudor-Locke, C. E. (2003) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200305001-01570 · Cited by 8 · see citing works
Comparison Of Two Waist-mounted And Two Anklemounted Electronic Pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200505001-00146 · Cited by 1 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · see citing works
How many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087 · see citing works
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029 · see citing works
Step Counting: A Review of Measurement Considerations and Health-Related Applications
Bassett, D. R., Toth, L. P., LaMunion, S. R., & Crouter, S. E. (2017) · Sports Medicine · doi:10.1007/s40279-016-0663-1 · Cited by 460 · see citing works
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385 · see citing works
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297 · see citing works
Simultaneous vs Sequential Counseling for Multiple Behavior Change
Hyman, D. J., Pavlik, V. N., Taylor, W. C., Goodrick, G. K., & Moye, L. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.11.1152 · Cited by 188 · see citing works
Evaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159 · see citing works
Self-citationReactivity: an issue for short-term pedometer studies?: Figure 1
Clemes, S. A., Matchett, N., & Wane, S. L. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.038521 · Cited by 106 · see citing works
Time Trends for Step-Determined Physical Activity among Japanese Adults
INOUE, S., OHYA, Y., TUDOR-LOCKE, C., TANAKA, S., YOSHIIKE, N., & SHIMOMITSU, T. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821a5225 · Cited by 81 · see citing works
Yates, T., Davies, M., Gorely, T., Bull, F., & Khunti, K. (2008) · Patient Education and Counseling · doi:10.1016/j.pec.2008.06.010 · Cited by 58 · see citing works
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46 · see citing works
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46 · see citing works
Self-citationEffects of Body Mass Index and Tilt Angle on Output of Two Wearable Activity Monitors
FEITO, Y., BASSETT, D. R., TYO, B., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fefd40 · Cited by 32 · see citing works
Self-citationA comparison of uniaxial and triaxial accelerometers for the assessment of physical activity in dogs
Cheung, K. W., Starling, M. J., & McGreevy, P. D. (2014) · Journal of Veterinary Behavior · doi:10.1016/j.jveb.2013.11.003 · Cited by 12 · see citing works
- Authors
- CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R.
- Affiliations
- Cornell University (US)
- Ball State University (US)
- University of Tennessee at Knoxville (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-10
- Volume
- 37
- Issue
- 10
- Pages
- 1673-1679
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2075354606
- Cited by
- 295
- References
- 19
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 2 · 2022: 7 · 2021: 3 · 2020: 11 · 2019: 8 · 2018: 13 · 2017: 17 · 2016: 23 · 2015: 12 · 2014: 22 · 2013: 21 · 2012: 24
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- overweight adults, obesity, body mass index, waist circumference, walking speed, step counting
- MeSH terms
- Adolescent, Adult, Aged, Body Constitution, Female, Humans, Male, Obesity, Reproducibility of Results, Body Mass Index, Walking, Overweight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review