Cited by 295Physical Activity and HealthContext-Aware Activity Recognition SystemsLower Extremity Biomechanics and Pathologies

Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults

CROUTER, SCOTT E., SCHNEIDER, PATRICK L., BASSETT, DAVID R.·2005·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: The purpose of this study was to examine the effects of BMI, waist circumference, and pedometer tilt on the accuracy of a spring-levered pedometer (Yamax Digiwalker SW-200 (SW)) and a piezo-electric pedometer (New Lifestyles NL-2000 (NL)) during treadmill walking and over a 24-h period in overweight and obese adults. METHODS: Forty participants (40 +/- 13.0 yr, 32.6 +/- 4.8 kg.m) walked on a treadmill at various speeds (54, 67, 80, 94, and 107 m.min) for 3-min stages. Simultaneously, an investigator determined actual steps by a hand counter. For all walking trials the SW and NL were positioned on the right and left waistband, respectively. Height, weight, pedometer tilt angle and circumference measures of the hip and waist were also measured. Thirty-six participants wore the pedometers for a 24-h period in the same position as during the treadmill walking trials. RESULTS: : In general, the SW became less accurate with increasing BMI, increasing waist circumference, and greater pedometer tilt, whereas the NL was not affected by these variables. The SW error scores were significantly correlated with the absolute pedometer tilt angle at all walking speeds (P < 0.05), but the NL error scores were not. On average the NL recorded 1030 +/- 1414 (16.5 +/- 22.7%) more steps that the SW during the 24-h trial. CONCLUSION: In overweight and obese individuals, a piezo-electric pedometer (NL) is more accurate than a spring-levered pedometer (SW), especially at slower walking speeds. In addition, it appears that pedometer tilt; more so than waist circumference and BMI, was the most important factor influencing the accuracy of the SW. The NL accuracy was not affected by pedometer tilt, waist circumference, or BMI.

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000181677.36658.a8

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R.
Affiliations
  • Cornell University (US)
  • Ball State University (US)
  • University of Tennessee at Knoxville (US)
Venue
Medicine & Science in Sports & Exercise
Published
2005-10
Volume
37
Issue
10
Pages
1673-1679
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2075354606
Cited by
295
References
19
Citations by year
2025: 2 · 2024: 2 · 2023: 2 · 2022: 7 · 2021: 3 · 2020: 11 · 2019: 8 · 2018: 13 · 2017: 17 · 2016: 23 · 2015: 12 · 2014: 22 · 2013: 21 · 2012: 24
FWCI
9.59
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
overweight adults, obesity, body mass index, waist circumference, walking speed, step counting
MeSH terms
Adolescent, Adult, Aged, Body Constitution, Female, Humans, Male, Obesity, Reproducibility of Results, Body Mass Index, Walking, Overweight

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review