Reproducibility of a Triaxial Seismic Accelerometer (DynaPort)
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE: To examine the reproducibility of a triaxial seismic accelerometer under controlled conditions and real-life conditions. METHODS: Instrumental reproducibility was examined using a shaker device. The accelerometers (DynaPort MiniMod; McRoberts B.V., The Hague, The Netherlands) were shaken at four frequencies (0.8, 2.1, 3.6, and 4.6 Hz) in x- and y-directions. The magnitude of acceleration ranged from 0 to 1.277g. Additionally, reproducibility under real-life conditions was examined in 55 adolescents (12-17 yr), with the accelerometer attached to the lower back. Each subject walked four short walking trials on level ground at preferred speed. To make this setting meet real-life conditions, we detached and reattached the accelerometer between trials 2 and 3. Detachment of accelerometer between trials 2 and 3 was done by either the same researcher or different researchers (four in total). Intra- and interobserver reproducibility were calculated. RESULTS: Intra- and interinstrumental intraclass correlation coefficients (ICC) were 0.99 for both x- and y-directions. The intrainstrumental coefficients of variance (CoV) were lower than 1.13%. The interinstrumental CoV were lower than 1.37%. Intraobserver ICC was 0.97, and interobserver ICC was 0.88. CONCLUSION: The reproducibility of the accelerometer is high under the controlled conditions of a shaker device and in walking at preferred speed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Hamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
Characteristics of physical activities in daily life in chronic obstructive pulmonary disease
Pitta, F., Troosters, T., Spruit, M. A., Probst, V. S., Decramer, M., & Gosselink, R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-855oc · Cited by 1,256 · cited 1×
“The ability to measure the type of physical activity may be of use in addressing the role of physical activity patterns in the development of obesity and related health risk (11,15) or in COPD (19).”
BackgroundThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Interindividual variation in posture allocation: possible role in human obesity
Levine, J. A., Lanningham-Foster, L. M., McCrady, S. K., Krizan, A. C., Olson, L. R., Kane, P. H., Jensen, M. D., & Clark, M. M. (2005) · Science · doi:10.1126/science.1106561 · Cited by 705 · cited 1×
“The ability to measure the type of physical activity may be of use in addressing the role of physical activity patterns in the development of obesity and related health risk (11,15) or in COPD (19).”
BackgroundJEBB, S. A., & MOORE, M. S. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199911001-00008 · Cited by 314 · cited 1×
“Insufficient physical activity may lead to overweight, obesity (5,13), cardiovascular diseases (10), and type II diabetes (12) in adulthood.”
BackgroundSlootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
Self-citation
Cited by
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citationValidation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
The Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football
Boyd, L. J., Ball, K., & Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.311 · Cited by 556
van Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L., Pomeroy, J., Wareham, N. J., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022922 · Cited by 289
Self-citationProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
“, walking on a treadmill) or assess the reliability of two monitors positioned on the right and left sides of the body (19,25,26,30,33).”
Background
Metadata
- Authors
- VAN HEES, V. T., SLOOTMAKER, S. M., DE GROOT, G., VAN MECHELEN, W., & VAN LUMMEL, R. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2009-04
- Volume
- 41
- Issue
- 4
- Pages
- 810-817
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2129991840
- Cited by
- 70
- References
- 7
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.