CoChat

Comparing the 7-Day Physical Activity Recall with a Triaxial Accelerometer for Measuring Time in Exercise

Open access
SLOANE, RICHARD, SNYDER, DENISE CLUTTER, DEMARK-WAHNEFRIED, WENDY, LOBACH, DAVID, KRAUS, WILLIAM E. · 2009 · Medicine & Science in Sports & Exercise
Cited by 85

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: The primary study aim was to evaluate associations of estimated weekly minutes of moderate-to-vigorous-intensity exercise from self-reports of the telephone-administered 7-Day Physical Activity Recall (7-Day PAR) with data captured by the RT3 triaxial accelerometer. METHODS: This investigation was undertaken as part of the FRESH START study, a randomized clinical trial that tested an iteratively tailored diet and exercise mailed print intervention among newly diagnosed breast and prostate cancer survivors. A convenience sample of 139 medically eligible subjects living within a 60-mile radius of the study center provided both 7-Day PAR and accelerometer data at enrollment. Ultimately, substudy subjects (n = 115) were found eligible for the FRESH START study and randomized to one of two study treatment arms. Follow-up assessments at year 1 (n = 103) and year 2 (n = 99) provided both the 7-Day PAR and the accelerometer data. RESULTS: There was moderate agreement between the 7-Day PAR and the accelerometer with longitudinal serial correlation coefficients of 0.54 (baseline), 0.24 (year 1), and 0.53 (year 2), all P values <0.01, although the accelerometer estimates for weekly time in moderate-to-vigorous physical activity (PA) were much higher than those of the 7-Day PAR at all time points. The two methods were poorly correlated in assessing sensitivity to change from baseline to year 1 (rho = 0.11, P = 0.30). Using mixed models repeated-measures analysis, both methods exhibited similar nonsignificant treatment arm x time interaction P values (7-Day PAR = 0.22, accelerometer = 0.23). CONCLUSIONS: The correlations for three serial time points were in agreement with findings of other studies that compared self-reported time in exercise with PA captured by accelerometry. However, these methods capture somewhat different dimensions of PA and provide differing estimates of change over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e3181984fa8

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
SLOANE, R., SNYDER, D. C., DEMARK-WAHNEFRIED, W., LOBACH, D., & KRAUS, W. E.
Venue
Medicine & Science in Sports & Exercise
Published
2009-06
Volume
41
Issue
6
Pages
1334-1340
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2026047320
Cited by
85
References
7
FWCI
4.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.