Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer

Open access
BONOMI, ALBERTO G., GORIS, ANNELIES H.C., YIN, BIN, WESTERTERP, KLAAS R.·2009·Medicine & Science in Sports & Exercise

Abstract

OBJECTIVE: The aim of this study was to develop models for the detection of type, duration, and intensity of human physical activity using one triaxial accelerometer. METHODS: Twenty subjects (age = 29 +/- 6 yr, BMI = 23.6 +/- 3.2 kg.m) performed 20 selected activities, including walking, running, and cycling, wearing one triaxial accelerometer mounted on the lower back. Identification of activity type was based on a decision tree. The decision tree evaluated attributes (features) of the acceleration signal. The features were measured in intervals of defined duration (segments). Segment size determined the time resolution of the decision tree to assess activity duration. Decision trees with a time resolution of 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 s were developed, and the respective classification performances were evaluated. Multiple linear regression was used to estimate speed of walking, running, and cycling based on acceleration features. RESULTS: Maximal accuracy for the classification of activity type (93%) was reached when the segment size of analysis was 6.4 or 12.8 s. The smaller the segment size, the lower the classification accuracy achieved. Segments of 6.4 s gave the highest time resolution for measuring activity duration without decreasing the classification accuracy. The developed models estimated walking, running, and cycling speeds with a standard error of 0.20, 1.26, and 1.36 km.h, respectively. CONCLUSIONS: This study demonstrated the ability of a triaxial accelerometer in detecting type, duration, and intensity of physical activity using models based on acceleration features. Future studies are needed to validate the presented models in free-living conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e3181a24536

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 245

Metadata

Authors
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R.
Venue
Medicine & Science in Sports & Exercise
Published
2009-09
Volume
41
Issue
9
Pages
1770-1777
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2002566365
Cited by
245
References
5
FWCI
20.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer. https://app.cochat.ai/papers/10.1249/mss.0b013e3181a24536
The paper
BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R. (2009). Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3181a24536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.