The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer
Open accessAbstract
OBJECTIVE: The aim of this study was to develop models for the detection of type, duration, and intensity of human physical activity using one triaxial accelerometer. METHODS: Twenty subjects (age = 29 +/- 6 yr, BMI = 23.6 +/- 3.2 kg.m) performed 20 selected activities, including walking, running, and cycling, wearing one triaxial accelerometer mounted on the lower back. Identification of activity type was based on a decision tree. The decision tree evaluated attributes (features) of the acceleration signal. The features were measured in intervals of defined duration (segments). Segment size determined the time resolution of the decision tree to assess activity duration. Decision trees with a time resolution of 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 s were developed, and the respective classification performances were evaluated. Multiple linear regression was used to estimate speed of walking, running, and cycling based on acceleration features. RESULTS: Maximal accuracy for the classification of activity type (93%) was reached when the segment size of analysis was 6.4 or 12.8 s. The smaller the segment size, the lower the classification accuracy achieved. Segments of 6.4 s gave the highest time resolution for measuring activity duration without decreasing the classification accuracy. The developed models estimated walking, running, and cycling speeds with a standard error of 0.20, 1.26, and 1.36 km.h, respectively. CONCLUSIONS: This study demonstrated the ability of a triaxial accelerometer in detecting type, duration, and intensity of physical activity using models based on acceleration features. Future studies are needed to validate the presented models in free-living conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
HASKELL, W. L., LEE, I.-M., PATE, R. R., POWELL, K. E., BLAIR, S. N., FRANKLIN, B. A., MACERA, C. A., HEATH, G. W., THOMPSON, P. D., & BAUMAN, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180616b27 · Cited by 4,616
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Self-citationJEBB, S. A., & MOORE, M. S. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199911001-00008 · Cited by 314
Physical Activity, Obesity, and the Incidence of Type 2 Diabetes in a High-Risk Population
Kriska, A. M. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg191 · Cited by 259
The role of free-living daily walking in human weight gain and obesity
Levine, J. A., McCrady, S. K., Lanningham-Foster, L. M., Kane, P. H., Foster, R. C., & Manohar, C. U. (2008) · Diabetes · doi:10.2337/db07-0815 · Cited by 148
Cited by
Physical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
Measurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Optimal Placement of Accelerometers for the Detection of Everyday Activities
Cleland, I., Kikhia, B., Nugent, C., Boytsov, A., Hallberg, J., Synnes, K., McClean, S., & Finlay, D. (2013) · Sensors · doi:10.3390/s130709183 · Cited by 401
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Wang, Z., Yang, Z., & Dong, T. (2017) · Sensors · doi:10.3390/s17020341 · Cited by 355
Sensor Positioning for Activity Recognition Using Wearable Accelerometers
Atallah, L., Lo, B., King, R., & Yang, G.-Z. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2160540 · Cited by 346
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
The Use of Wearable Microsensors to Quantify Sport-Specific Movements
Chambers, R., Gabbett, T. J., Cole, M. H., & Beard, A. (2015) · Sports Medicine · doi:10.1007/s40279-015-0332-9 · Cited by 342
Factors Associated With Post-Stroke Physical Activity: A Systematic Review and Meta-Analysis
Thilarajah, S., Mentiplay, B. F., Bower, K. J., Tan, D., Pua, Y. H., Williams, G., Koh, G., & Clark, R. A. (2018) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.09.117 · Cited by 310
Daily physical activity assessment with accelerometers: new insights and validation studies
Plasqui, G., Bonomi, A. G., & Westerterp, K. R. (2013) · Obesity Reviews · doi:10.1111/obr.12021 · Cited by 315
Self-citationSensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2146246 · Cited by 285
Vähä-Ypyä, H., Vasankari, T., Husu, P., Mänttäri, A., Vuorimaa, T., Suni, J., & Sievänen, H. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134813 · Cited by 277
Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
Performance of activity classification algorithms in free-living older adults
SASAKI, J. E., HICKEY, A. M., STAUDENMAYER, J. W., JOHN, D., KENT, J. A., & FREEDSON, P. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000844 · Cited by 112
“Previous studies have reported high recognition rates for their algorithms for predefined activity routines comprising activities of fixed durations in laboratory conditions (1,2,15,19).”
BackgroundPhysical Activity Recognition from Accelerometer Data Using a Multi-Scale Ensemble Method
Zheng, Y., Won, W.-K., Guan, X., & Trost, S. (2013) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v27i2.18997 · Cited by 84
Online human activity recognition using low-power wearable devices
Bhat, G., Deb, R., Chaurasia, V. V., Shill, H., & Ogras, U. Y. (2018) · Proceedings of the International Conference on Computer-Aided Design · doi:10.1145/3240765.3240833 · Cited by 82
“Human activity recognition has been an active area of research due to its applications in health monitoring, patient rehabilitation and in promoting physical activity among the general population [4, 7, 8].”
BackgroundEarly detection of physical activity for people with type 1 diabetes mellitus
Dasanayake, I. S., Bevier, W. C., Castorino, K., Pinsker, J. E., Seborg, D. E., Doyle, F. J., & Dassau, E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815592409 · Cited by 40
Bonomi, A. G., Soenen, S., Goris, A. H. C., & Westerterp, K. R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059641 · Cited by 32
Self-citationRuiz-Zafra, A., Orantes-González, E., Noguera, M., Benghazi, K., & Heredia-Jimenez, J. (2015) · Sensors · doi:10.3390/s150818270 · Cited by 13
Metadata
- Authors
- BONOMI, A. G., GORIS, A. H. C., YIN, B., & WESTERTERP, K. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2009-09
- Volume
- 41
- Issue
- 9
- Pages
- 1770-1777
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2002566365
- Cited by
- 245
- References
- 7
- FWCI
- 20.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.