Comparison of the ActiGraph 7164 and the ActiGraph GT1M during Self-Paced Locomotion
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study compared the ActiGraph accelerometer model 7164 (AM1) with the ActiGraph GT1M (AM2) during self-paced locomotion. METHODS: Participants (n = 116, aged 18-73 yr, mean body mass index = 26.1 kg x m(-2)) walked at self-selected slow, medium, and fast speeds around an indoor circular hallway (0.47 km). Both activity monitors were attached to a belt secured to the hip and simultaneously collected data in 60-s epochs. To compare differences between monitors, the average difference (bias) in count output and steps output was computed at each speed. Time spent in different activity intensities (light, moderate, and vigorous) based on the cut points of Freedson et al. was compared for each minute. RESULTS: The mean +/- SD walking speed was 0.7 +/- 0.22 m x s(-1) for the slow speed, 1.3 +/- 0.17 m x s(-1) for medium, and 2.1 +/- 0.61 m x s(-1) for fast speeds. Ninety-five percent confidence intervals (95% CI) were used to determine significance. Across all speeds, step output was significantly higher for the AM1 (bias = 19.8%, 95% CI = -23.2% to -16.4%) because of the large differences in step output at slow speed. The count output from AM2 was a significantly higher (2.7%, 95% CI = 0.8%-4.7%) than that from AM1. Overall, 96.1% of the minutes were classified into the same MET intensity category by both monitors. CONCLUSIONS: The step output between models was not comparable at slow speeds, and comparisons of step data collected with both models should be interpreted with caution. The count output from AM2 was slightly but significantly higher than that from AM1 during the self-paced locomotion, but this difference did not result in meaningful differences in activity intensity classifications. Thus, data collected with AM1 should be comparable to AM2 across studies for estimating habitual activity levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“to report the first nationally representative data of objectively measured PA in the United States (12,19).”
Self-citationCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 1×
“As shown in Table 5, when the monitors were cross-classified based on the Freedson cut points (7) to estimate activity intensity (i.”
Self-citationAmount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631 · cited 3×
“to report the first nationally representative data of objectively measured PA in the United States (12,19).”
Self-citationHamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Self-citation(2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.2008.00136.x · Cited by 593
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360 · cited 1×
“Studies comparing AM1 to measured steps and to research grade pedometers have concluded that AM1 records extraneous steps and results in higher step counts than the criterion measures (11,21).”
Accelerometer-Determined Steps per Day inUS Adults
TUDOR-LOCKE, C., JOHNSON, W. D., & KATZMARZYK, P. T. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318199885c · Cited by 355
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339 · cited 1×
“Motion sensors are not dependent on the cognitive ability of study participants for accurate PA measurement and are not subject to recall bias associated with self-report tools (4).”
Cited by
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Self-citationValidation of Wearable Monitors for Assessing Sedentary Behavior
KOZEY-KEADLE, S., LIBERTINE, A., LYDEN, K., STAUDENMAYER, J., & FREEDSON, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820ce174 · Cited by 905
Self-citationUsing Accelerometers in Youth Physical Activity Studies: A Review of Methods
Cain, K. L., Sallis, J. F., Conway, T. L., Van Dyck, D., & Calhoon, L. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.3.437 · Cited by 713
Accelerometer-Determined Physical Activity in Adults and Older People
HANSEN, B. H., KOLLE, E., DYRSTAD, S. M., HOLME, I., & ANDERSSEN, S. A. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822cb354 · Cited by 286
Comparison of three generations of ActiGraph™ activity monitors in children and adolescents
Robusto, K. M., & Trost, S. G. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.710761 · Cited by 254
Loyen, A., Clarke-Cornwell, A. M., Anderssen, S. A., Hagströmer, M., Sardinha, L. B., Sundquist, K., Ekelund, U., Steene-Johannessen, J., Baptista, F., Hansen, B. H., et al. (2017) · Sports Medicine · doi:10.1007/s40279-016-0658-y · Cited by 182
Sallis, J. F., Conway, T. L., Cain, K. L., Carlson, J. A., Frank, L. D., Kerr, J., Glanz, K., Chapman, J. E., & Saelens, B. E. (2018) · Preventive Medicine · doi:10.1016/j.ypmed.2018.02.009 · Cited by 181
on behalf of the DEDIPAC consortium, Van Hecke, L., Loyen, A., Verloigne, M., van der Ploeg, H. P., Lakerveld, J., Brug, J., De Bourdeaudhuij, I., Ekelund, U., Donnelly, A., et al. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-016-0396-4 · Cited by 173
Verloigne, M., Loyen, A., Van Hecke, L., Lakerveld, J., Hendriksen, I., De Bourdheaudhuij, I., Deforche, B., Donnelly, A., Ekelund, U., Brug, J., et al. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-016-0395-5 · Cited by 175
Cain, K. L., Conway, T. L., Adams, M. A., Husak, L. E., & Sallis, J. F. (2013) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-10-51 · Cited by 161
“Present results showing less moderate activity with the GT3X+N compared with the 7164 are not consistent with studies showing no significant differences between newer and older generation devices [10-12,16].”
BackgroundResultEvaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Dalene, K. E., Anderssen, S. A., Andersen, L. B., Steene‐Johannessen, J., Ekelund, U., Hansen, B. H., & Kolle, E. (2018) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12876 · Cited by 121
Nihill, G. F. J., Lubans, D. R., & Plotnikoff, R. C. (2013) · Mental Health and Physical Activity · doi:10.1016/j.mhpa.2012.02.003 · Cited by 38
Effects of Body Mass Index and Tilt Angle on Output of Two Wearable Activity Monitors
FEITO, Y., BASSETT, D. R., TYO, B., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fefd40 · Cited by 32
Metadata
- Authors
- KOZEY, S. L., STAUDENMAYER, J. W., TROIANO, R. P., & FREEDSON, P. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2010-05
- Volume
- 42
- Issue
- 5
- Pages
- 971-976
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2075665734
- Cited by
- 113
- References
- 11
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.