Comment on “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip and Wrist”
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In the article, “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist” (3), the authors provide evidence that a hip-worn accelerometer estimates activity energy expenditure and classifies activity type and sedentary behavior more accurately than a wrist-worn accelerometer. This study is an important and timely contribution improving our understanding of how accelerometer placement affects the accuracy in estimating physical activity and sedentary behavior metrics. As acknowledged by the authors, this conclusion is based on using simple analytic procedures and summary data from a derived acceleration measure that eliminates much of the raw acceleration signal features that could potentially improve the estimates. Other studies using the raw acceleration signal have shown that the wrist-worn monitor provides reasonably accurate and precise estimates of activity type (4), energy expenditure, activity intensity, and sedentary behavior (1). Use of a derived summary measure from the accelerometer has other limitations. Average accelerometer count values may lead to activity intensity misclassification (2). Specifically, similar average activity counts for activities with different energy expenditure levels and similar energy expenditure levels with different activity counts have been reported. Nevertheless, the authors used these derived accelerometer counts since accelerometer data are typically reported in this manner. Additional evidence about the performance of newer machine learning processing of the raw acceleration signal is necessary to ultimately determine the utility of wrist-worn accelerometers. The authors point out that a wrist-worn accelerometer may be particularly inaccurate for detecting sedentary behaviors since arm movements may occur during sedentary time (i.e., seated and talking with arm movements). It is possible, however, that advanced computational methods may be able to detect these kinds of arm movements and differentiate them from arm activity where energy expenditure is increased. There are some advantages to using a wrist-worn accelerometer. NHANES is currently collecting data using an accelerometer worn on the wrist so that the monitor is worn 24 h·d−1, making it possible to collect sleep measures. In addition, wear compliance is improved with a monitor worn on the wrist. In the first NHANES hip-worn accelerometer study (2003–2006), 40%–70% of participants (compliance varied by age group) had 6+ d of data with 10 h·d−1 of wear time. In the current NHANES wrist-worn accelerometer study (2011–2012), compliance has been 70%–80% (6+ d of data) with a median wear time of 21–22 h·d−1 (R. Troiano and J. McClain, personal communication). Traditionally, cut points developed and validated in laboratory calibration studies were applied to the data collected in the field. This approach has limitations and likely leads to field-based activity intensity misclassification. Using advanced computation methods applied to the raw acceleration signal may improve estimates of free-living physical activity and sedentary behavior measures. To address this issue, algorithms should first be developed using a broad range of activities that are most prevalent in day-to-day activity. Second, cross validation of the algorithms in the free-living setting is needed where activities do not occur in fixed time intervals and are often performed in sporadic and unpredictable patterns. This strategy will ensure a fair comparison of findings across studies by eliminating the strong influence of activity type on prediction accuracy. While this new method may challenge the traditional research paradigm of calibrating activity monitors exclusively in controlled conditions, it can maximally harness the potential of advanced data processing techniques that adapt and improve prediction. This will be particularly important when there is variability in acceleration patterns due to random movements when activities are performed in natural settings. The adaptability of these techniques combined with the richness of the raw acceleration signal may help to discern different activities and identify transitions between activities. However, there is no question that the computation power demands and data storage requirements will be significant. Collaboration with experts in mathematics, statistics, computer science, and engineering is essential for success in finding solutions to these challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 1×
“Other studies using the raw acceleration signal have shown that the wrist-worn monitor provides reasonably accurate and precise estimates of activity type (4), energy expenditure, activity intensity, and sedentary behavior (1).”
BackgroundPhysical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222
Self-citation
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744
“The wrist-worn version of such accelerometers has become popular, especially in large population studies [4–7], as compliance is equal or better than waist-worn devices [8–10] and it allows assessment of both physical activity and sleep.”
BackgroundAccelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Field evaluation of a random forest activity classifier for wrist-worn accelerometer data
Pavey, T. G., Gilson, N. D., Gomersall, S. R., Clark, B., & Trost, S. G. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2016.06.003 · Cited by 174
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
“, smart watch), enable sleep detection, and promote participant compliance (15).”
BackgroundHekler, E. B., Buman, M. P., Grieco, L., Rosenberger, M., Winter, S. J., Haskell, W., & King, A. C. (2015) · JMIR mhealth and uhealth · doi:10.2196/mhealth.3505 · Cited by 137
Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.
Scott, J. J., Rowlands, A. V., Cliff, D. P., Morgan, P. J., Plotnikoff, R. C., & Lubans, D. R. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.04.017 · Cited by 120
Rowlands, A. V. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2018-0201 · Cited by 87
Shelley, J., Fairclough, S. J., Knowles, Z. R., Southern, K. W., McCormack, P., Dawson, E. A., Graves, L. E. F., & Hanlon, C. (2018) · BMC Pediatrics · doi:10.1186/s12887-018-1301-x · Cited by 31
Surveillance of Youth Physical Activity and Sedentary Behavior with Wrist Accelerometry
Kim, Y., Hibbing, P., Saint-Maurice, P. F., Ellingson, L. D., Hennessy, E., Wolff-Hughes, D. L., Perna, F. M., & Welk, G. J. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2017.01.012 · Cited by 29
Validation study of Polar V800 accelerometer
Hernández-Vicente, A., Santos-Lozano, A., De Cocker, K., & Garatachea, N. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.07.16 · Cited by 23
Metadata
- Authors
- FREEDSON, P. S., & JOHN, D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2013-05
- Volume
- 45
- Issue
- 5
- Pages
- 962-963
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1977919075
- Cited by
- 90
- References
- 3
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.