Integral Value of JT Interval in Magnetocardiography is Sensitive to Coronary Stenosis and Improves Soon After Coronary Revascularization
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Magnetocardiography (MCG) is sensitive to minute cardiac electric abnormalities, but its clinical utility in diagnosing ischemic heart disease (IHD) has not been established. The present study examined the usefulness of an integral MCG value of ventricular repolarization in patients with IHD. METHODS AND RESULTS: MCG was performed at rest in 14 patients with coronary stenosis >75% confirmed by coronary angiography (IHD group) using a 64-channel system, and then the sum of the 64-channel integral values of the QRS or JT intervals (QRSi and JTi, respectively) was calculated. The JTi/QRSi value indicated the total power of currents in JT compared with those in QRS. These measurements were repeated within 2 weeks after coronary revascularization. The Control group comprised 30 healthy volunteers. The baseline value of JTi/QRSi was significantly smaller in the IHD than in the Control group, but after revascularization it increased and did not significantly differ from the Control group. No significant difference in ST deviation was identified by electrocardiography (ECG) before and after coronary revascularization. Analysis of the Control group revealed that JTi/QRSi was not affected by age. CONCLUSIONS: The JTi/QRSi of the MCG is more sensitive to coronary stenosis than ECG, and this parameter improves soon after coronary revascularization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cohen, D., & Kaufman, L. A. (1975) · Circulation Research · doi:10.1161/01.res.36.3.414 · Cited by 131
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109
Hänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74
Baule, G. M., & McFee, R. (1970) · American Heart Journal · doi:10.1016/0002-8703(70)90312-1 · Cited by 69
Magnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42
Hailer, B., Leeuwen, P. V., Lange, S., & Wehr, M. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90103-6 · Cited by 39
Cited by
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57
“T interval has been proven to provide high detection sensitivity to cardiac abnormality [45,46].”
BackgroundKurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“According to previous studies, early diagnoses of ischemic heart disease [22], follow-up before and after coronary revascularizations [5] and prognosis”
BackgroundLim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29
Shin, E.-S., Chung, J.-H., Park, S. G., Saleh, A., Lam, Y.-Y., Bhak, J., Jung, F., Morita, S., & Brachmann, J. (2019) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-180485 · Cited by 20
Metadata
- Authors
- On, K., Watanabe, S., Yamada, S., Takeyasu, N., Nakagawa, Y., Nishina, H., Morimoto, T., Aihara, H., Kimura, T., Sato, Y., Tsukada, K., Kandori, A., Miyashita, T., Ogata, K., Suzuki, D., Yamaguchi, I., & Aonuma, K.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2007
- Volume
- 71
- Issue
- 10
- Pages
- 1586-1592
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2015006354
- Cited by
- 32
- References
- 6
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.