Impact of Target Lesion Coronary Calcification on Stent Expansion: – An Optical Coherence Tomography Study –

Open access
Kobayashi, Yuhei, Okura, Hiroyuki, Kume, Teruyoshi, Yamada, Ryotaro, Kobayashi, Yukari, Fukuhara, Kenzo, Koyama, Terumasa, Nezuo, Shintaro, Neishi, Yoji, Hayashida, Akihiro, Kawamoto, Takahiro, Yoshida, Kiyoshi · 2014 · Circulation Journal

Abstract

BACKGROUND: Stent underexpansion remains a concern as a cause of drug-eluting stent (DES) failure. Although coronary calcification is considered to be a contributing factor in stent underexpansion, previous intravascular ultrasound studies have failed to demonstrate this relationship. We investigated whether stent expansion could be predicted by coronary calcification as assessed by optical coherence tomography (OCT). METHODS AND RESULTS: We enrolled 51 de novo native coronary artery lesions treated by a single 2nd-generation DES (3 types). Prior to stent deployment, the arc and area of calcium at the target lesion were measured using OCT. After successful stent implantation, OCT imaging was repeated to assess minimal stent diameter and area (MSD and MSA). Stent expansion was defined as MSD (or MSA) divided by the values predicted by the manufacturers' compliance charts. Patients were divided into 4 groups according to the median values of the arc and area of calcium. Mean stent expansion was 73.3±8.7% for MSD and 65.2±12.0% for MSA. Stent expansion defined by MSD was significantly different among the 4 groups (P=0.02). A similar trend was observed for stent expansion defined by MSA (P=0.16). CONCLUSIONS: The extent of target lesion calcification as assessed by OCT may be an important determinant of the expansion of 2nd-generation DES.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1253/circj.cj-14-0108

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 262

Metadata

Authors
Kobayashi, Y., Okura, H., Kume, T., Yamada, R., Kobayashi, Y., Fukuhara, K., Koyama, T., Nezuo, S., Neishi, Y., Hayashida, A., Kawamoto, T., & Yoshida, K.
Venue
Circulation Journal
Published
2014
Volume
78
Issue
9
Pages
2209-2214
ISSN
  • 1346-9843 (ISSN-L)
  • 1347-4820
OpenAlex
W2019535964
Cited by
262
References
6
FWCI
8.96
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Target Lesion Coronary Calcification on Stent Expansion: – An Optical Coherence Tomography Study –. https://app.cochat.ai/papers/10.1253/circj.cj-14-0108
The paper
Kobayashi, Y., Okura, H., Kume, T., Yamada, R., Kobayashi, Y., Fukuhara, K., Koyama, T., Nezuo, S., Neishi, Y., Hayashida, A., Kawamoto, T., & Yoshida, K. (2014). Impact of Target Lesion Coronary Calcification on Stent Expansion: – An Optical Coherence Tomography Study –. Circulation Journal. https://doi.org/10.1253/circj.cj-14-0108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.