CoChat

Comparison of Three Types of Mass Spectrometer for High-Performance Liquid Chromatography/Mass Spectrometry Analysis of Perfluoroalkylated Substances and Fluorotelomer Alcohols

Berger, Urs, Langlois, Ingrid, Oehme, Michael, Kallenborn, Roland · 2004 · European Journal of Mass Spectrometry
Cited by 83

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The performance of three different types of mass spectrometer (MS) coupled to high performance liquid chromatography (HPLC), was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). An ion trap MS in the full-scan and product-ion mass spectrometry (MS 2) mode, time-of-flight (ToF) high-resolution MS and quadrupole MS in the selected ion mode, as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative-ion mode [ESI(–)] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product-ion spectra obtained by in-source and collision-induced dissociation fragmentation are discussed, including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent of the applied MS instrument. Ion trap MS 2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS 2 mode, it was not sensitive enough for selective trace amount quantification. ToF high-resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibilities of MS/MS. Triple-quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, although its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for ToF MS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1255/ejms.679

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Berger, U., Langlois, I., Oehme, M., & Kallenborn, R.
Venue
European Journal of Mass Spectrometry
Published
2004-10
Volume
10
Issue
5
Pages
579-588
ISSN
  • 1356-1049 (ISSN-L)
  • 1469-0667
  • 1751-6838
OpenAlex
W2008199301
Cited by
83
References
3
FWCI
2.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.