Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC: need for assay-specific decision limits and metabolite-specific assays
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Clinical demand for quick, cheap, precise and accurate 25-hydroxyvitamin D (25(OH)D) results has led to the development of a variety of assay methods. Lack of standardization of these methods has resulted in intermethod disagreement and challenged whether current assays recognize 25(OH)D 2 and 25(OH)D 3 equally. Methods: We studied 172 patient samples from hip fracture cases using DiaSorin (DS) and IDS radioimmunoassays and the Nichols Advantage-automated protein binding assay (NA-CLPBA) in comparison to high-performance liquid chromatography (HPLC). 52 patient samples were analysed before and after three months treatment with 1000 IU of daily ergocalciferol (vitamin D 2). Results: Linear regression analysis in pre-treatment samples demonstrated a positive Y-intercept for each immunoassay compared with HPLC, and a slope that varied from 0.64 (IDS) to 0.97 (DS, NA-CLPBA). Bland Altman analysis demonstrated that all the three assays had a proportional positive bias relative to HPLC at values from 20 to 50 nmol/L. Regression analysis of post-treatment samples demonstrated a slope that was not significantly different from zero for the IDS and NA-CLPBA and 0.2 for the DS method, with a positive intercept for all assays of between 8 and 22, indicating less than 50% of 25(OH)D 2 measured by HPLC was detected. Conclusions: These results demonstrate the need for assay-specific decision limits for 25(OH)D 3 in order to define appropriate thresholds for treatment institution. Treatment with vitamin D 2 may not be accurately monitored with any of the three commercial assays studied. Clinicians and biochemists who continue to use 25(OH)D assays need to be urgently informed of these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Vitamin D for health: a global perspective
Hossein-nezhad, A., & Holick, M. F. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.05.011 · Cited by 1,298
“commonly used Food and Drug Administrationeapproved pharmaceutical form of vitamin D); the absence of a rise in the total 25(OH)D level may indicate nonadherence ormalabsorption.(223) For these patients, use of the gold standard LCMS/MS would quantitatively report 25(OH)D2, 25(OH)D3, and total 25(OH)D levels.”
Fraser, W. D. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60507-9 · Cited by 934
Self-citationVitamin D levels and early mortality among incident hemodialysis patients
Wolf, M., Shah, A., Gutierrez, O., Ankers, E., Monroy, M., Tamez, H., Steele, D., Chang, Y., Camargo, C. A., Tonelli, M., et al. (2007) · Kidney International · doi:10.1038/sj.ki.5002451 · Cited by 789
Farrell, C.-J. L., Martin, S., McWhinney, B., Straub, I., Williams, P., & Herrmann, M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.172155 · Cited by 373
Wallace, A. M., Gibson, S., de la Hunty, A., Lamberg-Allardt, C., & Ashwell, M. (2010) · Steroids · doi:10.1016/j.steroids.2010.02.012 · Cited by 311
Roth, H. J., Schmidt-Gayk, H., Weber, H., & Niederau, C. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2007.007091 · Cited by 309
Close, G. L., Russell, J., Cobley, J. N., Owens, D. J., Wilson, G., Gregson, W., Fraser, W. D., & Morton, J. P. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2012.733822 · Cited by 246
“In this regard, recent recommendations state that both vitamin D2 and D3 should be assessed using high performance liquid chromatography mass spectrometry (Tandem MS) to allow an accurate assessment of 25(OH)D concentration (Fraser, 2009; Glendenning et al., 2003, 2006; Holick, 2005).”
BackgroundDetermining Vitamin D Status: A Comparison between Commercially Available Assays
Snellman, G., Melhus, H., Gedeborg, R., Byberg, L., Berglund, L., Wernroth, L., & Michaëlsson, K. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011555 · Cited by 236
“Assay-specific decision limits to define appropriate thresholds for insufficiency have been suggested as a solution [19] but that will be cumbersome for the clinician.”
BackgroundMethodResultInfluentialAn evaluation of automated methods for measurement of serum 25-hydroxyvitamin D
Wagner, D., Hanwell, H. E. C., & Vieth, R. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.07.013 · Cited by 191
“As a result, some groups have emphasized a need for appropriate reference materials and standardization of 25(OH)D assays [15,16].”
BackgroundSerum 25-Hydroxyvitamin D Levels: Variability, Knowledge Gaps, and the Concept of a Desirable Range
El-Hajj Fuleihan, G., Bouillon, R., Clarke, B., Chakhtoura, M., Cooper, C., McClung, M., & Singh, R. J. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2536 · Cited by 176
Vitamin D Assays: Past and Present Debates, Difficulties, and Developments
Fraser, W. D., & Milan, A. M. (2013) · Calcified Tissue International · doi:10.1007/s00223-012-9693-3 · Cited by 160
“In a Vitamin D2 (ergocalciferol) supplementation study, venous sampling following oral administration of Vitamin D2 demonstrated a significant underestimation of 25OHD2 by three immunoassays [21].”
Self-citationDeterminants of vitamin D status in a general population of Danish adults
Thuesen, B., Husemoen, L., Fenger, M., Jakobsen, J., Schwarz, P., Toft, U., Ovesen, L., Jørgensen, T., & Linneberg, A. (2012) · Bone · doi:10.1016/j.bone.2011.12.016 · Cited by 158
Close, G. L., Leckey, J., Patterson, M., Bradley, W., Owens, D. J., Fraser, W. D., & Morton, J. P. (2013) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-091735 · Cited by 155
Self-citationVitamin D Endocrine System and the Immune Response in Rheumatic Diseases
Cutolo, M., Plebani, M., Shoenfeld, Y., Adorini, L., & Tincani, A. (2011) · Vitamins & Hormones · doi:10.1016/b978-0-12-386960-9.00014-9 · Cited by 86
Metadata
- Authors
- Glendenning, P., Taranto, M., Noble, J., Musk, A., Hammond, C., Goldswain, P., Fraser, W., & Vasikaran, S.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2006-01-01
- Volume
- 43
- Issue
- 1
- Pages
- 23-30
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2145243501
- Cited by
- 122
- References
- 1
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.