Clinical accuracy of midnight salivary cortisol measured by automated electrochemiluminescence immunoassay method in Cushing's syndrome
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: The diagnosis of Cushing's syndrome (CS) represents a challenge for endocrinologists. Several screening tests are used, but none of them seems to be the gold standard for the diagnosis. The aim of this study was to confirm the diagnostic value of salivary cortisol (SC) as a first-level screening test and to evaluate the clinical performance of a electrochemiluminescence immunoassay (ECLIA) method. Methods: In 33 patients with a strong clinical suspicion of CS, we evaluated urinary free cortisol, circadian rhythm plasma cortisol (PC) and morning PC after low-dose dexamethasone suppression test (LDDST). At the same sampling times, we evaluated SC analysed by the same automated method. Correlation studies were evaluated by Spearman index (significance P < 0.05). Results: On the basis of biochemical results CS was confirmed in 21/33. SC was significantly correlated to PC at 12:00 and 23:00. Thus, we chose 8.3 nmol/L as midnight SC cut-off value with 100% sensitivity and 97.4% specificity. The cut-off chosen after LDDST was 1.7 nmol/L (100% sensitivity and 72% specificity). Conclusion: SC assay showed a good clinical accuracy and the ECLIA method can be used in clinical routine to obtain fast results easily.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The diagnosis of Cushing's syndrome: an Endocrine Society Clinical Practice Guideline.
Nieman, L. K., Biller, B. M. K., Findling, J. W., Newell-Price, J., Savage, M. O., Stewart, P. M., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0125 · Cited by 2,718
Diagnosis and complications of Cushing’s syndrome: a consensus statement
Arnaldi, G., Angeli, A., Atkinson, A. B., Bertagna, X., Cavagnini, F., Chrousos, G. P., Fava, G. A., Findling, J. W., Gaillard, R. C., Grossman, A. B., et al. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030871 · Cited by 1,362
Nighttime salivary cortisol: a useful test for the diagnosis of Cushing's syndrome.
Papanicolaou, D. A., Mullen, N., Kyrou, I., & Nieman, L. K. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020534 · Cited by 241
Utility of salivary cortisol measurements in Cushing's syndrome and adrenal insufficiency
Raff, H. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-1166 · Cited by 186
Putignano, P., Toja, P., Dubini, A., Giraldi, F. P., Corsello, S. M., & Cavagnini, F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030312 · Cited by 182
Self-citation
Cited by
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
“ECLIA has found application in many clinical studies for cortisol detection in human samples for Cushing’s syndrome (Carrozza et al., 2010; Yaneva et al., 2009), obesity (Belaya et al.”
BackgroundMethodAccuracy of laboratory tests for the diagnosis of Cushing syndrome
Galm, B. P., Qiao, N., Klibanski, A., Biller, B. M. K., & Tritos, N. A. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa105 · Cited by 100
Ceccato, F., Marcelli, G., Martino, M., Concettoni, C., Brugia, M., Trementino, L., Michetti, G., & Arnaldi, G. (2019) · Journal of Endocrinological Investigation · doi:10.1007/s40618-018-0921-1 · Cited by 38
Biochemical diagnosis of Cushing’s disease: Screening and confirmatory testing
Petersenn, S. (2021) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2021.101519 · Cited by 33
Metadata
- Authors
- Carrozza, C., Corsello, S. M., Paragliola, R. M., Ingraudo, F., Palumbo, S., Locantore, P., Sferrazza, A., Pontecorvi, A., & Zuppi, C.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2010-04-20
- Volume
- 47
- Issue
- 3
- Pages
- 228-232
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2000221969
- Cited by
- 47
- References
- 5
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical accuracy of midnight salivary cortisol measured by automated electrochemiluminescence immunoassay method in Cushing's syndrome. https://app.cochat.ai/papers/10.1258/acb.2010.010020
- The paper
- Carrozza, C., Corsello, S. M., Paragliola, R. M., Ingraudo, F., Palumbo, S., Locantore, P., Sferrazza, A., Pontecorvi, A., & Zuppi, C. (2010). Clinical accuracy of midnight salivary cortisol measured by automated electrochemiluminescence immunoassay method in Cushing's syndrome. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/acb.2010.010020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.