Analytical error and interference in immunoassay: minimizing risk
Open accessAbstract
Although generally robust, immunoassays remain vulnerable to occasional analytical errors that may have serious implications for patient care. Sporadic errors that occur as a result of properties of the specimen are particularly difficult to detect. They may be due to the presence of cross-reacting substances, antianalyte antibodies or antireagent antibodies, all of which may lead to erroneously high or low results. Low results may be observed for tumour markers due to high-dose hooking in the presence of very high analyte concentrations. Erroneous results can occur unexpectedly with any specimen and there is no practical means of identifying specimens likely to cause problems in immunoassays. The possibility of interference should always be considered when results do not appear to be in accord with the clinical picture. Errors can occur in even the best-managed laboratories and their early investigation is always desirable. If there is any doubt whatsoever about a result, clinical staff should be encouraged to contact the laboratory. Investigations for possible interference that can be undertaken in most laboratories include testing for linearity on dilution, recovery experiments, treatment with heterophilic blocking tubes and confirmation using a different method. It may be desirable to consult specialist laboratories if more complex studies are necessary. Informing clinical and laboratory staff of the ever-present possibility of unexpected interference, ensuring brief clinical details are available to laboratory staff, and above all facilitating excellent communication between laboratory and clinical staff are key to minimizing the risk of clinical mismanagement due to unsuspected interference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hoofnagle, A. N., Becker, J. O., Wener, M. H., & Heinecke, J. W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.109652 · Cited by 314
Wong, T., Shackleton, C. H., Covey, T. R., & Ellis, G. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1830 · Cited by 159
Bates, K. J., Hall, E. M., Fahie-Wilson, M. N., Kindler, H., Bailey, C., Lythall, D., & Lamb, E. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.133546 · Cited by 69
Cited by
Guidelines for the management of thyroid cancer
Perros, P., Boelaert, K., Colley, S., Evans, C., Evans, R. M., Gerrard BA, G., Gilbert, J., Harrison, B., Johnson, S. J., Giles, T. E., et al. (2014) · Clinical Endocrinology · doi:10.1111/cen.12515 · Cited by 1,372
Translation of proteomic biomarkers into FDA approved cancer diagnostics: issues and challenges
Füzéry, A. K., Levin, J., Chan, M. M., & Chan, D. W. (2013) · Clinical Proteomics · doi:10.1186/1559-0275-10-13 · Cited by 428
Application of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Park, J. Y., & Kricka, L. J. (2013) · The Immunoassay Handbook · doi:10.1016/b978-0-08-097037-0.00027-0 · Cited by 365
Variability and Error in Cardiac Troponin Testing
Herman, D. S., Kavsak, P. A., & Greene, D. N. (2017) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqx066 · Cited by 87
Metadata
- Authors
- Sturgeon, C. M., & Viljoen, A.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2011-07-12
- Volume
- 48
- Issue
- 5
- Pages
- 418-432
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2325763399
- Cited by
- 228
- References
- 3
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytical error and interference in immunoassay: minimizing risk. https://app.cochat.ai/papers/10.1258/acb.2011.011073
- The paper
- Sturgeon, C. M., & Viljoen, A. (2011). Analytical error and interference in immunoassay: minimizing risk. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/acb.2011.011073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.