Proton radiography and tomography with application to proton therapy
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536 · cited 1×
“Figures are based on simulations by the authors using the FLUKA Monte Carlo code.(18) Gaussian fits were used to determine sx, su and sR and root mean square deviation to determine sE.”
MethodRepresentation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
The calibration of CT Hounsfield units for radiotherapy treatment planning
Schneider, U., Pedroni, E., & Lomax, A. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/009 · Cited by 1,093 · cited 2×
“However, SPR, that is, the ratio of stopping power at a point relative to that for water, is approximately constant with energy and its slow variation is well understood.(3) It is this fact that makes proton transmission imaging potentially so useful for treatment planning.”
In vivoproton range verification: a review
Knopf, A. C., & Lomax, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/15/r131 · Cited by 620 · cited 1×
“The latter two (GIVI and PET) primarily promise benefit for in vivo range verification (inferring the depths that protons penetrated).(15) Finally, we emphasize that our interest in this review is with protons.”
Janni, J. (1982) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(82)90004-3 · Cited by 488 · cited 1×
“The standard deviation in range straggling typically slightly exceeds 1% of the range.(19)”
Wrixon, A. D. (2008) · Journal of Radiological Protection · doi:10.1088/0952-4746/28/2/r02 · Cited by 405 · cited 1×
“Quoted figure based on a crude calculation of comparable stochastic risk to typical X-ray CT head scans ( 40mGy(7,8)), assuming a proton radiation weighting factor twice that of photons.(9) BJR G Poludniowski et al”
MethodPatient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
Schulte, R., Bashkirov, V., Li, T., Liang, Z., Mueller, K., Heimann, J., Johnson, L. R., Keeney, B., Sadrozinski, H. F.-W., Seiden, A., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829392 · Cited by 224
A maximum likelihood proton path formalism for application in proton computed tomography
Schulte, R. W., Penfold, S. N., Tafas, J., & Schubert, K. E. (2008) · Medical Physics · doi:10.1118/1.2986139 · Cited by 222 · cited 1×
“The RMS error (RMSE) in reconstructing the proton path inside a patient, owing to MCS within the patient, is of order 1mm even when using non-linear path estimates.(48) Based on this figure, a tracker resolution of sr, 1mm is probably sufficient to consider its contribution sub-dominant.”
Total variation superiorization schemes in proton computed tomography image reconstruction
Penfold, S. N., Schulte, R. W., Censor, Y., & Rosenfeld, A. B. (2010) · Medical Physics · doi:10.1118/1.3504603 · Cited by 110 · cited 2×
“Some success has been shown with: an optimal linear ray binning for FBP,(83) depth-dependent and voxel-specific backprojection for FBP,(84) a list-mode backprojection-then-filtering algorithm(85) and iterative reconstruction.(47,51) As is thematic with tomographic reconstruction, iterative reconstruction provides the…”
Total variation superiorization schemes in proton computed tomography image reconstruction
Penfold, S., Schulte, R. W., Censor, Y., & Rosenfeld, A. B. (2010) · Research Online (University of Wollongong) · Cited by 104
A more accurate reconstruction system matrix for quantitative proton computed tomography
Penfold, S. N., Rosenfeld, A. B., Schulte, R. W., & Schubert, K. E. (2009) · Medical Physics · doi:10.1118/1.3218759 · Cited by 62
Heavy ion radiography and tomography
Parodi, K. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.02.004 · Cited by 53
Karonis, N. T., Duffin, K. L., Ordoñez, C. E., Erdelyi, B., Uram, T. D., Olson, E. C., Coutrakon, G. B., & Papka, M. E. (2013) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2013.07.016 · Cited by 28 · cited 1×
“Even so, with appropriate parallelization, it has been shown that even list-mode iterative reconstruction is possible in under 8min with current technology.(86) pCT is therefore now feasible for online (near real time) image-guidance and verification in the clinic as well as for off-line planning.”
Relativistic protons for image-guided stereotactic radiosurgery
Durante, M., & Horst Stöcker, B. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/373/1/012016 · Cited by 12 · cited 1×
“High spatial resolution images have been demonstrated in such a scheme with relativistic protons (800MeV).(74) BJR G Poludniowski et al”
Cited by
Roadmap: proton therapy physics and biology
Paganetti, H., Beltran, C., Both, S., Dong, L., Flanz, J., Furutani, K., Grassberger, C., Grosshans, D. R., Knopf, A.-C., Langendijk, J. A., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abcd16 · Cited by 175
Online daily adaptive proton therapy
Albertini, F., Matter, M., Nenoff, L., Zhang, Y., & Lomax, A. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190594 · Cited by 165
All the fun of the FAIR: fundamental physics at the facility for antiproton and ion research
Durante, M., Indelicato, P., Jonson, B., Koch, V, Langanke, K., Meißner, U.-G., Nappi, E., Nilsson, T., Stöhlker, T., Widmann, E., et al. (2019) · Physica Scripta · doi:10.1088/1402-4896/aaf93f · Cited by 129
Applied nuclear physics at the new high-energy particle accelerator facilities
Durante, M., Golubev, A., Park, W.-Y., & Trautmann, C. (2019) · Physics Reports · doi:10.1016/j.physrep.2019.01.004 · Cited by 72
Metadata
- Authors
- Poludniowski, G., Allinson, N. M., & Evans, P. M.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-09
- Volume
- 88
- Issue
- 1053
- Pages
- 20150134
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W645348099
- Cited by
- 170
- References
- 16
- FWCI
- 13.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.