Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Patient Radiation Doses from Adult and Pediatric CT

Huda, Walter, Vance, Awais·2007·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of our study was to determine typical organ doses, and the corresponding effective doses, to adult and pediatric patients undergoing a single CT examination. MATERIALS AND METHODS: Heads, chests, and abdomens of patients ranging from neonates to oversized adults (120 kg) were modeled as uniform cylinders of water. Monte Carlo dosimetry data were used to obtain average doses in the directly irradiated region. Dosimetry data were used to compute the total energy imparted, which was converted into the corresponding effective dose using patient-size-dependent effective-dose-per-unit-energy-imparted coefficients. Representative patient doses were obtained for scanning protocols that take into account the size of the patient being scanned by typical MDCT scanners. RESULTS: Relative to CT scanners from the early 1990s, present-day MDCT scanners result in doses that are approximately 1.5 and approximately 1.7 higher per unit mAs in head and body phantoms, respectively. Organ absorbed doses in head CT scans increase from approximately 30 mGy in newborns to approximately 40 mGy in adults. Patients weighing less than approximately 20 kg receive body organ absorbed doses of approximately 7 mGy, which is a factor of 2 less than for normal-sized (70-kg) adults. Adult head CT effective doses are approximately 0.9 mSv, four times less than those for the neonate. Effective doses for neonates undergoing body CT are approximately 2.5 mSv, whereas those for normal-sized adults are approximately 3.5 mSv. CONCLUSION: Representative organ absorbed doses in CT are substantially lower than threshold doses for the induction of deterministic effects, and effective doses are comparable to annual doses from natural background radiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.06.0101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 251

Metadata

Authors
Huda, W., & Vance, A.
Venue
American Journal of Roentgenology
Published
2007-02
Volume
188
Issue
2
Pages
540-546
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2126577566
Cited by
251
References
1
FWCI
15.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient Radiation Doses from Adult and Pediatric CT. https://app.cochat.ai/papers/10.2214/ajr.06.0101
The paper
Huda, W., & Vance, A. (2007). Patient Radiation Doses from Adult and Pediatric CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.06.0101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.