The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Patient Radiation Doses from Adult and Pediatric CT
Abstract
OBJECTIVE: The purpose of our study was to determine typical organ doses, and the corresponding effective doses, to adult and pediatric patients undergoing a single CT examination. MATERIALS AND METHODS: Heads, chests, and abdomens of patients ranging from neonates to oversized adults (120 kg) were modeled as uniform cylinders of water. Monte Carlo dosimetry data were used to obtain average doses in the directly irradiated region. Dosimetry data were used to compute the total energy imparted, which was converted into the corresponding effective dose using patient-size-dependent effective-dose-per-unit-energy-imparted coefficients. Representative patient doses were obtained for scanning protocols that take into account the size of the patient being scanned by typical MDCT scanners. RESULTS: Relative to CT scanners from the early 1990s, present-day MDCT scanners result in doses that are approximately 1.5 and approximately 1.7 higher per unit mAs in head and body phantoms, respectively. Organ absorbed doses in head CT scans increase from approximately 30 mGy in newborns to approximately 40 mGy in adults. Patients weighing less than approximately 20 kg receive body organ absorbed doses of approximately 7 mGy, which is a factor of 2 less than for normal-sized (70-kg) adults. Adult head CT effective doses are approximately 0.9 mSv, four times less than those for the neonate. Effective doses for neonates undergoing body CT are approximately 2.5 mSv, whereas those for normal-sized adults are approximately 3.5 mSv. CONCLUSION: Representative organ absorbed doses in CT are substantially lower than threshold doses for the induction of deterministic effects, and effective doses are comparable to annual doses from natural background radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 2×
“However, note that any risk estimates need to take into account patient demographics, with large differences in the risks per unit effective dose between infants and older adults [8].”
BackgroundMethod
Cited by
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Self-citationProjected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT
Manduca, A., Yu, L., Trzasko, J. D., Khaylova, N., Kofler, J. M., McCollough, C. M., & Fletcher, J. G. (2009) · Medical Physics · doi:10.1118/1.3232004 · Cited by 360
Metadata
- Authors
- Huda, W., & Vance, A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2007-02
- Volume
- 188
- Issue
- 2
- Pages
- 540-546
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2126577566
- Cited by
- 251
- References
- 1
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient Radiation Doses from Adult and Pediatric CT. https://app.cochat.ai/papers/10.2214/ajr.06.0101
- The paper
- Huda, W., & Vance, A. (2007). Patient Radiation Doses from Adult and Pediatric CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.06.0101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.