Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 213

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results

Open access
Cova, M, Squillaci, E, Stacul, F, Manenti, G, Gava, S, Simonetti, G, Pozzi-Mucelli, R · 2004 · The British Journal of Radiology

Abstract

The purpose of this study was to evaluate the capability and the reliability of diffusion-weighted MRI in the evaluation of normal kidney and different renal lesions. 39 patients (10 normal volunteers and 29 patients with known renal lesions) underwent MRI of the kidneys by using a 1.5 T superconducting magnet. Axial fat suppressed turbo spin echo (TSE) T(2) and coronal fast field echo (FFE) T(1) or TSE T(1) weighted images were acquired for each patient. Diffusion-weighted (DW) images were obtained in the axial plane during breath-hold (17 s) with a spin-echo echo planar imaging (SE EPI) single shot sequence (repetition time (TR)=2883 ms, echo time (TE)=61 ms, flip angle=90 degrees ), with b value of 500 s mm(-2). 16 slices were produced with slice thickness of 7 mm and interslice gap of 1 mm. An apparent diffusion coefficient (ADC) map was obtained at each slice position. The ADC was measured in an approximately 1 cm region of interest (ROI) within the normal renal parenchyma, the detected renal lesions and the collecting system if dilated. ADC values in normal renal parenchyma ranged from 1.72 x 10(-3) mm(2) s(-1) to 2.65 x 10(-3) mm(2) s(-1), while ADC values in simple cysts (n=13) were higher (2.87 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1)). In hydronephrotic kidneys (n=6) the ADC values of renal pelvis ranged from 3.39 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1). In cases of pyonephrosis (n=3) ADC values of the renal pelvis were found to be lower than those of renal pelvis of hydronephrotic kidneys (0.77 x 10(-3) mm(2) s(-1) to 1.07 x 10(-3) mm(2) s(-1)). Solid benign and malignant renal tumours (n=7) showed ADC values ranging between 1.28 x 10(-3) mm(2) s(-1) and 1.83 x 10(-3) mm(2) s(-1). In conclusion diffusion-weighted MR imaging of the kidney seems to be a reliable way to differentiate normal renal parenchyma and different renal diseases. Clinical experience with this method is still preliminary and further studies are required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr/26525081

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 213

Metadata

Authors
Cova, M., Squillaci, E., Stacul, F., Manenti, G., Gava, S., Simonetti, G., & Pozzi-Mucelli, R.
Venue
The British Journal of Radiology
Published
2004-10
Volume
77
Issue
922
Pages
851-857
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2168854166
Cited by
213
References
2
FWCI
6.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results. https://app.cochat.ai/papers/10.1259/bjr/26525081
The paper
Cova, M., Squillaci, E., Stacul, F., Manenti, G., Gava, S., Simonetti, G., & Pozzi-Mucelli, R. (2004). Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results. The British Journal of Radiology. https://doi.org/10.1259/bjr/26525081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.