The DOI matches its Crossref record.
Molecular imaging using hyperpolarized 13C
Abstract
MRI provides unsurpassed soft tissue contrast, but the inherent low sensitivity of this modality has limited the clinical use to imaging of water protons. With hyperpolarization techniques, the signal from a given number of nuclear spins can be raised more than 100 000 times. The strong signal enhancement enables imaging of nuclei other than protons, e.g. 13C and 15N, and their molecular distribution in vivo can be visualized in a clinically relevant time window. This article reviews different hyperpolarization techniques and some of the many application areas. As an example, experiments are presented where hyperpolarized 13C nuclei have been injected into rabbits, followed by rapid 13C MRI with high spatial resolution (scan time <1 s and 1.0 mm in-plane resolution). The high degree of polarization thus enabled mapping of the molecular distribution within various organs, a few seconds after injection. The hyperpolarized 13C MRI technique allows a selective identification of the molecules that give rise to the MR signal, offering direct molecular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Albers, M. J., Bok, R., Chen, A. P., Cunningham, C. H., Zierhut, M. L., Zhang, V. Y., Kohler, S. J., Tropp, J., Hurd, R. E., Yen, Y.-F., et al. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-0749 · Cited by 520
The theory and practice of hyperpolarization in magnetic resonance using parahydrogen
Green, R. A., Adams, R. W., Duckett, S. B., Mewis, R. E., Williamson, D. C., & Green, G. G. R. (2012) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2012.03.001 · Cited by 381
Plathow, C., & Weber, W. A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045930 · Cited by 328
Granlund, K. L., Tee, S.-S., Vargas, H. A., Lyashchenko, S. K., Reznik, E., Fine, S., Laudone, V., Eastham, J. A., Touijer, K. A., Reuter, V. E., et al. (2020) · Cell Metabolism · doi:10.1016/j.cmet.2019.08.024 · Cited by 138
Hall, H., Cuellar-Baena, S., Dahlberg, C., in’t Zandt, R., Denisov, V., & Kirik, D. (2011) · Current Topics in Behavioral Neurosciences · doi:10.1007/7854_2011_166 · Cited by 17
Metadata
- Authors
- Golman, K., Olsson, L. E., Axelsson, O., Månsson, S., Karlsson, M., & Petersson, J. S.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-12-01
- Volume
- 76
- Issue
- suppl_2
- Pages
- S118-S127
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2147460776
- Cited by
- 184
- References
- 0
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular imaging using hyperpolarized 13C. https://app.cochat.ai/papers/10.1259/bjr/26631666
- The paper
- Golman, K., Olsson, L. E., Axelsson, O., Månsson, S., Karlsson, M., & Petersson, J. S. (2003). Molecular imaging using hyperpolarized 13C. The British Journal of Radiology. https://doi.org/10.1259/bjr/26631666
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.