The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b = 0, b = 20, b = 300, b = 800 s mm(-2)) and single-shot T2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with special interest in small (<10 mm) lesions. Twenty-four patients underwent routine MRI. The five sequences were compared qualitatively for image quality, lesion conspicuity and artefacts. Quantitative analysis was performed for lesion identification and lesion-to-liver contrast-to-noise ratio (CNR). Subgroup analyses were performed for different types of lesions with different sizes. Sequences were compared by rank order statistic (RIDIT) and Kruskal-Wallis test. The best image quality (p<0.05) was achieved with T2W TSE and the best lesion conspicuity (p<0.05) with T2W TSE for biliary cysts and SE-EPI diffusion-weighted imaging (DWI) (b = 20 s mm(-2)) for haemangiomas and metastases. Image artefacts were lowest (p<0.05) with T2W TSE. T2W TSE was found to be the best protocol (p<0.05) for the identification of biliary cysts and SE-EPI DWI (b = 20 s mm(-2)) for haemangiomas and metastases. The lesion-to-liver CNRs were highest on T2W TSE for biliary cysts and on SE-EPI diffusion-weighted imaging (DWI) for haemangiomas and metastases (p<0.05). This study shows the potential of SS SE-EPI DWI (especially with a b-value of 20 s mm(-2)) as a promising technique for detecting small (<10 mm) focal liver lesions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diffusion-weighted imaging may help to distinguish well-differentiated hepatocellular carcinomas from benign nodules [17,18], C Dionisi Vici and L Monti unpublished.”
From Recommendations for the management of tyrosinaemia type 1 (2013) · cites this paper as [17]
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Bross, I. D. J. (1958) · Biometrics · doi:10.2307/2527727 · Cited by 635
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Goldberg, M. A., Hahn, P. F., Saini, S., Cohen, M. S., Reimer, P., Brady, T. J., & Mueller, P. R. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.5.8470568 · Cited by 95
T2-weighted MR Imaging in the Assessment of Cirrhotic Liver
Hussain, H. K., Syed, I. I., Nghiem, H. V., Johnson, T. D., Carlos, R. C., Weadock, W. J., & Francis, I. R. (2004) · Radiology · doi:10.1148/radiol.2303020921 · Cited by 91
Echo-planar imaging of the liver with a standard MR imaging system.
Butts, K., Riederer, S. J., Ehman, R. L., Felmlee, J. P., & Grimm, R. C. (1993) · Radiology · doi:10.1148/radiology.189.1.8396785 · Cited by 89
Okada, Y., Ohtomo, K., Kiryu, S., & Sasaki, Y. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199805000-00005 · Cited by 85
Hussain, S. M., De Becker, J., Hop, W. C. J., Dwarkasing, S., & Wielopolski, P. A. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20269 · Cited by 83
Cited by
Items 101–149 of 149
Ozaki, K., Ishida, S., Higuchi, S., Sakai, T., Kitano, A., Takata, K., Kinoshita, K., Matta, Y., Ohtani, T., Kimura, H., et al. (2022) · World Journal of Radiology · doi:10.4329/wjr.v14.i10.352 · Cited by 8
Chlorogiannis, D., Moussa, A. M., Zhao, K., Alexander, E. S., Sofocleous, C. T., & Sotirchos, V. S. (2024) · Diagnostics · doi:10.3390/diagnostics14070772 · Cited by 8
Makhija, N., Vikram, N. K., Srivastava, D. N., & Madhusudhan, K. S. (2021) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2021.02.008 · Cited by 8
Difusión en resonancia magnética en el estudio de lesiones hepáticas
Desviat, P. V., de Vega, V. M., Rodríguez, M. R., de la Peña, M. J., & Arranz, J. C. (2011) · Cirugía Española · doi:10.1016/j.ciresp.2011.10.006 · Cited by 8
Diffusion MRI in the Study of Hepatic Lesions
Desviat, P. V., de Vega, V. M., Rodríguez, M. R., de la Peña, M. J., & Arranz, J. C. (2013) · Cirugía Española (English Edition) · doi:10.1016/j.cireng.2011.10.001 · Cited by 8
Fukukura, Y., Kamiyama, T., Takumi, K., Shindo, T., Higashi, R., & Nakajo, M. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22098 · Cited by 8
IRM fonctionnelle corps entier : applications hématologiques
Luciani, A., Lin, C., Beaussart, P., Zerbib, P., Haïoun, C., & Rahmouni, A. (2010) · Journal de Radiologie · doi:10.1016/s0221-0363(10)70053-6 · Cited by 7
“Cependant, le long train d’échos généré par les séquences en EPI se traduit généralement par une importante chute de signal suivant une courbe de dégradation T2* (35-38).”
Schieda, N., Dandan, O. S. A., El‐Khodary, M., & Shabana, W. M. (2014) · Clinical Radiology · doi:10.1016/j.crad.2014.06.017 · Cited by 7
Woeste, M. R., Geller, A. E., Martin, R. C. G., & Polk, H. C. (2021) · Annals of Surgical Oncology · doi:10.1245/s10434-020-09414-5 · Cited by 7
Modern Imaging Evaluation of the Liver
de Souza, D. A. T., Parente, D. B., de Araújo, A. L. E., & Mortelé, K. J. (2013) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2013.01.001 · Cited by 6
Liang, X., Bi, Z., Yang, C., Sheng, R., Xia, X., Zhang, Z., Dai, Y., & Zeng, M. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.918173 · Cited by 6
Hicks, R. M., Loening, A. M., Ohliger, M. A., Vasanawala, S. S., & Hope, T. A. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1252-y · Cited by 6
“with the equation (SIlesion SIliver)/SD, where SIlesion and SIliver are the respective signal intensities of the lesion and liver and SD is the standard deviation of the signal intensity in the adjacent liver [20, 21].”
MethodDeng, J., Jin, N., Yin, X., Yang, G., Zhang, Z., Omary, R. A., & Larson, A. C. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22138 · Cited by 6
Diffusion-weighted MRI of the liver
Taouli, B. A., & Koh, D. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511778070.003 · Cited by 6
Perfusion-and diffusion-weighted imaging of hepatocellular carcinoma.
Vandecaveye, V., Keyzer, F. D., & Dymarkowski, S. (2007) · PubMed · Cited by 5
He, X., Li, Y., Han, D., Zhou, Y., Zhang, J., Xu, Q., Shi, F., Liu, P., Hu, H., & Zhang, L. (2024) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-24-941 · Cited by 4
Bode, M., Zhang, S., Terwolbeck, M. N., Tabrizi, C. M., Sprenger, P., Yoneyama, M., Kraemer, N. A., Kuhl, C. K., & Barabasch, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-16324-x · Cited by 4
Diffusion-Weighted Imaging with Two Different b -Values in Detection of Solid Focal Liver Lesions
Yang, D., Wang, K., Yao, X., Ye, H., Jiang, T., Liu, Y., Gao, J., Chen, M., Zhou, C., & Yang, Z. (2016) · BioMed Research International · doi:10.1155/2016/8128207 · Cited by 4
Overview of Functional MR, CT, and US Imaging Techniques in Clinical Use
Kluza, E., Lambregts, D. M. J., & Beets‐Tan, R. G. H. (2013) · Springer eBooks · doi:10.1007/978-3-642-40412-2_13 · Cited by 3
Khorram, F.-S., Faeghi, F., Jafarisepehr, A., & Farshidfar, Z. (2018) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2018.04.026 · Cited by 3
Iwanaga, T., Fukukura, Y., Saito, T., Sasaki, M., Kumagae, Y., Takumi, K., Hakamada, H., Fujisaki, T., Saigo, Y., & Yoshiura, T. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26196 · Cited by 3
Van, A. T., McTavish, S., Peeters, J., Weiss, K., Makowski, M. R., Braren, R., & Karampinos, D. C. (2024) · NMR in Biomedicine · doi:10.1002/nbm.5147 · Cited by 2
Matsushima, M., Naganawa, S., Ikeda, M., Itoh, S., Ogawa, H., Komada, T., Ishigaki, S., Kawai, H., Suzuki, K., Satake, H., et al. (2010) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.9.49 · Cited by 2
Chen, G.-Y., & Li, Z. (2022) · PubMed Central · doi:10.12182/20220960205 · Cited by 1
Diffusion-Weighted Imaging of the Liver
Muhi, A., Ichikawa, T., & Motosugi, U. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8498-1_10 · Cited by 1
Ali, M. T., Osman, M. F., Homos, M. D., & Nabil, D. M. (2016) · The Egyptian Journal of Radiology and Nuclear Medicine · doi:10.1016/j.ejrnm.2016.08.007 · Cited by 1
3-T Magnetic Resonance Diffusion-Weighted Imaging (DWI) for Characterization of Hepatic Masses
Abdulghaffara, W., Nasr, M., Shahin, W. A., El-Tantawy, A., & Akl, T. H. (2017) · OMICS Journal of Radiology · doi:10.4172/2167-7964.1000249 · Cited by 1
“DWI is more sensitive than T2-weighted sequences [6-9] and than different super paramagnetic iron oxide, enhanced MR studies in the detection and accurate characterization of liver lesions [10].”
BackgroundLewis, S. C., & Taouli, B. A. (2013) · Springer eBooks · doi:10.1007/978-3-642-13327-5_191 · Cited by 1
Luna, A., Cunha, G. M., Sánchez, R. S., & Rodríguez-Fernández, A. (2013) · Springer eBooks · doi:10.1007/978-3-642-40582-2_16 · Cited by 1
MR-Diffusionsbildgebung im Abdomen und Becken
Chuck, N. C., & Boss, A. (2012) · Springer eBooks · doi:10.1007/978-3-642-25340-9_2 · Cited by 1
Diffusion-weighted MRI techniques for the evaluation of focal hepatic lesions
Kocakoç, E., Onur, M. R., & Serter, A. (2012) · Imaging in Medicine · doi:10.2217/iim.12.48 · Cited by 2
Can quantified diffusion-weighted imaging predict histopathological features of liver tumors?
Metens, T. (2023) · European Radiology · doi:10.1007/s00330-023-09791-x · Cited by 1
“Diffusion-weighted imaging (DWI) of the liver is used for lesion detection with low b values (b < 150 s/mm2) as “black blood” fat-suppressed T2-weighted sequence [1].”
MethodOptimization of PROPELLER Methods for Quantitative MRI of Liver Cancer
Deng, J. (2008) · Arch · doi:10.21985/n2qt7z
Further considerations on hepatic lesion discrimination using diffusion MR imaging
Liu, Z., & Zhang, J. (2015) · Tumor Biology · doi:10.1007/s13277-015-4146-z
“First, it is known that DW MR imaging can be used to improve the detection and characterization of hepatic lesions [2].”
BackgroundUpdate and current status of diffusion-weighted MRI in anorectal malignancy
Kaye, T. L., & Tolan, D. J. M. (2015) · Colorectal Cancer · doi:10.2217/crc.15.17
Filipe, J. P. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Role of Functional MRI in the Management of Liver Metastases
Bittencourt, L. K., de Oliveira, R. V., & Taouli, B. A. (2013) · Springer eBooks · doi:10.1007/978-3-642-40582-2_18
Staging of liver metastases with MRI in oncological treatment planning.
Coenegrachts, K., & Rigauts, H. (2007)
Self-citationed Imaging of the Liver Techniques and Applications
Lewis, S. C., Dyvorne, H., Cui, Y., & Taouli, B. A. (2014)
Truica, L. (2011) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2011-09610
PET/CT imaging in colorectal carcinoma
Boktor, R. R., Lee, S. T., & Scott, A. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822960-6.00033-8
Tachikawa, Y., Hamano, H., Chiwata, N., Yoshikai, H., Ikeda, K., Maki, Y., Takahashi, Y., & Koike, M. (2024) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-024-01150-1
Tumor Ablation in the Treatment Paradigm for Colorectal Liver Metastatic Disease
Chlorogiannis, D., Sotirchos, V. S., Petre, E. N., & Sofocleous, C. T. (2026) · Springer eBooks · doi:10.1007/978-3-032-14152-1_4
18F-FAPI-42 PET/MR for the Evaluation of Small (≤3 cm) Hepatic Lesions: A Preliminary Study
Yang, Y. S., Wang, D., Zhou, B., Huang, X., Xia, R., Luo, Y., Sun, J., Li, X., & Chen, X. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.04.047
Cancer du côlon : diagnostic, bilan d’extension
Mariani, A., Cazelles, A., Gallois, C., Jeay, M., Manceau, G., Cadi, M., Saltel-Fulero, A., Taïeb, J., & Karoui, M. (2026) · EMC - Gastro-entérologie · doi:10.1016/s1155-1968(25)41963-4
Liver Diffusion Weighted MRI: Effect of Iron Overload on Apparent Diffusion Coefficient
Meloni, A., Missere, M., Positano, V., Pistoia, L., Santodirocco, M., Serra, M., Roberti, M. G., Renni, R., Sallustio, G., Clemente, A., et al. (2026) · NMR in Biomedicine · doi:10.1002/nbm.70351
Metadata
- Authors
- Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-07
- Volume
- 80
- Issue
- 955
- Pages
- 524-531
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1966369454
- Cited by
- 149
- References
- 20
- Citations by year
- 2026: 4 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 5 · 2017: 5 · 2016: 8 · 2015: 9 · 2014: 10 · 2013: 18 · 2012: 20
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Radiology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- focal liver lesions, diffusion-weighted imaging, fast spin echo, T2-weighted imaging, small liver lesions, b-value, lesion conspicuity, contrast-to-noise ratio, biliary cysts, hepatic hemangioma, liver metastasis, image artifacts
- MeSH terms
- Aged, Bile Duct Diseases, Cysts, Female, Hemangioma, Humans, Image Interpretation, Computer-Assisted, Liver, Liver Diseases, Liver Neoplasms, Male, Middle Aged, Probability, Statistics as Topic, Artifacts, Echo-Planar Imaging, Diffusion Magnetic Resonance Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.