The DOI matches its Crossref record.
Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging
Abstract
Several aspects of blipped echo‐planar imaging (EPI) are treated mathematically. An expression relating the necessary readout gradient strength and sampling time to the spatial resolution and readout duration is derived. It is shown how the net spatial resolution may be limited by the object's T2 characteristics and Bo field homogeneity, irrespective of the number of sampled points. Additionally, off‐resonance effects result in a loss of spatial resolution and image distortion to a considerably greater degree than in conventional two‐dimensional Fourier transform imaging. The extent of these effects is directly related to the time required to acquire the data matrix, and is therefore amplified when EPI is implemented on a standard commercial whole‐body system which because of limited gradient performance uses necessarily longer sampling durations. Specific hardware modifications to a standard commercial imager are considered to allow successful EPI implementation. EPI image characteristics are compared quantitatively with those of conventional methods. © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The human amygdala and the emotional evaluation of sensory stimuli
Zald, D. H. (2003) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00248-5 · Cited by 1,062
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationFunctional neuroimaging of the olfactory system in humans
Zald, D. H., & Pardo, J. V. (2000) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(99)00110-5 · Cited by 334
Magnetic field changes in the human brain due to swallowing or speaking
Birn, R. M., Bandettini, P. A., Cox, R. W., Jesmanowicz, A., & Shaker, R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400108 · Cited by 172
Metadata
- Authors
- Farzaneh, F., Riederer, S. J., & Pelc, N. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 14
- Issue
- 1
- Pages
- 123-139
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2028564515
- Cited by
- 362
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging. https://app.cochat.ai/papers/10.1002/mrm.1910140112
- The paper
- Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990). Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910140112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.