Ultrasound elastography for musculoskeletal applications
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Ultrasound elastography (EUS) is a method to assess the mechanical properties of tissue, by applying stress and detecting tissue displacement using ultrasound. There are several EUS techniques used in clinical practice; strain (compression) EUS is the most common technique that allows real-time visualisation of the elastographic map on the screen. There is increasing evidence that EUS can be used to measure the mechanical properties of musculoskeletal tissue in clinical practice, with the future potential for early diagnosis to both guide and monitor therapy. This review describes the various EUS techniques available for clinical use, presents the published evidence on musculoskeletal applications of EUS and discusses the technical issues, limitations and future perspectives of this method in the assessment of the musculoskeletal system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Gennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
Sikdar, S., Shah, J. P., Gebreab, T., Yen, R.-H., Gilliams, E., Danoff, J., & Gerber, L. H. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.04.015 · Cited by 362
Real-Time Elastography for Noninvasive Assessment of Liver Fibrosis in Chronic Viral Hepatitis
Friedrich-Rust, M., Ong, M.-F., Herrmann, E., Dries, V., Samaras, P., Zeuzem, S., & Sarrazin, C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0322 · Cited by 325
Janssen, J., Schlörer, E., & Greiner, L. (2007) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.12.057 · Cited by 275
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2009) · Clinical Radiology · doi:10.1016/j.crad.2009.08.006 · Cited by 230
Self-citationDe Zordo, T., Lill, S. R., Fink, C., Feuchtner, G. M., Jaschke, W., Bellmann-Weiler, R., & Klauser, A. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2020 · Cited by 214
De Zordo, T., Chhem, R., Smekal, V., Feuchtner, G., Reindl, M., Fink, C., Faschingbauer, R., Jaschke, W., & Klauser, A. (2009) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0028-1109809 · Cited by 211
Sonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203
Real-Time Sonoelastography Findings in Healthy Achilles Tendons
De Zordo, T., Fink, C., Feuchtner, G. M., Smekal, V., Reindl, M., & Klauser, A. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1843 · Cited by 195
Real‐time elastography for detecting prostate cancer: preliminary experience
Pallwein, L., Mitterberger, M., Struve, P., Pinggera, G., Horninger, W., Bartsch, G., Aigner, F., Lorenz, A., Pedross, F., & Frauscher, F. (2007) · BJU International · doi:10.1111/j.1464-410x.2007.06851.x · Cited by 179
AAPM/RSNA Physics Tutorial for Residents: Topics in US
Hall, T. J. (2003) · Radiographics · doi:10.1148/rg.236035163 · Cited by 152
Is Sonoelastography of Value in Assessing Tendons?
Klauser, A. S., Faschingbauer, R., & Jaschke, W. R. (2010) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-0030-1254521 · Cited by 147
Săftoiu, A., Vilmann, P., Hassan, H. A., & Gorunescu, F. (2006) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2006-927117 · Cited by 143
Muscle hardness measurement by using ultrasound elastography: a feasibility study
Niitsu, M., Michizaki, A., Endo, A., TAKEI, H., & Yanagisawa, O. (2011) · Acta Radiologica · doi:10.1258/ar.2010.100190 · Cited by 140
Goertz, R., Zopf, Y., Jugl, V., Heide, R., Janson, C., Strobel, D. D., Bernatik, T., & Haendl, T. (2010) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0029-1245244 · Cited by 132
Nordez, A., Gennisson, J., Casari, P., Catheline, S., & Cornu, C. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.033 · Cited by 124
Friedrich‐Rust, M., Romenski, O., Meyer, G., Dauth, N., Holzer, K., Grünwald, F., Kriener, S., Herrmann, E. M., Zeuzem, S., & Bojunga, J. (2011) · Ultrasonics · doi:10.1016/j.ultras.2011.06.012 · Cited by 115
Passive in vivo elastography from skeletal muscle noise
Sabra, K. G., Conti, S., Roux, P., & Kuperman, W. A. (2007) · Applied Physics Letters · doi:10.1063/1.2737358 · Cited by 106
Drakonaki, E. E., & Allen, G. M. (2010) · Skeletal Radiology · doi:10.1007/s00256-009-0861-0 · Cited by 88
Self-citation
Cited by
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citationShear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017) · RadioGraphics · doi:10.1148/rg.2017160116 · Cited by 729
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness
Brandenburg, J. E., Eby, S. F., Song, P., Zhao, H., Brault, J. S., Chen, S., & An, K.-N. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.07.007 · Cited by 327
Metadata
- Authors
- Drakonaki, E. E., Allen, G. M., & Wilson, D. J.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-11-01
- Volume
- 85
- Issue
- 1019
- Pages
- 1435-1445
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2130400238
- Cited by
- 385
- References
- 25
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.