Technical aspects of dental CBCT: state of the art
Open accessAbstract
As CBCT is widely used in dental and maxillofacial imaging, it is important for users as well as referring practitioners to understand the basic concepts of this imaging modality. This review covers the technical aspects of each part of the CBCT imaging chain. First, an overview is given of the hardware of a CBCT device. The principles of cone beam image acquisition and image reconstruction are described. Optimization of imaging protocols in CBCT is briefly discussed. Finally, basic and advanced visualization methods are illustrated. Certain topics in these review are applicable to all types of radiographic imaging (e.g. the principle and properties of an X-ray tube), others are specific for dental CBCT imaging (e.g. advanced visualization techniques).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
2007 Recommendations of the International Commission on Radiological Protection
Publ., I. (2008) · Annals of the ICRP · Cited by 1,788
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
Mozzo, P., Procacci, C., Tacconi, A., Tinazzi Martini, P., & Bergamo Andreis, I. A. (1998) · European Radiology · doi:10.1007/s003300050586 · Cited by 1,383
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
A generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Birch, R., & Marshall, M. (1979) · Physics in Medicine & Biology · doi:10.1088/0031-9155/24/3/002 · Cited by 512
The Essential Physics of Medical Imaging
Talib, Z. H. J., Alzahra, F. H. A., Al-Mamoori, R. B. M., & Jassim, A. S. M. (2024) · Bright Sky Publications eBooks · doi:10.62906/bs.book.174 · Cited by 352
Statistical Image Reconstruction Methods for Transmission Tomography
Fessler, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch1 · Cited by 240
A geometric calibration method for cone beam CT systems
Yang, K., Kwan, A. L. C., Miller, D. F., & Boone, J. M. (2006) · Medical Physics · doi:10.1118/1.2198187 · Cited by 217
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.12.007 · Cited by 185
Iterative correction of beam hardening artifacts in CT
Gompel, G. V., Slambrouck, K. V., Defrise, M., Batenburg, K. J., Mey, J. D., Sijbers, J., & Nuyts, J. L. (2011) · Medical Physics · doi:10.1118/1.3577758 · Cited by 151
Schäfer, S., Nithiananthan, S., Mirota, D. J., Uneri, A., Stayman, J. W., Zbijewski, W. B., Schmidgunst, C., Kleinszig, G., Khanna, A. J., & Siewerdsen, J. H. (2011) · Medical Physics · doi:10.1118/1.3597566 · Cited by 134
Self-citationApplications of CBCT in dental practice: a review of the literature.
Alamri, H. M., Sadrameli, M., Alshalhoob, M. A., Sadrameli, M., & Alshehri, M. A. (2012) · PubMed · Cited by 130
Pauwels, R., Zhang, G., Theodorakou, C., Walker, A., Bosmans, H., Jacobs, R., Bogaerts, R., & Horner, K. (2014) · British Journal of Radiology · doi:10.1259/bjr.20130654 · Cited by 101
Self-citationTransmission maximum-likelihood reconstruction with ordered subsets for cone beam CT
Manglos, S. H., Gagne, G., Król, A., Thomas, F. D., & Narayanaswamy, R. A. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/7/006 · Cited by 94
Geometric calibration of a mobile C‐arm for intraoperative cone‐beam CT
Daly, M. J., Siewerdsen, J. H., Cho, Y. B., Jaffray, D. A., & Irish, J. C. (2008) · Medical Physics · doi:10.1118/1.2907563 · Cited by 90
Self-citationLennon, S., Patel, S., Foschi, F., Wilson, R. F., Davies, J., & Mannocci, F. (2011) · International Endodontic Journal · doi:10.1111/j.1365-2591.2011.01930.x · Cited by 73
Xu, J., Reh, D. D., Carey, J. P., Mahesh, M., & Siewerdsen, J. H. (2012) · Medical Physics · doi:10.1118/1.4736805 · Cited by 59
Self-citationDevelopments with maximum likelihood X-ray computed tomography
Browne, J. A., & Holmes, T. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.126909 · Cited by 36
Cited by
Cone beam computed tomography in implant dentistry: recommendations for clinical use
Jacobs, R., Salmon, B., Codari, M., Hassan, B., & Bornstein, M. M. (2018) · BMC Oral Health · doi:10.1186/s12903-018-0523-5 · Cited by 521
An overview of deep learning in the field of dentistry
Hwang, J.-J., Jung, Y.-H., Cho, B.-H., & Heo, M.-S. (2019) · Imaging Science in Dentistry · doi:10.5624/isd.2019.49.1.1 · Cited by 296
Temporomandibular joint segmentation in MRI images using deep learning
Li, M., Punithakumar, K., Major, P. W., Le, L. H., Nguyen, K.-C. T., Pacheco-Pereira, C., Kaipatur, N. R., Nebbe, B., Jaremko, J. L., & Almeida, F. T. (2022) · Journal of Dentistry · doi:10.1016/j.jdent.2022.104345 · Cited by 55
Metadata
- Authors
- Pauwels, R., Araki, K., Siewerdsen, J. H., & Thongvigitmanee, S. S.
- Venue
- Dentomaxillofacial Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-01
- Volume
- 44
- Issue
- 1
- Pages
- 20140224
- ISSN
- 0250-832X (ISSN-L)
- 1476-542X
- OpenAlex
- W1984025056
- Cited by
- 510
- References
- 27
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.