Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

Geometric accuracy of the NewTom 9000 Cone Beam CT

Marmulla, R, Wörtche, R, Mühling, J, Hassfeld, S · 2005 · Dentomaxillofacial Radiology

Abstract

OBJECTIVES: To determine the geometric accuracy of digital volume tomograms to assess their usability for implant planning. METHODS: A measuring object with 216 measuring points, whose geometry is exactly known, is X-rayed with a NewTom 9000 cone beam scanner; thereafter the geometry of the volume tomogram of the object is compared with the original body. RESULTS: Considering all three coordinate axes, geometric mean deviations of 0.13 +/- 0.09 mm with a maximum deviation of 0.3 mm were determined. These geometric deviations are below the resolution power of the volume tomograph. CONCLUSION: The digital volume tomographies of NewTom 9000 present images which are geometrically correct and, from a geometrical point of view, suitable for three-dimensional implant planning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/dmfr/31342245

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Marmulla, R., Wörtche, R., Mühling, J., & Hassfeld, S.
Venue
Dentomaxillofacial Radiology
Published
2005-01
Volume
34
Issue
1
Pages
28-31
ISSN
  • 0250-832X (ISSN-L)
  • 1476-542X
OpenAlex
W2154324001
Cited by
230
References
0
FWCI
16.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Geometric accuracy of the NewTom 9000 Cone Beam CT. https://app.cochat.ai/papers/10.1259/dmfr/31342245
The paper
Marmulla, R., Wörtche, R., Mühling, J., & Hassfeld, S. (2005). Geometric accuracy of the NewTom 9000 Cone Beam CT. Dentomaxillofacial Radiology. https://doi.org/10.1259/dmfr/31342245

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.