The DOI matches its Crossref record.
Novel FAD-Dependent Glucose Dehydrogenase for a Dioxygen-Insensitive Glucose Biosensor
Open accessAbstract
A novel FAD-dependent glucose dehydrogenase (FAD-GDH) was found and its enzymatic property for glucose sensing was characterized. FAD-GDH oxidized glucose in the presence of some artificial electron acceptors, except for O2, and exhibited thermostability, high substrate specificity and a large Michaelis constant for glucose. FAD-GDH was applied to an amperometric glucose sensor with Fe(CN)6(3-) as a soluble mediator. The use of a relatively high concentration of Fe(CN)6(3-) resulted in a good linearity between the current response and the glucose concentration, taking into account a large Michaelis constant for Fe(CN)6(3-). The glucose sensor was completely insensitive to O2 and responded linearly to glucose up to 30 mM. Compared to glucose, the response to other saccharides was negligible. The sensor can be stored at room temperature in a desiccator for at least one month without any change in the response or activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Tackling the Challenges of Enzymatic (Bio)Fuel Cells
Xiao, X., Xia, H.-Q., Wu, R., Bai, L., Yan, L., Magner, E., Cosnier, S., Lojou, E., Zhu, Z., & Liu, A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00115 · Cited by 504
Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird's Eye View of Glucose Sensing Enzymes
Ferri, S., Kojima, K., & Sode, K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500507 · Cited by 471
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Glucose: Detection and analysis
Galant, A. L., Kaufman, R. C., & Wilson, J. D. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.04.071 · Cited by 350
Evaluation of commercial glucometer test strips for potential measurement of glucose in tears
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E. (2014) · Analytical Chemistry · doi:10.1021/ac4040168 · Cited by 67
Huang, T.-Y., Chang, H.-W., Tsao, M.-F., Chuang, S.-M., Ni, C.-C., Sue, J.-W., Lin, H.-C., & Hsu, C.-T. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.02.023 · Cited by 15
Metadata
- Authors
- TSUJIMURA, S., KOJIMA, S., KANO, K., IKEDA, T., SATO, M., SANADA, H., & OMURA, H.
- Venue
- Bioscience, Biotechnology, and Biochemistry
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 70
- Issue
- 3
- Pages
- 654-659
- ISSN
- 0916-8451 (ISSN-L)
- 1347-6947
- OpenAlex
- W2089375295
- Cited by
- 175
- References
- 0
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.